Over six families without stores
200 COLUMBIA HEIGHTS
BROOKLYN · BIN 3001499
💬 Discuss this project
1844Year Built
4Stories
C1Building Class
R6Zoning
6,280 sfGross Floor Area
10Units
Rent Stabilized36 Open Violations 35 unresolved · 1 paperwork only ▸FDNY Report ↗
Over six families without stores · Owner of record: COLUMBIA HEIGHTS REALTY · 2,492 sf lot · 2.52 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalGeneral
Roof1p · 1 filing · 10 docs
Floor 11p · 1 filing · 5 docs
Cellar3p · 2 filings · 20 docs
Basement2p · 1 filing · 10 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
COLUMBIA HEIGHTS REALTY5707/08/2026
RENNON CONSTRUCTION503/22/2026
MALBRO303/22/2026
MALBORO INC103/22/2026
200 COLUMBIA HEIGHTS REALTY1203/21/2026
BEACH CHANNEL DRIVE REALTY203/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
WALTER T. GORMAN, P.E., P.C.607/30/2024
ASHRAF CORP107/09/2021
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MALBRO CONST SERVICES INCGeneral Contractor1107/08/2026
RENNON CONSTRUCTION CORPGeneral Contractor203/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
WALTER T. GORMAN, P.E., P268308/01/2023
Building Lifecycle
All (115)Filed (7)Permit Issued (6)Signed Off (3)Violation (60)Objection (28)Special Inspection (11)
05/04/2026
Violation issued (HPD, open)
A
06/09/2025
Violation issued (HPD, closed)
A
02/04/2025
Objection resolved — Addressed
02/04/2025
Objection resolved — Addressed
02/04/2025
Objection resolved — Addressed
02/04/2025
Objection resolved — Addressed
02/04/2025
Objection resolved — Addressed
02/04/2025
Objection resolved — Addressed
02/04/2025
Objection resolved — Addressed
11/25/2024
Violation issued (HPD, closed)
I
08/05/2024
Objection raised — Scope
08/05/2024
Objection raised — Scope
08/05/2024
Objection raised — Fire_Protection
08/05/2024
Objection raised — Scope
08/05/2024
Objection raised — Scope
08/05/2024
Objection raised — Scope
08/05/2024
Objection raised — Fire_Protection
08/05/2024
Objection raised — Admin
08/05/2024
Objection raised — Zoning
07/30/2024
Filed — Alteration
INSTALLATION OF NEW SPLIT AIR COOLED AC SYSTEM FOR COOLING AND HEATING ON ALL FLOORS. INSTALLATION OF CONDENSING UNITS ON THE ROOF. EXISTING RADIATORS AND ASSOCIATED PIPING AND EQUIPMENT TO BE REMOVED. ASSOCIATED CONSTRUCTION WORK AND REMEDIAL WORK.
B01058547-I1
06/18/2024
Special inspection requirement — Heating Systems
06/18/2024
Special inspection requirement — Tenant Protection Plan Compliance
05/29/2024
Special inspection requirement — Mechanical Systems
05/29/2024
Special inspection requirement — Final
05/13/2024
Signed off — Alteration
INSTALL NEW INTERIOR STAIR (CONVENIENCE STAIR) AT CELLAR TO BASEMENT & INTERIOR ALTERATIONS.
B00595168-I1
05/13/2024
Signed off — Alteration
Repair existing exterior facade to restore to original condition. Replace existing ladder to new stair at cellar. Replace windows and door at cellar. Repair/replace wood deck at 3rd floor.
B00605351-I1
04/09/2024
Violation issued (HPD, closed)
A
03/27/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
02/07/2024
Signed off — Alteration
B00549585-I1
11/17/2023
Violation issued (HPD, closed)
I
10/25/2023
Special inspection requirement — Final
Walter Gorman
09/15/2023
Objection resolved — Addressed
08/03/2023
Objection raised — Admin
08/03/2023
Objection resolved — Addressed
08/02/2023
Objection raised — Scope
08/01/2023
Filed — Alteration
Repair existing exterior facade to restore to original condition. Replace existing ladder to new stair at cellar. Replace windows and door at cellar. Repair/replace wood deck at 3rd floor.
B00605351-P1
08/01/2023
Filed — Alteration
INSTALL NEW INTERIOR STAIR (CONVENIENCE STAIR) AT CELLAR TO BASEMENT & INTERIOR ALTERATIONS.
B00595168-P1
07/28/2023
Special inspection requirement — Final
Walter Gorman
07/28/2023
Special inspection requirement — Fire-Resistance Rated Construction
Walter Gorman
07/28/2023
Special inspection requirement — Final
Walter Gorman
07/28/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Walter Gorman
07/07/2023
Permit issued — General Construction
B00876074-I1-GC
06/02/2023
Objection resolved — Addressed
06/01/2023
Objection raised — Other
05/25/2023
Filed — Alteration
REPAIR EXTERIOR BRICK COLUMNS AT ENTRANCE STAIRTO ADDRESS ECB NOV# 35646977Y AS PER PLANS. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
B00876074-I1
05/23/2023
Special inspection requirement — Tenant Protection Plan Compliance
Walter Gorman
05/16/2023
Special inspection requirement — Final
Walter Gorman
03/22/2023
Violation issued (HPD, closed)
A
03/10/2023
Violation issued (ECB, open)
Construction
12/09/2022
Permit issued — General Construction
B00605351-I1-GC
11/04/2022
Violation issued (HPD, closed)
I
05/05/2022
Violation issued (ECB, closed)
Boilers
04/26/2022
Permit issued — General Construction
B00595168-I1-GC
02/23/2022
Violation issued (HPD, closed)
I
02/23/2022
Violation issued (HPD, closed)
A
11/22/2021
Permit issued — General Construction
B00605351-I1-GC
11/02/2021
Filed — Alteration
Repair existing exterior facade to restore to original condition. Replace existing ladder to new stair at cellar. Replace windows and door at cellar. Repair/replace wood deck at 3rd floor.
B00605351-I1
10/22/2021
Permit issued — General Construction
B00595168-I1-GC
10/21/2021
Objection raised — Other
10/21/2021
Objection resolved — Addressed
Latest 60 of 115 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedMALBRO CONST SERVICES INC07/07/2023
DOB NOWGeneral ConstructionSigned-offMALBRO CONST SERVICES INC12/09/2022
DOB NOWGeneral ConstructionSigned-offMALBRO CONST SERVICES INC04/26/2022
DOB NOWGeneral ConstructionSigned-offMALBRO CONST SERVICES INC11/22/2021
DOB NOWGeneral ConstructionSigned-offMALBRO CONST SERVICES INC10/22/2021
DOB NOWSupported ScaffoldSigned-offRENNON CONSTRUCTION CORP07/12/2021
BISOTISSUEDMALBRO CONST SERVICES INC11/12/2019
BISPLISSUEDMCMANUS MECH MAINT P&H INC02/27/2014
BISPLISSUEDW.G. PLBG & HTG CORP02/03/2014
BISOTISSUEDMALBRO CONST SERVICES INC11/18/2013
BISOTISSUEDNORTH AMERICAN CONTRACTIN02/12/2013
BISPLISSUEDW.G. PLBG & HTG CORP02/12/2013
BISEQISSUEDMALBRO INC02/06/2013
BISEQISSUEDMALBRO INC01/29/2013
BISPLISSUEDMCMANUS MECH MAINT P&H INC10/17/2012
BISOTISSUEDNORTH AMERICAN CONTRACTIN10/17/2012
BISOTISSUEDNORTH AMERICAN CONTRACTIN08/22/2012
BISOTISSUEDNORTH AMERICAN CONTRACTIN07/25/2012
BISOTISSUEDNORTH AMERICAN CON. SVCS10/28/2011
BISOTISSUEDNORTH AMERICAN CON. SVCS10/28/2011
BISOTISSUEDNORTH AMERICAN CON. SVCS10/28/2011
BISOTISSUEDNORTH AMERICAN CON. SVCS10/28/2011
BISEQISSUEDMALBRO INC10/19/2011
BISEQISSUEDMALBRO INC10/13/2011
BISOTISSUEDNORTH AMERICAN CON. SVCS03/23/2011
BISOTISSUEDNORTH AMERICAN CON. SVCS03/23/2011
BISOTISSUEDNORTH AMERICAN CON. SVCS03/16/2011
BISOTISSUEDNORTH AMERICAN CON. SVCS03/16/2011
BISPLISSUEDMCMANUS MECH MAINT P&H INC03/10/2011
BISPLISSUEDMCMANUS MECH MAINT P&H INC03/10/2011
BISPLISSUEDINTERNATIONAL PLUMBING & HEATING04/11/2008
BISPLISSUEDINTERNATIONAL PLUMBING & HEATING12/10/2007
BISPLISSUEDJ M S PLUMBING & HEATING08/17/2005
BISOTISSUEDCOLUMBNIA HEIGHTS REALTY LLC08/05/2005
BISPLISSUEDMOST PLBG & HTG CORP05/04/2004
BISOTISSUEDWALTER T GORMAN PE PC03/15/2004
BISPLISSUEDMOST PLBG & HTG CORP11/28/2003
BISOTISSUEDV.H.I CONSTRUCTION CORP08/19/2003
BISOTISSUEDV.H.I CONSTRUCTION CORP01/23/2003
BISPLISSUEDMOST PLBG & HTG CORP11/29/2002
1 project · most recent 07/30/2024
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
07/30/2024——Heating and Air Conditioning Systems
Heat / Cool
Mitsubishi Electric Indoor Unit: MSZ-GL06NA 6,000 BTU · Heat Pump Outdoor ×7
Indoor Unit: SEZ-KD12NA; Outdoor Unit: SUZ-KA 12NA 12,000 BTU · Heat Pump Outdoor ×5
Outdoor Unit: MXZ-8C48NAHZ 48,000 BTU · Heat Pump Outdoor ×3
indoor Unit: PEAD-24AA7; Outdoor Unit: PUZ-A24NHA7 24,000 BTU · Heat Pump Outdoor ×3
Indoor Unit: PEAD-A36AA7; Outdoor Unit: PUZ-A36NKA7-BS 36,000 BTU · Heat Pump Outdoor ×2
Outdoor Unit: MXZ-3C30NA2 30,000 BTU · Heat Pump Outdoor ×2
SEZ-KD18NA; Outdoor Unit: SUZ-KA 18NA; Remote Controller: PAR-21MAA 17,000 BTU · Heat Pump Outdoor ×2
Indoor Unit: PKA-A30KA7; Outdoor Unit: PUY-A30NHA7-BS 30,000 BTU · Heat Pump Outdoor ×1
Indoor Unit: PKA-A30NHA7; Outdoor Unit: PUY-A30NHA7-BS 30,000 BTU · Heat Pump Outdoor ×1
Indoor Unit: PUZ-A36NKA7; Outdoor Unit: PUZ-A36NKA7-BS 36,000 BTU · Heat Pump Outdoor ×1
MSZ-GL24NA 22,000 BTU · Heat Pump Outdoor ×1
Outdoor Unit: MXZ-4C36NA2 36,000 BTU · Heat Pump Outdoor ×1
1 project · most recent 12/08/2020
General Wiring
FiledStatusContractorScope
12/08/2020Permit IssuedWTG ELECTRIC INC.General Wiring
▾Special Inspection Requirements (DOB NOW) — 11
DateRequirementInspectorRole
06/18/2024Heating Systems—special
06/18/2024Tenant Protection Plan Compliance—special
05/29/2024Mechanical Systems—special
05/29/2024Final—progress
10/25/2023FinalWalter Gormanprogress
07/28/2023FinalWalter Gormanprogress
07/28/2023Fire-Resistance Rated ConstructionWalter Gormanprogress
07/28/2023FinalWalter Gormanprogress
07/28/2023Fire-Resistant Penetrations and JointsWalter Gormanspecial
05/23/2023Tenant Protection Plan ComplianceWalter Gormanspecial
05/16/2023FinalWalter Gormanprogress
▾Documents — 136 on file (BIS + DOB NOW)
▸Plans & Drawings7
▸DOB NOWPlans/Sketch7
09/01/2026B00549585-I1Request digital key ↗
08/31/2026B00605351-I1Request digital key ↗
08/15/2026B00595168-P1Request digital key ↗
Showing 3 of 7 on file for this type
▸Applications & Permits37
▸BISWORK PERMIT APPLICATION21
10/12/2019321993633Open ↗
03/03/2014340099440Open ↗
02/03/2014340099440Open ↗
Showing 3 of 21 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION10
08/22/2022301439851Open ↗
08/17/2022340099440Open ↗
10/09/2019321993633Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWLPC Approval/Permit5
08/13/2026B00876074-I1Open ↗
08/13/2026B00595168-P1Open ↗
08/13/2026B00595168-I1Open ↗
Showing 3 of 5 on file for this type
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION1
10/09/2019321993633Open ↗
▸Seals & Professional Certifications35
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION9
10/09/2019321993633Open ↗
12/07/2015340023352Open ↗
11/24/2015340023352Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature7
09/01/2026B00549585-I1Open ↗
09/01/2026B00595168-P1Open ↗
09/01/2026B00595168-I1Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWProgress Inspector Seal & Signature4
09/21/2026B00595168-P1Open ↗
09/20/2026B00605351-I1Open ↗
08/25/2026B00876074-I1Open ↗
Showing 3 of 4 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM3
10/14/2011320378015Open ↗
10/14/2011320378024Open ↗
12/10/2007310059209Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST3
10/14/2011320378015Open ↗
10/14/2011320378024Open ↗
12/10/2007310059209Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION2
11/18/2013340099440Open ↗
11/28/2012340023352Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT2
11/18/2013340099440Open ↗
11/28/2012340023352Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY2
11/18/2013340099440Open ↗
11/28/2012340023352Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
09/21/2026B00595168-P1Open ↗
08/25/2026B00876074-I1Open ↗
▸BISPC FULL REPORT1
12/10/2007310059209Open ↗
▸Trade Schedules & Equipment9
▸BISSELF-CERT PLUMBING NOTICE6
06/28/2013340023352Open ↗
06/27/2013340023352Open ↗
05/16/2013340023352Open ↗
Showing 3 of 6 on file for this type
▸BISSCHEDULE B - PLUMBING3
02/10/2016340099440Open ↗
11/18/2013340099440Open ↗
11/28/2012340023352Open ↗
▸Safety & Tenant Protection1
▸BISTenant Protection Plan and Notes1
10/09/2019321993633Open ↗
▸Environmental & Asbestos10
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/31/2026B00605351-I1Open ↗
08/15/2026B00595168-P1Open ↗
08/15/2026B00595168-I1Open ↗
Showing 3 of 5 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)2
10/09/2019321993633Open ↗
11/18/2013340099440Open ↗
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'2
12/31/2009320108511Open ↗
12/10/2007310059209Open ↗
▸BISACP5 ASBESTOS: CERTIFICATION (DEP ACP5)1
02/12/2013340023352Open ↗
▸Energy Compliance1
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
10/09/2019321993633Open ↗
▸Inspections & Test Reports2
▸BISTECHNICAL REPORT: RESPONSIBILITY2
11/18/2013340099440Open ↗
11/28/2012340023352Open ↗
▸Approvals, Objections & Sign-offs16
▸BISLANDMARKS APPROVAL5
10/09/2019321993633Open ↗
11/18/2013340099440Open ↗
05/02/2013310059209Open ↗
Showing 3 of 5 on file for this type
▸BISADMINISTRATIVE OBJECTIONS4
10/14/2011320378024Open ↗
10/14/2011320378015Open ↗
12/31/2009320108511Open ↗
Showing 3 of 4 on file for this type
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST4
12/07/2015340023352Open ↗
11/24/2015340023352Open ↗
04/17/2013310059209Open ↗
Showing 3 of 4 on file for this type
▸BISLETTERS - SUPPORTING DOCUMENTATION3
03/03/2014340099440Open ↗
03/17/2011310059209Open ↗
03/14/2011310059209Open ↗
▸Cost, Insurance & Ownership9
▸BISCOST AFFIDAVIT9
10/09/2019321993633Open ↗
02/10/2016340099440Open ↗
12/29/2014340023352Open ↗
Showing 3 of 9 on file for this type
▸Filing & Intake Forms9
▸BISEFILING COVER SHEET4
10/09/2019321993633Open ↗
10/14/2011320378024Open ↗
10/14/2011320378015Open ↗
Showing 3 of 4 on file for this type
▸BISADDITIONAL INFORMATION3
11/23/2015340099440Open ↗
10/14/2011320378024Open ↗
10/14/2011320378015Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET2
11/18/2013340099440Open ↗
11/28/2012340023352Open ↗