| Owner | Filings | Most Recent |
|---|---|---|
| SAINT THOMAS CHURCH | 19 | 09/13/2026 |
| ST. THOMAS CHURCH/ ETC. | 1 | 03/22/2026 |
| ST THOMAS CHURCH | 9 | 03/22/2026 |
| Firm | Filings | Most Recent |
|---|---|---|
| ALTIERI SEBOR WIEBER LLC | 9 | 07/29/2026 |
| FZAD | 3 | 04/01/2025 |
| Representative | Filings | Most Recent |
|---|---|---|
| FZAD ARCHITECTURE + DESIGN | 8 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| ELITE HYDRA INC | General Contractor | 2 | 07/08/2026 |
| LOCKER, WAYNE | Electrical | 1 | 03/21/2026 |
| WAYNE LOCKER | Electrical | 1 | 03/21/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| CDG ARCHITECTS LLC /DBA: | 1327 | 2 | 07/29/2026 |
| FZAD ARCHITECTURE + DESIG | 2041 | 5 | 07/29/2026 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Mechanical Systems | Permit Issued | ELITE HYDRA INC | 07/03/2025 |
| DOB NOW | Suspended Scaffold | Signed-off | VERTICAL ACCESS LLC | 07/01/2025 |
| DOB NOW | General Construction | Permit Issued | ELITE HYDRA INC | 06/26/2025 |
| BIS | FP | ISSUED | SENTINEL FIRE SAFETY CORP | 10/24/2016 |
| BIS | EQ | ISSUED | COLGATE SCAFFOLDING | 06/19/1997 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 07/29/2026 | Permit Issued | ELITE HYDRA INC | Heating Systems, Ventilation Systems | Heating Ventilation Greenheck SQ-80-VG 150 CFM · Exhaust Fan ×6 USF-24 7,000 CFM · Kitchen Exhaust ×6 CUE-100-VG 1,468 CFM · Exhaust Fan ×3 CUE-100HP-VG 250 CFM · Exhaust Fan ×3 G-090-VG 665 CFM · Exhaust Fan ×3 G-098-VG 400 CFM · Exhaust Fan ×3 G-099-VG 591 CFM · Kitchen Exhaust ×3 G-130-VG 1,761 CFM · Exhaust Fan ×3 G-140-VG 1,930 CFM · Exhaust Fan ×3 G-160-VG 3,800 CFM · Exhaust Fan ×3 G-90-VG 420 CFM · Exhaust Fan ×3 QEID-12 800 CFM · Exhaust Fan ×3 |
| 03/04/2025 | — | — | Heating Systems, Ventilation Systems | Heating Trane D5WB 244,000 BTU ×3 Ventilation Greenheck G-090-VG 420 CFM · Exhaust Fan ×1 G-143-VG 1,775 CFM · Exhaust Fan ×1 G-180-20 3,800 CFM · Exhaust Fan ×1 SWB-222-30 6,000 CFM · Exhaust Fan ×1 Loren Cook 20CV 5,000 CFM · Exhaust Fan ×1 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 10/01/2024 | — | — | Gas |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 08/25/2026 | Post-installed Anchors | Yongho Kim | special |
| 08/25/2026 | HVAC-R and service water piping design and insulation | JOSEPH YOUNG | energy_progress |
| 08/25/2026 | HVAC-R and service water heating system controls | JOSEPH YOUNG | energy_progress |
| 08/25/2026 | Maintenance information | JOSEPH YOUNG | energy_progress |
| 08/25/2026 | HVAC-R and service water heating equipment | JOSEPH YOUNG | energy_progress |
| 08/25/2026 | Energy Code Compliance Inspections | JOSEPH YOUNG | progress |
| 08/25/2026 | Final | JOSEPH YOUNG | progress |
| 08/25/2026 | Tenant Protection Plan Compliance | Frederic Zonsius | special |
| 08/25/2026 | Fire-Resistant Penetrations and Joints | Yongho Kim | special |
| 08/25/2026 | Mechanical Systems | Yongho Kim | special |
| 01/20/2026 | Fire-Resistant Penetrations and Joints | Yongho Kim | special |
| 01/20/2026 | HVAC-R and service water heating equipment | JOSEPH YOUNG | energy_progress |
| 01/20/2026 | HVAC-R and service water heating system controls | JOSEPH YOUNG | energy_progress |
| 01/20/2026 | HVAC-R and service water piping design and insulation | JOSEPH YOUNG | energy_progress |
| 01/20/2026 | Maintenance information | JOSEPH YOUNG | energy_progress |
| 01/20/2026 | Final | JOSEPH YOUNG | progress |
| 01/20/2026 | Energy Code Compliance Inspections | JOSEPH YOUNG | progress |
| 01/20/2026 | Tenant Protection Plan Compliance | Frederic Zonsius | special |
| 01/20/2026 | Post-installed Anchors | Yongho Kim | special |
| 01/20/2026 | Mechanical Systems | Yongho Kim | special |
| 05/20/2025 | Fire-Resistance Rated Construction | Frederic Zonsius | progress |
| 05/20/2025 | Tenant Protection Plan Compliance | Frederic Zonsius | special |
| 05/20/2025 | Final | Frederic Zonsius | progress |
| 05/20/2025 | Energy Code Compliance Inspections | Frederic Zonsius | progress |
| 05/20/2025 | Interior lighting power | Frederic Zonsius | energy_progress |
| Tenant | Space | Floors | Renovation projects |
|---|---|---|---|
| St. Thomas Choir School | Education | — | Project M01236474 Project M01076349 Project M00620276 |