General
Roof1p · 1 filing · 7 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NY BUILDING ASSOCIATES INC107/24/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
S R SOLAR DESIGN203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
CAJO, CARLOSElectrical103/21/2026
GMJ ELECTRIC CORPElectrical103/22/2026
WALTERS, JAMESElectrical103/21/2026
HYTECH SOLAR INCGeneral Contractor104/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NKM ENGINEERING PLLC6244107/24/2025
Building Lifecycle
All (11)Filed (1)Permit Issued (1)Objection (4)Special Inspection (5)
08/26/2025
Permit issued — Solar
Q01238885-I1-SL
08/13/2025
Objection resolved — Addressed
08/08/2025
Objection raised — Fire_Protection
08/05/2025
Objection resolved — Addressed
08/01/2025
Objection raised — Admin
07/24/2025
Filed — Alteration
INSTALLATION OF SOLAR PANELS ON EXISTING ROOF. NO CHANGE IN USE, OCCUPANCY, OR EGRESS. NO CHANGE IN BULK
Q01238885-I1
06/10/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
NARESH MAHANGU
06/10/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
NARESH MAHANGU
06/10/2025
Special inspection requirement — Energy Code Compliance Inspections
NARESH MAHANGU
06/10/2025
Special inspection requirement — Final
NARESH MAHANGU
06/10/2025
Special inspection requirement — Air barrier - visual inspection
NARESH MAHANGU
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offHYTECH SOLAR08/26/2025
1 project · most recent 06/27/2025
FiledStatusContractorScope
06/27/2025CompleteGMJ ELECTRIC CORP—
1 project · most recent 07/24/2025
FiledStatusContractorScope
07/24/2025Signed-offHYTECH SOLAR INC28 panels, 12.04 kw, 443 roof_area_sqft
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
06/10/2025Fire-Resistant Penetrations and JointsNARESH MAHANGUspecial
06/10/2025Structural Stability – Alterations of existing buildingsNARESH MAHANGUspecial
06/10/2025Energy Code Compliance InspectionsNARESH MAHANGUprogress
06/10/2025FinalNARESH MAHANGUprogress
06/10/2025Air barrier - visual inspectionNARESH MAHANGUenergy_progress
▾Documents — 7 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/19/2026Q01238885-I1Request digital key ↗
▸Seals & Professional Certifications4
▸DOB NOWProgress Inspector Seal & Signature2
08/30/2026Q01238885-I1Open ↗
08/30/2026Q01238885-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/19/2026Q01238885-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/30/2026Q01238885-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/19/2026Q01238885-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/19/2026Q01238885-I1Open ↗