← Back
Miscellaneous hospital / health care facility
2015 MADISON AVENUE
MANHATTAN · East Harlem (North) · BIN 1054181
💬 Discuss this project
1991Year Built
4Stories
I9Building Class
R7AZoning
19,500 sfGross Floor Area
20Units
10 Open Violations 5 unresolved · 5 paperwork only ▸
Miscellaneous hospital / health care facility · Owner of record: ARGUS COMMUNITY INC. · 10,990 sf lot · 1.77 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbingFire ProtectionGeneral
Roof1p · 1 filing · 7 docs
Floor 41p · 1 filing · 7 docs
Floor 31p · 1 filing · 7 docs
Floor 21p · 1 filing · 7 docs
Floor 11p · 1 filing · 7 docs
Cellar17p · 3 filings · 20 docs
Filed — no permit issued60p · 1 filing · 17 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
ARGUS COMMUNITY INC3103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
02/09/2018$1.6M—ADDICTS REHABILITATION CENTER FUND INC. → ARGUS COMMUNITY INC.$84/sf building
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
POSEN ARCHITECTS903/21/2026
NEW YORK ENGINEERING ASSOCIATES P203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ARISTON CHIMNEY LLCGeneral Contractor303/21/2026
VITO INGRAVALLOElectrical203/21/2026
SANTI LEMBO PLBG & HTGPlumbing207/08/2026
GALAXY ELECTRIC CORP 004690General Contractor103/22/2026
SENID PL & HTG CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
A TECH ENGINEERING NYC, P6738412/16/2021
NEW YORK ENGINEERING ASSO851109/15/2021
Building Lifecycle
All (118)Filed (10)Permit Issued (4)Signed Off (1)Violation (60)Objection (13)Special Inspection (30)
04/20/2026
Objection resolved — Resolved
04/20/2026
Objection resolved — Resolved
04/20/2026
Objection resolved — Resolved
04/20/2026
Objection resolved — Resolved
03/26/2026
Objection resolved — Resolved
03/24/2026
Objection raised — Fire_Protection
03/24/2026
Objection resolved — Resolved
03/23/2026
Objection raised — Scope
03/23/2026
Objection raised — Structural
03/23/2026
Objection raised — Admin
03/23/2026
Objection raised — Scope
03/23/2026
Objection raised — Admin
03/23/2026
Objection raised — Admin
03/13/2026
Filed — Alteration
Structural reinforcing and support for new duct & shaft openings throughout the building & support for new mech. roof curbs for new mech. equip. Approx. 942 sq.ft. total of openings and curbs throughout.
M01333203-S2
03/13/2026
Filed — Alteration
Structural reinforcing and support for new duct & shaft openings throughout the building & support for new mech. roof curbs for new mech. equip. Approx. 942 sq.ft. total of openings and curbs throughout.
M01333203-S3
03/13/2026
Filed — Alteration
Structural reinforcing and support for new duct & shaft openings throughout the building & support for new mech. roof curbs for new mech. equip. Approx. 942 sq.ft. total of openings and curbs throughout.
M01333203-S1
03/13/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
03/13/2026
Special inspection requirement — Ventilation and air distribution system
03/13/2026
Special inspection requirement — Duct leakage testing, insulation and design
03/13/2026
Special inspection requirement — Maintenance information
03/13/2026
Special inspection requirement — HVAC-R and service water heating system controls
03/13/2026
Special inspection requirement — HVAC-R and service water heating equipment
03/13/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
03/13/2026
Special inspection requirement — Heating Systems
03/13/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
03/12/2026
Filed — Alteration
Structural reinforcing and support for new duct & shaft openings throughout the building & support for new mech. roof curbs for new mech. equip. Approx. 942 sq.ft. total of openings and curbs throughout.
M01333203-S4
03/12/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
03/12/2026
Special inspection requirement — Post-installed Anchors
03/12/2026
Special inspection requirement — Structural Steel - Welding
03/12/2026
Special inspection requirement — Structural Steel - High Strength Bolting
03/12/2026
Special inspection requirement — Structural Steel - Details
03/09/2026
Filed — Alteration
Structural reinforcing and support for new duct & shaft openings throughout the building & support for new mech. roof curbs for new mech. equip. Approx. 942 sq.ft. total of openings and curbs throughout.
M01333203-I1
03/09/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
03/03/2026
Special inspection requirement — Insulation placement and R values
03/03/2026
Special inspection requirement — Vestibules
03/03/2026
Special inspection requirement — Lighting controls
03/03/2026
Special inspection requirement — Fenestration air leakage
03/03/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
03/03/2026
Special inspection requirement — Interior lighting power
02/27/2026
Special inspection requirement — Final
02/27/2026
Special inspection requirement — Sprinkler Systems
02/27/2026
Special inspection requirement — Standpipe Systems
12/17/2025
Special inspection requirement — Mechanical Systems
12/17/2025
Special inspection requirement — Final
12/12/2025
Special inspection requirement — Energy Code Compliance Inspections
12/12/2025
Special inspection requirement — Final
12/12/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
12/12/2025
Special inspection requirement — Fire-Resistance Rated Construction
04/16/2025
Violation issued (HPD, closed)
C
05/30/2024
Violation issued (ECB, open)
Construction
05/30/2024
Violation issued (ECB, open)
Construction
06/30/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/30/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/24/2022
Violation issued (ECB, open)
Elevators
12/16/2021
Filed — Alteration
The removal of existing boilers and their replacement with new boilers including all piping and connections as required to properly install and operate the new boilers
M00324416-P1
12/16/2021
Filed — Alteration
Replacement of the existing water heater with new. including all branch piping, gas piping valves and connections as needed for proper installation. No change to use egress or occupancy.
M00325902-P1
11/02/2021
Signed off — Alteration
INSTALL CHIMNEY LINER AND COMBUSTION AIR INTAKE DUCTS PER PLANS.
M00578125-I1
09/29/2021
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/24/2021
Permit issued — Mechanical Systems
M00578125-I1-MS
09/15/2021
Filed — Alteration
INSTALL CHIMNEY LINER AND COMBUSTION AIR INTAKE DUCTS PER PLANS.
M00578125-I1
Latest 60 of 118 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offARISTON CHIMNEY LLC09/24/2021
DOB NOWBoiler EquipmentSigned-offSENID PL & HTG CORP05/28/2021
DOB NOWBoiler EquipmentSigned-offSANTI LEMBO PLBG & HTG08/12/2020
DOB NOWPlumbingPermit IssuedSANTI LEMBO PLBG & HTG08/12/2020
BIS—ISSUEDJULIUS G. PERRY,ARCHITECT04/14/2016
BISFPISSUEDSENTINEL FIRE CONTROL INC11/06/1992
BISEQRE-ISSUEDREGIONAL SCAFFOLD EQUIPMENT CORP12/05/1991
2 projects · most recent 03/13/2026
Gas Storm Water/Sanitary
FiledStatusContractorScope
03/13/2026——Gas, Storm, Water/Sanitary
12/16/2021Permit IssuedSANTI LEMBO PLBG & HTGGas
2 projects · most recent 03/11/2022
General Wiring
FiledStatusContractorScope
03/11/2022CompleteGALAXY ELECTRIC CORPGeneral Wiring
11/13/2019Permit IssuedROMCON ELECTRIC, INCGeneral Wiring
1 project · most recent 03/13/2026
Steel Concrete
FiledStatusContractorScope
03/13/2026——Steel, Concrete
▾Special Inspection Requirements (DOB NOW) — 59
DateRequirementInspectorRole
03/13/2026Fire-Resistant Penetrations and Joints—special
03/13/2026Ventilation and air distribution system—energy_progress
03/13/2026Duct leakage testing, insulation and design—energy_progress
03/13/2026Maintenance information—energy_progress
03/13/2026HVAC-R and service water heating system controls—energy_progress
03/13/2026HVAC-R and service water heating equipment—energy_progress
03/13/2026HVAC-R and service water piping design and insulation—energy_progress
03/13/2026Heating Systems—special
03/13/2026Fire-Resistant Penetrations and Joints—special
03/12/2026Structural Stability – Alterations of existing buildings—special
03/12/2026Post-installed Anchors—special
03/12/2026Structural Steel - Welding—special
03/12/2026Structural Steel - High Strength Bolting—special
03/12/2026Structural Steel - Details—special
03/09/2026Fire-Resistant Penetrations and Joints—special
03/03/2026Insulation placement and R values—energy_progress
03/03/2026Vestibules—energy_progress
03/03/2026Lighting controls—energy_progress
03/03/2026Fenestration air leakage—energy_progress
03/03/2026Fenestration and door U-factor and product ratings—energy_progress
03/03/2026Interior lighting power—energy_progress
02/27/2026Final—progress
02/27/2026Sprinkler Systems—special
02/27/2026Standpipe Systems—special
12/17/2025Mechanical Systems—special
Latest 25 of 59.
▾Documents — 87 on file (BIS + DOB NOW)
▸Plans & Drawings10
▸DOB NOWPlans/Sketch6
09/03/2026M00578125-I1Request digital key ↗
08/18/2026M01333203-I1Request digital key ↗
08/18/2026M01333203-S3Request digital key ↗
Showing 3 of 6 on file for this type
▸DOB NOWPlans/Sketch - Boiler Equipment2
09/03/2026M00324416-I1Request digital key ↗
08/15/2026M00324416-P1Request digital key ↗
▸DOB NOWPlans/Sketch - Plumbing2
09/03/2026M00325902-I1Request digital key ↗
08/15/2026M00325902-P1Request digital key ↗
▸Applications & Permits5
▸BISPLAN / WORK APPROVAL APPLICATION3
09/22/2016122885921Open ↗
04/14/2016121555370Open ↗
03/26/2013121555370Open ↗
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION1
04/21/2016121555370Open ↗
▸BISWORK PERMIT APPLICATION1
04/19/2016121555370Open ↗
▸Zoning, Tax Lot & Property Records1
▸BISZONING DIAGRAM1
01/07/2016121555370Open ↗
▸Seals & Professional Certifications41
▸DOB NOWProgress Inspector Seal & Signature21
09/23/2026M00324416-I1Open ↗
09/23/2026M00324416-I1Open ↗
09/23/2026M00324416-I1Open ↗
Showing 3 of 21 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature10
08/18/2026M01333203-S4Open ↗
08/18/2026M01333203-S3Open ↗
08/18/2026M01333203-I1Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature8
09/23/2026M00324416-I1Open ↗
09/23/2026M00324416-I1Open ↗
08/29/2026M00578125-I1Open ↗
Showing 3 of 8 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION2
01/27/2016121555370Open ↗
01/27/2016121555370Open ↗
▸Trade Schedules & Equipment4
▸BISFA - FDNY APPROVAL : FD-FAA4
03/13/2017121555370Open ↗
03/13/2017121555370Open ↗
03/13/2017122885921Open ↗
Showing 3 of 4 on file for this type
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/13/2026M00578125-I1Open ↗
▸Approvals, Objections & Sign-offs12
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter5
08/13/2026M00325902-P1Open ↗
08/13/2026M00324416-I1Open ↗
08/13/2026M00325902-I1Open ↗
Showing 3 of 5 on file for this type
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST3
06/16/2017121555370Open ↗
06/14/2017121555370Open ↗
05/24/2017121555370Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION2
12/21/2015121555370Open ↗
12/21/2015121555370Open ↗
▸BISSCHEDULE A - OCCUPANCY / USE1
03/26/2013121555370Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
04/02/2012121021081Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
04/02/2012121021081Open ↗
▸Filing & Intake Forms6
▸BISADDITIONAL INFORMATION3
04/14/2016121555370Open ↗
12/21/2015121555370Open ↗
12/21/2015121555370Open ↗
▸BISEFILING COVER SHEET3
09/22/2016122885921Open ↗
03/26/2013121555370Open ↗
04/02/2012121021081Open ↗
▸Other Documents6
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION3
06/17/2016121555370Open ↗
01/08/2016121555370Open ↗
04/02/2012121021081Open ↗
▸BISSupporting Document: Fee Deferment1
09/22/2016122885921Open ↗
▸BISPLOT DIAGRAM1
12/21/2015121555370Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/18/2026M01333203-I1Open ↗