← Back
Four families
199 NORTH 6 STREET
BROOKLYN · BIN 3062133
💬 Discuss this project
1910Year Built
4Stories
C3Building Class
R6BZoning
3,520 sfGross Floor Area
4Units
Rent Stabilized10 Open Violations 9 unresolved · 1 paperwork only ▸FDNY Report ↗
Four families · Owner of record: 199 N 6TH REALTY LLC · 2,200 sf lot · 1.6 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
BH 112 NORTH 7TH STREET604/09/2026
199 N 6TH REALTY LLC403/22/2026
SAKAB DESIGN103/22/2026
199 N6TH LLC103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
09/29/2023$4.3M—— → —$1,214/sf building
10/20/2022$3.1M—— → —$881/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
H G LEE ARCHITECT PC210/10/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SAKAB DESIGN INCGeneral Contractor104/09/2026
Building Lifecycle
All (25)Filed (2)Permit Issued (1)Violation (20)Objection (2)
05/05/2026
Violation issued (HPD, open)
A
12/29/2025
Violation issued (ECB, closed)
Construction
11/19/2025
Violation issued (HPD, open)
I
11/13/2025
Permit issued — General Construction
B01289921-I1-GC
10/30/2025
Objection raised — Scope
10/30/2025
Objection resolved — Addressed
10/17/2025
Violation issued (ECB, closed)
Construction
10/10/2025
Filed — Alteration
NEW SPLIT AC UNITS INSTALLED ON FIRST AND THIRD FLOOR, REMOVE ECB VIOLATION: 39155712, NO CHANGE IN USE, OCCUPANCY, EGRESS OR BULK.
B01289921-S1
09/30/2025
Filed — Alteration
NEW SPLIT AC UNITS INSTALLED ON FIRST AND THIRD FLOOR, REMOVE ECB VIOLATION: 39155712, NO CHANGE IN USE, OCCUPANCY, EGRESS OR BULK.
B01289921-I1
08/01/2025
Violation issued (ECB, closed)
Construction
08/01/2025
Violation issued (ECB, closed)
Construction
06/10/2025
Violation issued (HPD, open)
A
11/26/2024
Violation issued (HPD, open)
I
04/11/2024
Violation issued (HPD, open)
A
11/17/2023
Violation issued (HPD, open)
I
02/03/2023
Violation issued (ECB, open)
Construction
11/07/2022
Violation issued (HPD, closed)
I
03/01/2022
Violation issued (HPD, closed)
I
03/01/2022
Violation issued (HPD, closed)
A
04/12/2021
Violation issued (HPD, closed)
I
04/12/2021
Violation issued (HPD, closed)
A
10/19/2018
Violation issued (HPD, closed)
I
02/24/1986
Violation issued (HPD, open)
B
08/21/1984
Violation issued (HPD, open)
A
08/21/1984
Violation issued (HPD, open)
B
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedSAKAB DESIGN INC11/13/2025
1 project · most recent 10/10/2025
Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
10/10/2025Permit IssuedSAKAB DESIGN INCAir Conditioning Systems
Cooling
Fujitsu MODEL NUMBER ASUH09LPAS 9,000 BTU · Split System ×6
1 project · most recent 10/19/2025
General Wiring
FiledStatusContractorScope
10/19/2025CompleteLENS ELECTRIC, INCGeneral Wiring
Nothing on file for this building.
▾Documents — 6 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/20/2026B01289921-S1Request digital key ↗
08/20/2026B01289921-I1Request digital key ↗
▸Seals & Professional Certifications2
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/20/2026B01289921-S1Open ↗
08/20/2026B01289921-I1Open ↗
▸Safety & Tenant Protection2
▸DOB NOWHPD-1: Anti-Harassment Area Checklist2
08/13/2026B01289921-I1Open ↗
08/13/2026B01289921-S1Open ↗