← Back
BuildNYC
QUEENS
20-04 154TH STREET
QUEENS · BIN 4625999
💬 Discuss this project
—Year Built
—Stories
—Building Class
—Zoning
—Gross Floor Area
—Units
Locations of Work
ArchitectureStructuralMechanicalCivil
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Permit Issued — active, not yet Signed-off
RoofUnder Construction6p · 1 filing · 20 docs
AtticUnder Construction9p · 1 filing · 20 docs
Floor 2Under Construction9p · 1 filing · 20 docs
Floor 1Under Construction9p · 1 filing · 20 docs
CellarUnder Construction7p · 1 filing · 20 docs
Site & exteriorUnder Construction1 filing · 20 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Mehdi Ghazi, P.E409/14/2026
Mei Architect103/12/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Mei Architect203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
L&L Construction DevelopmentGeneral Contractor408/05/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Mehdi Ghazi, P.E7129409/02/2026
Triangle Inspection & Tes7495109/02/2026
Building Lifecycle
All (40)Filed (5)Permit Issued (4)Objection (1)Special Inspection (30)
09/14/2026
Filed — New Building
NEW 2-STORY BUILDING FOR 2-FAMILY RESIDENCE. OBTAIN A NEW CERTIFICATE OF OCCUPANCY.
Q01367513-S4
09/02/2026
Filed — New Building
NEW 2-STORY BUILDING FOR 2-FAMILY RESIDENCE. OBTAIN A NEW CERTIFICATE OF OCCUPANCY.
Q01367513-S3
08/04/2026
Permit issued — Earth Work
Q01367513-S1-FO-EA
07/30/2026
Permit issued — General Construction
Q01367513-I1-MS
07/30/2026
Permit issued — General Construction
Q01367513-I1-GC
07/29/2026
Permit issued — Structural
Q01367513-S2-ST
07/21/2026
Filed — New Building
NEW 2-STORY BUILDING FOR 2-FAMILY RESIDENCE. OBTAIN A NEW CERTIFICATE OF OCCUPANCY.
Q01367513-S2
07/21/2026
Filed — New Building
NEW 2-STORY BUILDING FOR 2-FAMILY RESIDENCE. OBTAIN A NEW CERTIFICATE OF OCCUPANCY.
Q01367513-S1
07/20/2026
Special inspection requirement — Concrete - Cast-In-Place
MEHDI GHAZI
07/20/2026
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
Rajasekhar Sakhamuri
07/20/2026
Special inspection requirement — Structural Wood Frame
MEHDI GHAZI
07/20/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
MEHDI GHAZI
07/20/2026
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
MEHDI GHAZI
07/20/2026
Special inspection requirement — Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention Facilities
Rajasekhar Sakhamuri
07/20/2026
Special inspection requirement — Sprinkler Systems
MEHDI GHAZI
07/20/2026
Special inspection requirement — Energy Code Compliance Inspections
MEHDI GHAZI
07/20/2026
Special inspection requirement — HVAC-R and service water heating equipment
MEHDI GHAZI
07/20/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
MEHDI GHAZI
07/20/2026
Special inspection requirement — HVAC-R and service water heating system controls
MEHDI GHAZI
07/20/2026
Special inspection requirement — Masonry
MEHDI GHAZI
07/20/2026
Special inspection requirement — Subgrade Inspections
MEHDI GHAZI
07/20/2026
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
MEHDI GHAZI
07/19/2026
Special inspection requirement — Footing and Foundation
MEHDI GHAZI
07/19/2026
Special inspection requirement — Final
MEHDI GHAZI
07/19/2026
Special inspection requirement — Final
MEHDI GHAZI
03/30/2026
Objection raised — Other
03/12/2026
Filed — New Building
NEW 2-STORY BUILDING FOR 2-FAMILY RESIDENCE. OBTAIN A NEW CERTIFICATE OF OCCUPANCY.
Q01367513-I1
03/04/2026
Special inspection requirement — Fire-Resistance Rated Construction
MEHDI GHAZI
03/04/2026
Special inspection requirement — Air barrier — testing
MEHDI GHAZI
03/04/2026
Special inspection requirement — Maintenance information
MEHDI GHAZI
03/04/2026
Special inspection requirement — Air barrier - visual inspection
MEHDI GHAZI
03/04/2026
Special inspection requirement — Duct leakage testing, insulation and design
MEHDI GHAZI
03/04/2026
Special inspection requirement — Electric vehicle service equipment requirements
MEHDI GHAZI
03/04/2026
Special inspection requirement — HVAC-R and service water heating system controls
MEHDI GHAZI
03/04/2026
Special inspection requirement — Metering
MEHDI GHAZI
03/04/2026
Special inspection requirement — Fenestration air leakage
MEHDI GHAZI
03/04/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
MEHDI GHAZI
03/04/2026
Special inspection requirement — Permanent certificate
MEHDI GHAZI
03/04/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
MEHDI GHAZI
03/04/2026
Special inspection requirement — Fenestration areas
MEHDI GHAZI
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWEarth WorkPermit IssuedL&L Construction Development08/04/2026
DOB NOWGeneral ConstructionPermit IssuedL&L Construction Development07/30/2026
DOB NOWGeneral ConstructionPermit IssuedL&L Construction Development07/30/2026
DOB NOWStructuralPermit IssuedL&L Construction Development07/29/2026
1 project · most recent 09/14/2026
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
09/14/2026Permit IssuedL&L Construction DevelopmentHeating and Air Conditioning Systems
Heat / Cool
Mitsubishi Electric MXZ-SM60NL 60,000 BTU · Heat Pump Outdoor ×3
1 project · most recent 09/14/2026
Plumbing-Sprinkler Storm Water/Sanitary
FiledStatusContractorScope
09/14/2026——Plumbing-Sprinkler, Storm, Water/Sanitary
1 project · most recent 09/14/2026
Masonry Wood
FiledStatusContractorScope
09/14/2026Permit IssuedL&L Construction DevelopmentMasonry, Wood
▾Special Inspection Requirements (DOB NOW) — 41
DateRequirementInspectorRole
07/20/2026Concrete - Cast-In-PlaceMEHDI GHAZIspecial
07/20/2026Subsurface Investigations (Borings/Test Pits)Rajasekhar Sakhamurispecial
07/20/2026Structural Wood FrameMEHDI GHAZIprogress
07/20/2026Fire-Resistant Penetrations and JointsMEHDI GHAZIspecial
07/20/2026Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationMEHDI GHAZIspecial
07/20/2026Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention FacilitiesRajasekhar Sakhamurispecial
07/20/2026Sprinkler SystemsMEHDI GHAZIspecial
07/20/2026Energy Code Compliance InspectionsMEHDI GHAZIprogress
07/20/2026HVAC-R and service water heating equipmentMEHDI GHAZIenergy_progress
07/20/2026HVAC-R and service water piping design and insulationMEHDI GHAZIenergy_progress
07/20/2026HVAC-R and service water heating system controlsMEHDI GHAZIenergy_progress
07/20/2026MasonryMEHDI GHAZIspecial
07/20/2026Subgrade InspectionsMEHDI GHAZIspecial
07/20/2026Excavations - Sheeting, Shoring, and BracingMEHDI GHAZIspecial
07/19/2026Footing and FoundationMEHDI GHAZIprogress
07/19/2026FinalMEHDI GHAZIprogress
07/19/2026FinalMEHDI GHAZIprogress
03/04/2026Fire-Resistance Rated ConstructionMEHDI GHAZIprogress
03/04/2026Air barrier — testing MEHDI GHAZIenergy_progress
03/04/2026Maintenance informationMEHDI GHAZIenergy_progress
03/04/2026Air barrier - visual inspectionMEHDI GHAZIenergy_progress
03/04/2026Duct leakage testing, insulation and designMEHDI GHAZIenergy_progress
03/04/2026Electric vehicle service equipment requirementsMEHDI GHAZIenergy_progress
03/04/2026HVAC-R and service water heating system controlsMEHDI GHAZIenergy_progress
03/04/2026MeteringMEHDI GHAZIenergy_progress
Latest 25 of 41.
▾Documents — 31 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/17/2026Q01367513-S2Request digital key ↗
08/17/2026Q01367513-S1Request digital key ↗
08/15/2026Q01367513-I1Request digital key ↗
▸Zoning, Tax Lot & Property Records3
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/15/2026Q01367513-I1Open ↗
▸DOB NOWZoning Exhibit form (1-5)1
08/15/2026Q01367513-I1Open ↗
▸DOB NOWZD1: DOB Zoning Diagram1
08/15/2026Q01367513-I1Open ↗
▸Seals & Professional Certifications15
▸DOB NOWSpecial Inspector Seal & Signature6
09/17/2026Q01367513-I1Open ↗
09/17/2026Q01367513-I1Open ↗
08/25/2026Q01367513-S2Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/17/2026Q01367513-I1Open ↗
08/17/2026Q01367513-S4Open ↗
08/17/2026Q01367513-S3Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWProgress Inspector Seal & Signature4
09/17/2026Q01367513-I1Open ↗
09/17/2026Q01367513-I1Open ↗
08/25/2026Q01367513-S2Open ↗
Showing 3 of 4 on file for this type
▸Safety & Tenant Protection2
▸DOB NOWStreet Tree Checklist1
08/15/2026Q01367513-I1Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/15/2026Q01367513-I1Open ↗
▸Inspections & Test Reports4
▸DOB NOWSOIL REPORT2
08/17/2026Q01367513-S1Open ↗
08/15/2026Q01367513-I1Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram2
08/17/2026Q01367513-S1Open ↗
08/15/2026Q01367513-I1Open ↗
▸Other Documents4
▸DOB NOWSite Survey: Initial1
08/15/2026Q01367513-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/15/2026Q01367513-I1Open ↗
▸DOB NOWAdjoining Owners Notification1
08/17/2026Q01367513-S1Open ↗
▸DOB NOWProperty Ownership Certification1
08/15/2026Q01367513-I1Open ↗