DOB09/18/2001V-DOB VIOLATION - ACTIVE
ECB08/10/2004FAILURE TO MAINTAIN EXTERIOR BLDG WALL.NOTED:ELECTRIC CABLE HANGS OVERPUBLIC SIDEWALK FROM SIGN PARTIALLY COLLAPSED SOFFITS AT REAR IN DANGER OF FURTHER COLLAPSE.MISSING AND DISPLACED ROOF SHINGLES AT NUMEROUSNothing owed — awaiting certificate of correction
ECB05/12/2003FAILURE TO MAINTAIN BUILDING-HAZARDOUS. NOTED: THE FACADE IS DETERIORATING AND THE HANGING METAL SIGN, APPROXIMATELY 3'X6' IS ALSO DETERIORATING. REMEDY: MAINTAIN BUILDING IMMEDIATELY.Nothing owed — awaiting certificate of correction
ECB04/22/2003FSAILURE TO MAINTAIN EXTERIOR BUILDING WALL. IN THAT AT REAR OF BUILDING MASONARY BLOCK WALL HAS COLLAPSED. ALSO REAR OF BUILDING IS IN DISREPAIR. REMEDY: MAINTAIN BUILDING AND MASONARY BLOCK WALL MAKE SAFE.Nothing owed — awaiting certificate of correction
ECB02/13/2003FAILURE TO MAINTIAN BLDG. NOTE: TOTAL COLLAPSE AT REAR OF BLDG MASONRY BLOCKS WALL IS LEANING APPROX 12 INCHES INTO PROPERTY OF ADJANING BLDG (91 MAPLE AVE) MASONRY WALL LEANNING INTO PROPERTY IS APPROX. 9 FT HNothing owed — awaiting certificate of correction
ECB02/27/2002FAILURE TO MAINTAIN NOTED: 1, SUBSTANTIAL INTERIOR FIRE DAMAGE PARTICULARLY AT TOP FLOOR. 2, ROOF PARPTERS CHARRED AND A 16'X20. HOLE BURNED THRU ROOF 3, ONE STORY EXTENSION AT REAR HAS COLLAPSED 4, BUILDING ISNothing owed — awaiting certificate of correction
ECB11/26/1999FAILURE TO MAINTAIN DEFECT IS: IN THAT WIMDOWS ARE BROKEN ON SECOND FLOOR AND GLASS IS FAILING ONTO THE SIDEWALK. ALSO OVERHEAD ROOF ON 2NF FLOOR SLATE TILES ARE IN DISREPAIR AND FALLING ONTO THE SIDEWALK BELOWNothing owed — awaiting certificate of correction
ECB11/08/1995WORK DONE WITHUT A PERMIT-WORK NOTED:HOT WATER HEATERS WERE INSTALLED IN KITCHENS AT SECOND AND THIRD FLOORS AND METAL FLUE PIPES ARE PARTIALLY DISCONNECTED AND WITHIN REACH OF CHILDREN AND ADULTS.REMEDY:MAKENothing owed — awaiting certificate of correction
ECB11/08/1995FAILURE TO MAINTAIN BLDG:NOTED:THE MASONRY BLOCK WALL LOCATED AT RIGHTSIDE(MIDDLE PORTION)OF FIRST FLOOR IS PARTIALLY BROKEN AND CRACKED.DAYLIGHT CAN BE SEEN FROM INTERIOR OF FIRST FLOOR.REMEDY:REPAIR AND/OR RENothing owed — awaiting certificate of correction
ECB11/08/1995FAILURE TO MAINTAIN IN THAT A MAJOR PORTION OF CONCRETE FLOOR LOCATED AT MIDDLE OF FIRST FLOOR IS BROKEN UP AND CONRETE IS MISSING EXPOSING WOOD SLEEPERS.REMEDY:REPAIR AND/OR REPLACE CONCRETE FLOOR.Nothing owed — awaiting certificate of correction
ECB11/08/1995FAILURE TO MIANTAIN:NOTED,THE CEILING OF WOOD STRUCTURE AND/OR CANOPY IS ROOTED,SAGGING AND IN DISREPAIR IN REAR YARD.REMEDY:REPAIR AND OR REPLACE WOOD STRUCTURE ADHERE TO DOB REGULATION IF REPLACEMENT IS NEEDNothing owed — awaiting certificate of correction
ECB11/08/1995FAILURE TO MAINTAIN IN THAT THE TWELVE COURSE MASONRY BLOCK RETAINING WALL LOCATED IN REAR YARD IS LEANING SOUTH AND IS OUT OF PLUMB APPROX.ONE FOOT.REMEDY:REPAIR AND/OR REPLACE RETAINING WALL.Nothing owed — awaiting certificate of correction
ECB11/08/1995FAILURE TO MAINTAIN IN THAT ELECTRICAL UTILITY ROOM LOCATED AT FIRST STORY IS FILLED WITH AN UNDERTERMINED AMOUNT OF WATER AND THE GAS METERS ARE LOCATED UNDER WATER IN SAME UTILITY ROOM.REMEDY:MAKE SAFE IMMEDNothing owed — awaiting certificate of correction
ECB06/22/1993OCCUPANCY CONTRARY TO THAT ALLOWED BY THE COFO#2455. THE OCCUPANCY ON THE SECOND FLOOR WAS CHANGED FROM DWELLING TO AN OFFICE. REMEDY:AMEND COFO OR DISCONTINUE ILLEGAL USE.Nothing owed — awaiting certificate of correction