← Back
Two family converted from one family
200 WASHINGTON PARK
BROOKLYN · BIN 3058420
💬 Discuss this project
1865Year Built
3Stories
B3Building Class
R6BZoning
4,400 sfGross Floor Area
2Units
Rent Stabilized22 Open Violations ▸FDNY Report ↗
Two family converted from one family · 2,200 sf lot · 2 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire Protection
Roof6p · 4 filings · 20 docs
Floor 38p · 3 filings · 20 docs
Floor 216p · 5 filings · 20 docs
Floor 16p · 2 filings · 20 docs
Cellar15p · 5 filings · 20 docs
Basement7p · 3 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
BTR INNOVATIVE BUILDERS407/08/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
04/27/2021$4.1M—— → —$933/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NEUHAUS DESIGN ARCHITECTURE, P.C.503/20/2024
D'ANTONIO CONSULTING ENGINEERS803/21/2023
D'HUY ENGINEERING, INC.503/17/2023
ASHRAF CORP103/11/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
J CALLAHAN CONSULTING3603/21/2026
Rigid Structural Design, LLC103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
A.E. GREYSON & CO, INCGeneral Contractor1707/08/2026
PHOENIX PLMBG MECHPlumbing503/22/2026
SIMPLE CHOICE PLBG AND HTPlumbing507/08/2026
WCK ELECTRIC CORP.Electrical103/22/2026
PHOENIX PLMBG & MECH CORPFire Protection107/08/2026
KIMBERLY NEUHAUSElectrical103/21/2026
BTR INNOVATIVE BUILDERS IGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
D'ANTONIO CONSULTING ENGI9311303/20/2024
D'HUY ENGINEERING, INC.33381003/20/2024
MACIA INSPECTION & TESTIN402603/17/2023
Building Lifecycle
All (143)Filed (19)Permit Issued (17)Signed Off (6)Violation (39)Inspection (6)Objection (26)Special Inspection (30)
05/06/2026
Violation issued (HPD, open)
A
11/18/2025
Violation issued (HPD, open)
I
11/14/2025
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/11/2025
Violation issued (HPD, open)
A
11/25/2024
Violation issued (HPD, open)
I
09/23/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
04/12/2024
Violation issued (HPD, open)
A
04/01/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
GAETANO D'ANTONIO
04/01/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
PETER GARLAND
04/01/2024
Special inspection requirement — Fire-Resistance Rated Construction
Kimberly Neuhaus
03/20/2024
Filed — Alteration CO
Convert existing two family row house to single family residence. Revise configuration from upper triplex with a basement level rental unit to single family residence. Installation new steel deck and stair at rear yard. Enlarge rear masonry openings.
B00556381-P4
03/01/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
GAETANO D'ANTONIO
03/01/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
PETER GARLAND
03/01/2024
Special inspection requirement — Fire-Resistance Rated Construction
Kimberly Neuhaus
01/31/2024
Objection resolved — Addressed
01/25/2024
Objection raised — Other
01/19/2024
Filed — Alteration CO
Convert existing two family row house to single family residence. Revise configuration from upper triplex with a basement level rental unit to single family residence. Installation new steel deck and stair at rear yard. Enlarge rear masonry openings.
B00556381-P3
12/20/2023
Special inspection requirement — Structural Stability – Alterations of existing buildings
PETER GARLAND
12/20/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
GAETANO D'ANTONIO
12/20/2023
Special inspection requirement — Fire-Resistance Rated Construction
Kimberly Neuhaus
11/17/2023
Violation issued (HPD, open)
I
06/30/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/20/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/20/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/20/2023
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
06/08/2023
Objection resolved — Addressed
06/07/2023
Objection raised — Other
06/05/2023
Filed — Alteration CO
Convert existing two family row house to single family residence. Revise configuration from upper triplex with a basement level rental unit to single family residence. Installation new steel deck and stair at rear yard. Enlarge rear masonry openings.
B00556381-P2
05/23/2023
Special inspection requirement — Structural Stability – Alterations of existing buildings
PETER GARLAND
05/23/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
GAETANO D'ANTONIO
05/23/2023
Special inspection requirement — Fire-Resistance Rated Construction
Kimberly Neuhaus
05/20/2023
Signed off — Alteration
FOUNDATION WORK AS PER PLANS. NO CHANGE OF USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B00631953-I1
05/20/2023
Signed off — Alteration
STRUCTURAL WORK AS PER PLANS. NO CHANGE OF USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B00588145-I1
05/18/2023
Signed off — Alteration
PLUMBING WORK AS PER PLANS. NO CHANGE OF USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B00556373-I1
04/25/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
04/04/2023
Signed off — Alteration
MECHANICAL WORK AS PER PLANS. NO CHANGE OF USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B00556375-I1
04/04/2023
Special inspection requirement — Heating Systems
GAETANO D'ANTONIO
04/04/2023
Special inspection requirement — Final
GAETANO D'ANTONIO
04/04/2023
Special inspection requirement — Mechanical Systems
GAETANO D'ANTONIO
04/01/2023
Objection resolved — Addressed
04/01/2023
Objection resolved — Addressed
03/27/2023
Violation issued (HPD, open)
A
03/24/2023
Objection raised — Structural
03/24/2023
Objection raised — Admin
03/24/2023
Objection resolved — Addressed
03/24/2023
Special inspection requirement — Post-installed Anchors
RONALD CARR
03/24/2023
Special inspection requirement — Structural Stability – Alterations of existing buildings
RONALD CARR
03/24/2023
Special inspection requirement — Masonry
RONALD CARR
03/24/2023
Special inspection requirement — Subsurface Conditions – Fill Placement & In-Place Density
Jeffrey Stones
03/24/2023
Special inspection requirement — Subgrade Inspections
Jeffrey Stones
03/24/2023
Special inspection requirement — Concrete - Cast-In-Place
RONALD CARR
03/24/2023
Special inspection requirement — Footing and Foundation
RONALD CARR
03/24/2023
Special inspection requirement — Final
RONALD CARR
03/23/2023
Objection resolved — Addressed
03/23/2023
Objection resolved — Addressed
03/23/2023
Objection resolved — Addressed
03/22/2023
Objection resolved — Addressed
03/22/2023
Objection resolved — Addressed
03/21/2023
Filed — Alteration
MECHANICAL WORK AS PER PLANS. NO CHANGE OF USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B00556375-P2
03/20/2023
Objection raised — Energy
Latest 60 of 143 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offA.E. GREYSON & CO, INC01/23/2023
DOB NOWStructuralSigned-offA.E. GREYSON & CO, INC01/23/2023
DOB NOWGeneral ConstructionPermit IssuedA.E. GREYSON & CO, INC01/23/2023
DOB NOWFoundationSigned-offA.E. GREYSON & CO, INC01/23/2023
DOB NOWGeneral ConstructionPermit IssuedA.E. GREYSON & CO, INC12/28/2022
DOB NOWMechanical SystemsSigned-offA.E. GREYSON & CO, INC12/28/2022
DOB NOWPlumbingSigned-offSIMPLE CHOICE PLBG AND HT12/15/2022
DOB NOWPlumbingSigned-offSIMPLE CHOICE PLBG AND HT03/16/2022
DOB NOWSupported ScaffoldSigned-offBTR INNOVATIVE BUILDERS I03/15/2022
DOB NOWSprinklersSigned-offGW MECHANICAL CORP01/27/2022
DOB NOWStructuralSigned-offA.E. GREYSON & CO, INC01/17/2022
DOB NOWFoundationSigned-offA.E. GREYSON & CO, INC01/17/2022
DOB NOWGeneral ConstructionPermit IssuedA.E. GREYSON & CO, INC12/27/2021
DOB NOWMechanical SystemsSigned-offA.E. GREYSON & CO, INC12/22/2021
DOB NOWPlumbingSigned-offSIMPLE CHOICE PLBG AND HT11/22/2021
DOB NOWMechanical SystemsSigned-offA.E. GREYSON & CO, INC11/19/2021
DOB NOWGeneral ConstructionPermit IssuedA.E. GREYSON & CO, INC11/19/2021
BISPLISSUEDKCM PLUMBING & HEATING CO04/03/2017
BISSPISSUEDWALTER J. GRANDE P&H INC.01/27/2016
BISPLISSUEDKCM PLUMBING & HEATING CO01/06/2016
BISPLISSUEDKCM PLUMBING & HEATING CO12/17/2014
BISPLISSUEDW.G. PLBG & HTG CORP01/23/2013
BISPLISSUEDW.G. PLBG & HTG CORP01/11/2013
BISSPISSUEDE.H.FIRE SUPPRESSION CO01/08/2013
BISPLISSUEDENTERPRISE PLBG & HTG INC12/12/2012
BIS—ISSUEDDESANTIS CONSTRUCTION COR09/10/2012
BISPLISSUEDDEWATERS PLUMBING & HEATING, LLC03/19/2007
BISOTISSUEDNEW YORK RENOV INC01/05/2007
4 projects · most recent 03/11/2022
General Wiring
FiledStatusContractorScope
03/11/2022CompleteV.I.P. ELECTL CONTNG CORP—
11/15/2021CompleteV.I.P. ELECTL CONTNG CORPGeneral Wiring
12/14/2020CompleteWCK ELECTRIC CORP.1 meters, 1 new_meters
06/26/2018CompleteWCK ELECTRIC CORP.3 meters, 2 new_meters
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
06/20/2023Pass-Final CND-Occupancy InspectionPassView ↗
02/17/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
02/03/2023Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
07/15/2022Certified Gas-Gas-Piping-RoughingCertifiedView ↗
06/21/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
04/27/2022Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 51
DateRequirementInspectorRole
04/01/2024Fire-Resistant Penetrations and JointsGAETANO D'ANTONIOspecial
04/01/2024Structural Stability – Alterations of existing buildingsPETER GARLANDspecial
04/01/2024Fire-Resistance Rated ConstructionKimberly Neuhausprogress
03/01/2024Fire-Resistant Penetrations and JointsGAETANO D'ANTONIOspecial
03/01/2024Structural Stability – Alterations of existing buildingsPETER GARLANDspecial
03/01/2024Fire-Resistance Rated ConstructionKimberly Neuhausprogress
12/20/2023Structural Stability – Alterations of existing buildingsPETER GARLANDspecial
12/20/2023Fire-Resistant Penetrations and JointsGAETANO D'ANTONIOspecial
12/20/2023Fire-Resistance Rated ConstructionKimberly Neuhausprogress
05/23/2023Structural Stability – Alterations of existing buildingsPETER GARLANDspecial
05/23/2023Fire-Resistant Penetrations and JointsGAETANO D'ANTONIOspecial
05/23/2023Fire-Resistance Rated ConstructionKimberly Neuhausprogress
04/04/2023Heating SystemsGAETANO D'ANTONIOspecial
04/04/2023FinalGAETANO D'ANTONIOprogress
04/04/2023Mechanical SystemsGAETANO D'ANTONIOspecial
03/24/2023Post-installed AnchorsRONALD CARRspecial
03/24/2023Structural Stability – Alterations of existing buildingsRONALD CARRspecial
03/24/2023MasonryRONALD CARRspecial
03/24/2023Subsurface Conditions – Fill Placement & In-Place DensityJeffrey Stonesspecial
03/24/2023Subgrade InspectionsJeffrey Stonesspecial
03/24/2023Concrete - Cast-In-PlaceRONALD CARRspecial
03/24/2023Footing and FoundationRONALD CARRprogress
03/24/2023FinalRONALD CARRprogress
03/13/2023MasonryRONALD CARRspecial
03/13/2023Concrete - Cast-In-PlaceRONALD CARRspecial
Latest 25 of 51.
▾Documents — 210 on file (BIS + DOB NOW)
▸Plans & Drawings19
▸DOB NOWPlans/Sketch19
09/01/2026B00556373-P1Request digital key ↗
09/01/2026B00556373-I1Request digital key ↗
09/01/2026B00556373-P2Request digital key ↗
Showing 3 of 19 on file for this type
▸Applications & Permits31
▸DOB NOWLPC Approval/Permit13
08/13/2026B00556381-P4Open ↗
08/13/2026B00631953-P1Open ↗
08/13/2026B00556381-I1Open ↗
Showing 3 of 13 on file for this type
▸BISWORK PERMIT APPLICATION8
04/19/2017320419043Open ↗
01/28/2016320518043Open ↗
12/23/2014320518043Open ↗
Showing 3 of 8 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION7
01/27/2021320419043Open ↗
01/27/2021320419043Open ↗
03/09/2017320419043Open ↗
Showing 3 of 7 on file for this type
▸BISPLAN - WORK & PERMITS - SUPPPORTING DOCUMENTATION2
08/03/2018320419043Open ↗
04/13/2018320419043Open ↗
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION1
08/15/2013320419043Open ↗
▸Zoning, Tax Lot & Property Records2
▸BISCO OBJ: VERIFY ADDRESS-TOPO STAMP1
02/22/2021320419043Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026B00556381-I1Open ↗
▸Seals & Professional Certifications76
▸DOB NOWSpecial Inspector Seal & Signature36
09/27/2026B00556381-P3Open ↗
09/27/2026B00556375-I1Open ↗
09/27/2026B00556375-I1Open ↗
Showing 3 of 36 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature19
09/01/2026B00556373-P1Open ↗
09/01/2026B00556373-I1Open ↗
09/01/2026B00556373-P2Open ↗
Showing 3 of 19 on file for this type
▸DOB NOWProgress Inspector Seal & Signature14
09/27/2026B00556375-I1Open ↗
09/27/2026B00556381-P3Open ↗
09/25/2026B00556381-P4Open ↗
Showing 3 of 14 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION5
01/08/2018320419043Open ↗
01/08/2018320419043Open ↗
09/29/2017320518043Open ↗
Showing 3 of 5 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
07/26/2012320518043Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
07/26/2012320518043Open ↗
▸Trade Schedules & Equipment11
▸BISSCHEDULE B - PLUMBING3
09/29/2014320419043Open ↗
07/26/2012320518043Open ↗
01/07/2012320419043Open ↗
▸BISDETECTOR:SMOKE-CERT. OF INSTALLATION2
01/19/2018320419043Open ↗
01/19/2018320419043Open ↗
▸BISSELF-CERT PLUMBING NOTICE2
02/26/2013320518043Open ↗
02/15/2013320419043Open ↗
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE1
05/19/2015320419043Open ↗
▸BISEQUIPMENT USE APPLICATION/PERMIT1
02/02/2021320419043Open ↗
▸BISDETECTOR:CARBON MONOXIDE-CERT.OF INSTALL1
12/30/2020320419043Open ↗
▸BISEQUIPMENT USE PERMITS1
02/02/2021320419043Open ↗
▸Safety & Tenant Protection28
▸DOB NOWHPD-3: Single Room Occupancy Multiple Dwelling (SRO MD) Anti-Harassment Checklist19
09/01/2026B00556373-P2Open ↗
08/13/2026B00556373-I1Open ↗
08/13/2026B00556381-I1Open ↗
Showing 3 of 19 on file for this type
▸DOB NOWStreet Tree Checklist5
08/25/2026B00556381-P1Open ↗
08/25/2026B00556381-I1Open ↗
08/25/2026B00556381-P4Open ↗
Showing 3 of 5 on file for this type
▸BISSRO MD ANTI-HARASSMENT CHECKLIST1
01/07/2012320419043Open ↗
▸BISSTREET TREE CHECKLIST1
01/07/2012320419043Open ↗
▸BISSTREET TREE SIGNOFF1
12/30/2020320419043Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026B00556381-I1Open ↗
▸Environmental & Asbestos8
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form6
09/01/2026B00556373-I1Open ↗
09/01/2026B00556375-I1Open ↗
09/01/2026B00556378-I1Open ↗
Showing 3 of 6 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
07/26/2012320518043Open ↗
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
01/07/2012320419043Open ↗
▸Energy Compliance4
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS2
01/08/2018320419043Open ↗
01/08/2018320419043Open ↗
▸BISAS-BUILT ENERGY ANALYSIS (EN2)1
12/30/2020320419043Open ↗
▸BISTR8: Energy Code Progress Inspections1
08/21/2012320419043Open ↗
▸Inspections & Test Reports1
▸BISHYDRO FLOW TEST LETTER1
07/26/2012320518043Open ↗
▸Approvals, Objections & Sign-offs13
▸BISSCHEDULE A - OCCUPANCY / USE4
01/27/2021320419043Open ↗
05/19/2015320419043Open ↗
03/16/2012320419043Open ↗
Showing 3 of 4 on file for this type
▸BISLETTERS - SUPPORTING DOCUMENTATION2
01/24/2013320419043Open ↗
07/26/2012320518043Open ↗
▸BISLANDMARKS APPROVAL2
09/11/2012320518043Open ↗
08/13/2012320419043Open ↗
▸BISADMINISTRATIVE OBJECTIONS2
07/26/2012320518043Open ↗
01/07/2012320419043Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
09/29/2017320518043Open ↗
▸BISLANDMARKS SIGNOFF1
02/22/2021320419043Open ↗
▸BISSUPERSEDING LETTER1
04/19/2017320419043Open ↗
▸Cost, Insurance & Ownership4
▸BISCOST AFFIDAVIT3
09/29/2017320518043Open ↗
07/26/2012320518043Open ↗
01/07/2012320419043Open ↗
▸BISCOST AFFIDAVIT ESTIMATE: (PW3)1
12/30/2020320419043Open ↗
▸Filing & Intake Forms9
▸BISADDITIONAL INFORMATION6
08/14/2018320419043Open ↗
06/13/2016320518043Open ↗
08/12/2015320419043Open ↗
Showing 3 of 6 on file for this type
▸BISEFILING COVER SHEET2
07/26/2012320518043Open ↗
01/07/2012320419043Open ↗
▸BISBOROUGH INTAKE FORM1
09/29/2017320518043Open ↗
▸Other Documents4
▸DOB NOWProof of Historic Building2
08/13/2026B00631953-P1Open ↗
08/13/2026B00631953-I1Open ↗
▸BISPLOT DIAGRAM1
01/07/2012320419043Open ↗
▸DOB NOWFinal Survey1
08/13/2026B00556381-I1Open ↗