← Back
Two stories - detached, small or mid-size
20 ACORN STREET
STATEN ISLAND · BIN 5058614
💬 Discuss this project
1930Year Built
2Stories
A1Building Class
R2Zoning
2,692 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
Two stories - detached, small or mid-size · 5,300 sf lot · 0.51 FAR built · Flood zone X
Locations of Work
PlumbingFire Protection
Floor 22p · 2 filings · 11 docs
Floor 1
2 jobs · most recent 06/05/2022
General Wiring
FiledStatusContractorScope
06/05/2022CompleteB & R ELEC'L CONTR'G, INCGeneral Wiring
12/27/2021CompleteB & R ELEC'L CONTR'G, INC1 meters, 1 new_meters
Building Lifecycle
All (22)Filed (5)Permit Issued (4)Signed Off (3)Violation (3)Inspection (7)
12/28/2022
Signed off — Alteration
Installation of new fire sprinkler system with valves and meters for same. Filed in conjunction with alteration type 1 application # 540191889.
S00372694-I1
12/23/2022
Signed off — Alteration
INSTALLATION OF NEW PLUMBING FIXTURES FOR A ONE-FAMILY DWELLING.
S00486364-I1
11/28/2022
Signed off — Alteration
INSTALLATION OF TEMPORARY 8' HIGH CONSTRUCTION FENCE.
S00431874-I1
10/11/2022
Filed — Alteration
INSTALLATION OF NEW PLUMBING FIXTURES FOR A ONE-FAMILY DWELLING.
S00486364-P2
10/11/2022
Inspection — Certified Sprinkler (PL)-Sprinkler-Hydro
Certified
View inspection ↗
10/11/2022
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
10/07/2022
Filed — Alteration
INSTALLATION OF NEW PLUMBING FIXTURES FOR A ONE-FAMILY DWELLING.
S00486364-P1
10/05/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
07/19/2022
Violation issued (ECB, closed)
Construction
06/09/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
06/03/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
04/22/2022
Violation issued (ECB, closed)
Construction
04/22/2022
Violation issued (ECB, closed)
Construction
03/08/2022
Inspection — Pass-Final PL - Underground
Pass
View inspection ↗
02/25/2022
Inspection — Pass-Final PL - Underground
Pass
View inspection ↗
02/16/2022
Permit issued — Plumbing
S00486364-I1-PL
02/16/2022
Permit issued — Plumbing
S00372694-I1-PL
02/01/2022
Permit issued — Construction Fence
S00431874-I1-FN
11/01/2021
Permit issued — Construction Fence
S00431874-I1-FN
10/26/2021
Filed — Alteration
INSTALLATION OF TEMPORARY 8' HIGH CONSTRUCTION FENCE.
S00431874-I1
04/01/2021
Filed — Alteration
Installation of new fire sprinkler system with valves and meters for same. Filed in conjunction with alteration type 1 application # 540191889.
S00372694-I1
03/19/2021
Filed — Alteration
INSTALLATION OF NEW PLUMBING FIXTURES FOR A ONE-FAMILY DWELLING.
S00486364-I1
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
PISILI303/22/2026
J RHOME CONSTRUCTION703/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
JOSEPH M. MORACE, A.I.A., ARCHITECT410/11/2022
A TECH ENGINEERING NYC, PLLC.104/01/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
VIP EXPEDITING303/21/2026
JOSEPH M. MORACE, ARCHITECT203/21/2026
A TECH ENGINEERING NYC203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
PISILI INCGeneral Contractor307/08/2026
FLOW-RIGHT PLBG & HTG CORPlumbing207/08/2026
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offFLOW-RIGHT PLBG & HTG COR02/16/2022
DOB NOWPlumbingSigned-offFLOW-RIGHT PLBG & HTG COR02/16/2022
DOB NOWConstruction FenceSigned-offPISILI INC02/01/2022
DOB NOWConstruction FenceSigned-offPISILI INC11/01/2021
BIS—ISSUEDPISILI INC07/25/2022
BIS—ISSUEDPISILI INC01/31/2022
BIS—ISSUEDPISILI INC11/03/2021
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
10/11/2022Certified Sprinkler (PL)-Sprinkler-HydroCertifiedView ↗
10/11/2022Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
10/05/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
06/09/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
06/03/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
03/08/2022Pass-Final PL - UndergroundPassView ↗
02/25/2022Pass-Final PL - UndergroundPassView ↗
▾Documents — 87 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch3
08/23/2026S00486364-I1Request digital key ↗
08/23/2026S00486364-P1Request digital key ↗
08/23/2026S00486364-P2Request digital key ↗
▸DOB NOWPlans/Sketch - Plumbing1
08/25/2026S00372694-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Construction Fence1
08/25/2026S00431874-I1Request digital key ↗
▸Applications & Permits5
▸BISPLAN / WORK APPROVAL APPLICATION2
12/03/2020540191889Open ↗
07/15/2020540177431Open ↗
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION1
10/04/2022540191889Open ↗
▸BISWORK PERMIT APPLICATION1
11/03/2021540191889Open ↗
▸BISBPP-5 - Authorization to the Department of Transportation1
07/15/2020540177431Open ↗
▸Zoning, Tax Lot & Property Records1
▸BISZONING EXHIBIT III:DESC. & OWNRSHP.STMNT1
12/03/2020540191889Open ↗
▸Seals & Professional Certifications10
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/23/2026S00486364-P1Open ↗
08/23/2026S00486364-I1Open ↗
08/13/2026S00431874-I1Open ↗
Showing 3 of 5 on file for this type
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY2
12/03/2020540191889Open ↗
07/15/2020540177431Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
12/03/2020540191889Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
12/03/2020540191889Open ↗
▸BISAPPLICANT OWNER SIGNATURE1
07/15/2020540177431Open ↗
▸Trade Schedules & Equipment7
▸BISDEP SANITARY SEWER CERTIFICATION (HCP/SCP)2
11/28/2022540191889Open ↗
12/03/2020540191889Open ↗
▸BISHVAC & SERVICE WATER HEATING EQUIPMENT1
11/28/2022540191889Open ↗
▸BISHVAC & SERVICE WATER HEATING SYSTEM CONTROLS1
11/28/2022540191889Open ↗
▸BISDEP STORMWATER SEWER CERTIFICATION (HCP/SCP)1
12/03/2020540191889Open ↗
▸BISDETECTOR:SMOKE-CERT. OF INSTALLATION1
12/08/2022540191889Open ↗
▸BISDETECTOR:CARBON MONOXIDE-CERT.OF INSTALL1
12/08/2022540191889Open ↗
▸Safety & Tenant Protection2
▸BISSTREET TREE CHECKLIST2
12/03/2020540191889Open ↗
07/15/2020540177431Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/23/2026S00486364-P1Open ↗
08/23/2026S00486364-I1Open ↗
08/13/2026S00486364-P2Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
12/03/2020540191889Open ↗
▸Energy Compliance11
▸BISFENESTRATION AIR LEAKAGE1
11/28/2022540191889Open ↗
▸BISAIR SEALING AND INSULATION - VISUAL1
12/08/2022540191889Open ↗
▸BISINTERIOR LIGHTING POWER1
11/28/2022540191889Open ↗
▸BISFENESTRATION U-FACTOR & PRODUCT RATING1
11/28/2022540191889Open ↗
▸BISFENESTRATION AREAS1
11/28/2022540191889Open ↗
▸BISAIR SEALING AND INSULATION - TESTING1
11/28/2022540191889Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
11/01/2021540191889Open ↗
▸BISINSULATION PLACEMENT & R VALUES1
11/28/2022540191889Open ↗
▸BISENERGY CODE COMPLIANCE INSPECTIONS1
11/28/2022540191889Open ↗
▸BISAS-BUILT ENERGY ANALYSIS (EN2)1
11/28/2022540191889Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
12/03/2020540191889Open ↗
▸Inspections & Test Reports17
▸BISTECHNICAL REPORT: RESPONSIBILITY5
01/03/2023540191889Open ↗
11/01/2021540191889Open ↗
11/01/2021540191889Open ↗
Showing 3 of 5 on file for this type
▸BISFRAME (2008)/STRUCTURAL WOOD FRAME (2014) INSPECTION1
11/28/2022540191889Open ↗
▸BISCONCRETE - CAST-IN-PLACE1
11/28/2022540191889Open ↗
▸BISSUBSURFACE / SOILS INVESTIGATION (BORINGS/TEST PITS)1
12/20/2022540191889Open ↗
▸BISSTRUCTURAL STABILITY - ALTERATIONS OF EXISTING BUILDINGS1
11/28/2022540191889Open ↗
▸BISFIRE-RESISTANT PENETRATIONS AND JOINTS (FIRESTOP)1
11/28/2022540191889Open ↗
▸BISFIRE-RESISTIVE RATED CONSTRUCTION1
11/28/2022540191889Open ↗
▸BISFOOTING AND FOUNDATION INSPECTION1
11/28/2022540191889Open ↗
▸BISSTRUCTURAL STEEL - HIGH STRENGTH BOLTING1
11/28/2022540191889Open ↗
▸BISBPP-9 - Request for Builders Pavement Field Inspection1
07/15/2020540177431Open ↗
▸BISSOIL REPORT1
12/03/2020540191889Open ↗
▸BISSUBGRADE INSP / SOILS-SITE PREP1
11/28/2022540191889Open ↗
▸BISSOIL PERC. TEST-STORM WATER SYSTEM (DRYWELL)1
11/28/2022540191889Open ↗
▸Cost, Insurance & Ownership3
▸BISCOST AFFIDAVIT1
12/03/2020540191889Open ↗
▸BISCOST AFFIDAVIT (FINAL): PW31
12/08/2022540191889Open ↗
▸BISHIC LICENSE OR AFFIDAVIT1
11/03/2021540191889Open ↗
▸Filing & Intake Forms3
▸BISEFILING JOB APPLICATION COVER SHEET2
12/03/2020540191889Open ↗
07/15/2020540177431Open ↗
▸BISADDITIONAL INFORMATION1
12/05/2022540191889Open ↗
▸Other Documents17
▸BISBPP - SUPPORTING DOCUMENTATION3
07/15/2020540177431Open ↗
07/15/2020540177431Open ↗
07/15/2020540177431Open ↗
▸BISON-SITE STORM WATER DRAIN. DISP. /DETENT INSTALL (DRYWELL)2
11/28/2022540191889Open ↗
11/28/2022540191889Open ↗
▸BISELECTRIC VEHICLE SERVICE EQUIPMENT REQUIREMENTS1
11/28/2022540191889Open ↗
▸BISSUSTAINABLE ROOF ZONE FORM1
02/04/2021540191889Open ↗
▸BISMAINTENANCE INFORMATION1
11/28/2022540191889Open ↗
▸BISHVAC & SERVICE WATER PIPING DESIGN AND INSULATION1
11/28/2022540191889Open ↗
▸BISPERMANENT CERTIFICATE1
11/28/2022540191889Open ↗
▸BISFIREPLACES1
11/28/2022540191889Open ↗
▸BISBPP: FILING REQUIRED1
12/03/2020540191889Open ↗
▸BISDUCT DESIGN, INSULATION AND LEAKAGE TESTING1
11/28/2022540191889Open ↗
▸BISCONSTRUCTION - SUPPORTING DOCUMENTATION1
11/02/2021540191889Open ↗
▸BISPROTECTION OF EXPOSED FOUNDATION INSULATION1
11/28/2022540191889Open ↗
▸BISVENTILATION AND AIR DISTRIBUTION SYSTEM1
11/28/2022540191889Open ↗
▸BISPLOT DIAGRAM1
12/03/2020540191889Open ↗