← Back
One family attached or semi-detached
20-29 43 STREET
QUEENS · Astoria (North)-Ditmars-Steinway · BIN 4015114
💬 Discuss this project
1940Year Built
2Stories
A5Building Class
R4Zoning
1,440 sfGross Floor Area
1Units
Rent Stabilized0 Open Violations
One family attached or semi-detached · Owner of record: 20-29 43 STREET LLC · 2,000 sf lot · 0.72 FAR built · Flood zone X
Locations of Work
Mechanical
Floor 24p · 1 filing · 6 docs
Floor 14p · 1 filing · 6 docs
Cellar4p · 1 filing · 6 docs
Basement1p · 1 filing · 6 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
01/05/2022$800K—Private party → 20-29 43 STREET LLC$556/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
SIDERIS KEFALAS ENGINEERS PC109/06/2022
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
D.D.S. MECHANICAL PLUMBGeneral Contractor407/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SIDERIS KEFALAS ENGINEERS3434109/06/2022
Building Lifecycle
All (11)Filed (1)Permit Issued (3)Violation (1)Special Inspection (6)
09/09/2024
Permit issued — Mechanical Systems
Q00785106-I1-MS
11/29/2023
Violation issued (HPD, closed)
I
09/15/2023
Permit issued — Mechanical Systems
Q00785106-I1-MS
09/16/2022
Permit issued — Mechanical Systems
Q00785106-I1-MS
09/06/2022
Filed — Alteration
Herewith filing for installation of VRF type HVAC equipment with condensing unit in rear yard. This equipment provides both heating and cooling. No change to use, occupancy, or egress.
Q00785106-I1
09/06/2022
Special inspection requirement — HVAC-R and service water heating equipment
Chris Sideris
09/06/2022
Special inspection requirement — Maintenance information
Chris Sideris
09/06/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
Chris Sideris
09/06/2022
Special inspection requirement — HVAC-R and service water heating system controls
Chris Sideris
08/01/2022
Special inspection requirement — Mechanical Systems
Chris Sideris
08/01/2022
Special inspection requirement — Final
Chris Sideris
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedD.D.S. MECHANICAL PLUMB09/09/2024
DOB NOWMechanical SystemsPermit IssuedD.D.S. MECHANICAL PLUMB09/15/2023
DOB NOWMechanical SystemsPermit IssuedD.D.S. MECHANICAL PLUMB09/16/2022
BISOTISSUEDARMOS 8 RESTORATION INC08/24/2016
1 project · most recent 09/06/2022
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
09/06/2022Permit IssuedD.D.S. MECHANICAL PLUMBHeating and Air Conditioning Systems
Heat / Cool
Mitsubishi Electric PUMY-P48NKMU3 48,000 BTU · Vrf Outdoor ×1
1 project · most recent 03/07/2022
General Wiring
FiledStatusContractorScope
03/07/2022Permit IssuedROME ELECTRICAL CONTS INCGeneral Wiring
▾Special Inspection Requirements (DOB NOW) — 6
DateRequirementInspectorRole
09/06/2022HVAC-R and service water heating equipmentChris Siderisenergy_progress
09/06/2022Maintenance informationChris Siderisenergy_progress
09/06/2022HVAC-R and service water piping design and insulationChris Siderisenergy_progress
09/06/2022HVAC-R and service water heating system controlsChris Siderisenergy_progress
08/01/2022Mechanical SystemsChris Siderisspecial
08/01/2022FinalChris Siderisprogress
▾Documents — 28 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/25/2026Q00785106-I1Request digital key ↗
▸Applications & Permits6
▸BISPLAN / WORK APPROVAL APPLICATION4
01/25/2018421364892Open ↗
01/10/2018421364892Open ↗
12/27/2017421364892Open ↗
Showing 3 of 4 on file for this type
▸BISWORK PERMIT APPLICATION1
09/01/2016421364892Open ↗
▸BISNon-Directive 14 Construction Sign Off Including Sign Applications1
03/09/2018421364892Open ↗
▸Seals & Professional Certifications9
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION3
11/17/2017421364892Open ↗
09/01/2016421364892Open ↗
09/01/2016421364892Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/26/2026Q00785106-I1Open ↗
08/26/2026Q00785106-I1Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
09/01/2016421364892Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
09/01/2016421364892Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/25/2026Q00785106-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/26/2026Q00785106-I1Open ↗
▸Safety & Tenant Protection1
▸BISTenant Protection Plan and Notes1
09/01/2016421364892Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/25/2026Q00785106-I1Open ↗
▸Energy Compliance2
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS2
11/21/2017421364892Open ↗
09/01/2016421364892Open ↗
▸Approvals, Objections & Sign-offs2
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST2
03/09/2018421364892Open ↗
11/20/2017421364892Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
11/21/2017421364892Open ↗
09/01/2016421364892Open ↗
▸Filing & Intake Forms4
▸BISBOROUGH INTAKE FORM3
03/09/2018421364892Open ↗
01/09/2018421364892Open ↗
11/20/2017421364892Open ↗
▸BISEFILING COVER SHEET1
09/01/2016421364892Open ↗