← Back
One family attached or semi-detached
199-05 24 ROAD
QUEENS · BIN 4129858
💬 Discuss this project
1940Year Built
1Stories
A5Building Class
R2AZoning
946 sfGross Floor Area
1Units
One family attached or semi-detached · 2,142 sf lot · 0.44 FAR built · Flood zone X
Locations of Work
Architecture
Roof1p · 1 filing · 9 docs
1 job · most recent 11/13/2025
FiledStatusContractorScope
11/13/2025CompleteACCORD POWER ELECTRIC LLC—
Building Lifecycle
All (8)Filed (1)Permit Issued (1)Signed Off (1)Special Inspection (5)
03/13/2026
Signed off — Alteration
Installation of 5.72 kw solar energy system on roof. No change of occupancy, use or egress.
Q01311842-I1
11/13/2025
Permit issued — Solar
Q01311842-I1-SL
11/07/2025
Filed — Alteration
Installation of 5.72 kw solar energy system on roof. No change of occupancy, use or egress.
Q01311842-I1
11/05/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Malathi Ananthakrishnan
11/05/2025
Special inspection requirement — Air barrier - visual inspection
Malathi Ananthakrishnan
10/31/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Malathi Ananthakrishnan
10/31/2025
Special inspection requirement — Energy Code Compliance Inspections
Malathi Ananthakrishnan
10/31/2025
Special inspection requirement — Final
Malathi Ananthakrishnan
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
09/17/2014$532K—Private party → Private party$562/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
SYNERGIC DESIGN ARCHITECTS111/07/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ACCORD POWER INCGeneral Contractor104/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SYNERGIC DESIGN LLC8561111/07/2025
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offACCORD POWER INC11/13/2025
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
11/05/2025Structural Stability – Alterations of existing buildingsMalathi Ananthakrishnanspecial
11/05/2025Air barrier - visual inspectionMalathi Ananthakrishnanenergy_progress
10/31/2025Fire-Resistant Penetrations and JointsMalathi Ananthakrishnanspecial
10/31/2025Energy Code Compliance InspectionsMalathi Ananthakrishnanprogress
10/31/2025FinalMalathi Ananthakrishnanprogress
▾Documents — 9 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/18/2026Q01311842-I1Request digital key ↗
▸Seals & Professional Certifications6
▸DOB NOWProgress Inspector Seal & Signature3
08/22/2026Q01311842-I1Open ↗
08/22/2026Q01311842-I1Open ↗
08/22/2026Q01311842-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/22/2026Q01311842-I1Open ↗
08/22/2026Q01311842-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/18/2026Q01311842-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/18/2026Q01311842-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026Q01311842-I1Open ↗