← Back
Predominantly retail with other uses
2004 3 AVENUE
MANHATTAN · East Harlem (South) · BIN 1082324
💬 Discuss this project
1900Year Built
4Stories
K4Building Class
R9Zoning
23,144 sfGross Floor Area
31Units
Rent Stabilized134 Open Violations ▸
Predominantly retail with other uses · Owner of record: D Y C CORP. · 7,569 sf lot · 3.06 FAR built · Flood zone X500
Locations of Work
MechanicalPlumbing
Permit Issued — active, not yet Signed-off
RoofUnder Construction1 filing · 8 docs
Floor 1Under Construction2 filings · 13 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
DYC CORP103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
JOSE A. SANTOS P.E.P.C103/09/2020
LEDER-LUIS ARCHITECTURAL DESIGN, PL201/23/2020
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
XPDITE GROUP LLC (104)303/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
L&J PLG & HTG CO OF NY INPlumbing407/08/2026
SYMMETRICAL CONSTRUC CORPGeneral Contractor304/09/2026
JOE MIDDLETONElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
JOSE A SANTOS PE, PC3292103/09/2020
Building Lifecycle
All (14)Filed (3)Permit Issued (3)Signed Off (1)Violation (1)Objection (4)Special Inspection (2)
02/18/2026
Signed off — Alteration
M00271672-I1
08/11/2020
Permit issued — Mechanical Systems
M00322668-I1-MS
07/27/2020
Objection raised — Other
07/27/2020
Objection resolved — Addressed
07/20/2020
Objection raised — Other
07/20/2020
Objection resolved — Addressed
03/09/2020
Filed — Alteration
Install HVAC system in exisiting commercial space
M00322668-I1
02/26/2020
Special inspection requirement — Mechanical Systems
Jose Santos
02/26/2020
Special inspection requirement — Final
Rilder Mejia
02/14/2020
Permit issued — Construction Fence
M00271672-I1-FN
01/31/2020
Permit issued — Plumbing
M00271723-I1-PL
01/23/2020
Filed — Alteration
M00271672-I1
01/23/2020
Filed — Alteration
Install 4 new sprinkler heads
M00271723-I1
04/08/2016
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedSYMMETRICAL CONSTRUC CORP08/11/2020
DOB NOWConstruction FenceSigned-offSYMMETRICAL CONSTRUC CORP02/14/2020
DOB NOWPlumbingPermit IssuedL&J PLG & HTG CO OF NY IN01/31/2020
BISOTISSUEDSYMMETRICAL CONSTRUC CORP12/02/2021
BISOTISSUEDSYMMETRICAL CONSTRUC CORP01/27/2021
BISOTISSUEDSYMMETRICAL CONSTRUC CORP07/10/2020
BISOTISSUEDH&K NY CORP03/23/2017
1 project · most recent 03/09/2020
Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
03/09/2020Permit IssuedSYMMETRICAL CONSTRUC CORPAir Conditioning Systems
Cooling
Midea MODEL #DLCLRAH48AAK 4 tons · Split System ×1
MOEDL #DLFLDAH48XAK 4 tons ×1
1 project · most recent 01/23/2020
Plumbing-Sprinkler
FiledStatusContractorScope
01/23/2020Permit IssuedL&J PLG & HTG CO OF NY INPlumbing-Sprinkler
2 projects · most recent 02/04/2020
General Wiring
FiledStatusContractorScope
02/04/2020CompleteJOSEPH WEINSTEIN ELECTRICGeneral Wiring
05/31/2018Permit IssuedY.S ELECTRICGeneral Wiring
▾Special Inspection Requirements (DOB NOW) — 2
DateRequirementInspectorRole
02/26/2020Mechanical SystemsJose Santosspecial
02/26/2020FinalRilder Mejiaprogress
▾Documents — 45 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch - Construction Fence1
09/05/2026M00271672-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Plumbing1
09/05/2026M00271723-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Mechanical Systems1
08/15/2026M00322668-I1Request digital key ↗
▸Applications & Permits6
▸BISPLAN / WORK APPROVAL APPLICATION3
10/11/2019123818164Open ↗
09/11/2019123818164Open ↗
03/30/2017123015003Open ↗
▸BISWORK PERMIT APPLICATION3
01/28/2021123818164Open ↗
12/20/2019123818164Open ↗
03/30/2017123015003Open ↗
▸Seals & Professional Certifications13
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION5
12/20/2019123818164Open ↗
12/20/2019123818164Open ↗
09/11/2019123818164Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
09/05/2026M00271672-I1Open ↗
09/05/2026M00271723-I1Open ↗
09/05/2026M00322668-I1Open ↗
Showing 3 of 4 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
03/30/2017123015003Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
03/30/2017123015003Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/28/2026M00322668-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
08/28/2026M00322668-I1Open ↗
▸Safety & Tenant Protection4
▸DOB NOWTenant Protection Plan3
08/13/2026M00271672-I1Open ↗
08/13/2026M00271723-I1Open ↗
08/13/2026M00322668-I1Open ↗
▸BISTenant Protection Plan and Notes1
09/11/2019123818164Open ↗
▸Environmental & Asbestos8
▸BISASBESTOS: CERTIFICATION (DEP ACP5)2
10/11/2019123818164Open ↗
03/30/2017123015003Open ↗
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
09/05/2026M00271723-I1Open ↗
08/13/2026M00322668-I1Open ↗
▸DOB NOWOER: Notice to Proceed2
08/13/2026M00271672-I1Open ↗
08/13/2026M00271723-I1Open ↗
▸BISENVIRONMENTAL RESTRICTIONS - OER NOTICE OF SATISFACTION1
02/18/2026123818164Open ↗
▸BISENVIRONMENTAL RESTRICTIONS - OER NOTICE TO PROCEED1
11/22/2019123818164Open ↗
▸Energy Compliance4
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS3
09/11/2019123818164Open ↗
05/08/2017123015003Open ↗
03/30/2017123015003Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
05/08/2017123015003Open ↗
▸Cost, Insurance & Ownership4
▸BISCOST AFFIDAVIT3
09/11/2019123818164Open ↗
05/08/2017123015003Open ↗
03/30/2017123015003Open ↗
▸BISHIC LICENSE OR AFFIDAVIT1
12/20/2019123818164Open ↗
▸Filing & Intake Forms2
▸BISEFILING COVER SHEET2
09/11/2019123818164Open ↗
03/30/2017123015003Open ↗
▸Other Documents1
▸DOB NOWWaiver Document1
08/15/2026M00322668-I1Open ↗