ECB04/30/2026PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATIONS.AT TIME OF INSPECTION,I OBSERVED SIDEWALK SHED IN PLACE AT EXPOSURE#4,MISSING CAPS FROM THE BOLTS.THIS CREATES SHARP EDGES.CAUSING HAZARDOUS CONDITIONS FO$2K due
ECB04/30/2026MISCELLANEOUS VIOLATIONS.AT TIME OF INSPECTION,I OBSERVED AT PREMISES SUPPORTED SCAFFOLDS INSTALLED AT EXP#3 WERE MISSING PLANKS,TOP-RAILS AND MID-RAILS.CREATING UNSAFE CONDITIONS FOR CONSTRUCTION PERSONNEL WOR$2K due
ECB06/25/2026DURING INSPECTION OF AN ACTIVE SCHOOL WITH SIDEWALK SHED AROUND THE PERMITTER, DOB RECORDS REVEALED THAT THE PERMITS FOR THE SHED AND ELECTRICAL WERE BOTH EXPIRED WITH NO RENEWAL IN THE PROCESS. PERMITS MUST BEHearing held — result not yet published$1K proposed
ECB06/01/2026REISSUE#35725596X FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED:ROOF LEVEL STAIRCASE BULKHEAD HAS CRACKS IN CEILING.REM:REPAIRAND/OR REPLACE.Nothing owed — awaiting certificate of correction
ECB06/01/2026REISSUE#35715592Z FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED:FPSC INTERIOR DOORS DO NOT SELF-CLOSE PROPERLY AT CAFETERIA STAIRCASE EXIT#2.CLASSROOM DOORS DO NOT SELF-CLOSE PROPERLY AT 2ND FLR RNothing owed — awaiting certificate of correction
ECB10/20/2025FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: SMOKE DOOORS NOT SELF-CLOSING, BINDING AND MISSING 1 MISSING DOOR EXIT 3 STAIRA, 1 SMOKE DOOR NOT CLOSING PROPERLY EXIT 2 1ST FL, 1ST FL, 1 SMOKE DONothing owed — awaiting certificate of correction
ECB10/20/2025FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: MISSING PERMANENT GUARD RAILS AND PANELS AROUND SEVERAL LOCATIONS THROUGHOUT ROOF REMOVED AND NOT PUT BACK. REMEDY: REPAIR AND/OR REPLACE.Nothing owed — awaiting certificate of correction
ECB10/20/2025FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: STEP CRACKS ON ROOF BULKHEAD. REMEDY: REPAIR AND/OR REPLACE.Nothing owed — awaiting certificate of correction
ECB04/06/2024WORK WITHOUT AN AFTER HOURS VARIANCE: AT THE EXPOSURE 1/4 CORNER WORKERS WERE ASSEMBLING REBAR FOR CONCRETE WORK AT TIME OF INSPECTION, OBTAIN AFTER HOURS VARIANCE; STOP ALL CONCRETE WORK, OBTAIN VARIANCENothing owed — awaiting certificate of correction
ECB06/06/2022REISSUE#35577139Z FAILURE TO MAINTAIN BUILDING WALL(S)OR APPURTENANCESNOTED:OBSERVED AT(CELLAR LEVEL)BOILER ROOM,FOUNDATION WALLS HAVE BECOME POROUS ALLOWING WATER TO PENETRATE THROUGH SOUTH SIDE WALL OF THE BONothing owed — awaiting certificate of correction
ECB05/19/2021REISSUE35495564K FAILURE TO MAINTAIN BLDG WALL(S) OR APPURTENANCES.OBSERVED:@CELLAR LEVEL FOUNDATION WALLS HAVE BECOME POROUS ALLOWING WATERPENETRATION@S SIDE BOILERRM.MAINTAIN EXTERIOR BLDG WALL.Nothing owed — awaiting certificate of correction
ECB05/19/2020RESISUE #35221601M FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES NOTED AT CELLAR FOUNDATION WALLS HAS BECOME POROUS ALLOWING THE WATER PENETRATION AT SOUTH SIDENothing owed — awaiting certificate of correction
ECB06/10/2019REISSUE #35331772Y NOTED:AT CELLAR LEVEL WATER PENETRATION AT MULTIPLE AREAS INTERIOR DAMAGES ON FOUNDATION ADJACENT TO HOIST LEVEL COAL CHATE AT PS 134 MAINTAIN EXTERIOR BUILDING WALLNothing owed — awaiting certificate of correction
ECB06/21/2018REISSUE #35272401H (07/11/17) FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES: WATER PENETRATION INTO CELLAR AT MULTIPLE AREA CAUSING INTERIOR DAMAGES ON FOUNDATION. ADJACENT TO HOIST/COAL CHUTE (ASH)RMDYNothing owed — awaiting certificate of correction
ECB07/11/2017REISSUE#35221601M FAILURE TO MAINTAIN BLDG WALLS OR APPURTENANCES,WATER PENETRATION INTO CELLAR AT MULTIPLE AREAS CAUSING INTERIOR DAMAGES. REMEDY: MAINTAIN BLDG WALLS.Nothing owed — awaiting certificate of correction
ECB11/17/2016REISSUE #35099940K FAILURE TO MAINTAIN BLDG WALLS OR APPURTENANCES. NOTED: WATER PENETRATION INTO CELLAR AT MULTIPLE AREAS HOIST CAUSING INTERIOR DAMAGES. FOUNDATION WALL HAS BECOME POROUS,APPROX 2"WATER PUDDLENothing owed — awaiting certificate of correction
ECB06/27/2014RE-ISSUE # 35027770Y. WATER PENETRATION INTO CELLAR AT MULTIPLE AREAS HOIST, ADJACENT TO BLOWERS, WEST WALL. REMEDY: SEAL PENETRATION.Nothing owed — awaiting certificate of correction
ECB04/26/2012REISSUE#34918605N.FOUNDATION WALL HAS CRACKS & HAS BECOME POROUS IN SEVERAL LOCATIONS OF CELLAR ALLOWING WATER PENETRATION.REM:REPAIR FOUNDATION WALL PROVIDE WATER PROOFING.Nothing owed — awaiting certificate of correction
ECB07/05/2011REISSUE: 34840575Y EXTERIOR FOUNDATION WALL HAS BECOME POROUS & ALLOWING RAIN WATER INTO THE ASH HOIST AREA AT CELLAR LEVEL CAUSING INTERIORDAMAGES. REMEDY: WATER PROOF FOUNDATION WALL.Nothing owed — awaiting certificate of correction
ECB07/05/2011REISSUE: 34840576X THE CONCRETE CEILING BY THE ASH HOIST INSIDE BOILER ROOM AT CELLAR LEVEL IS CRACKED. REMEDY: REPAIR &/OR REPLACE CONCRETE CEILING.Nothing owed — awaiting certificate of correction
ECB06/30/2009RE 34712513M 34519109X 34563969Y 34481988K WATER PENETRATION THROUGH FOUNDATION WALL THROUGHOUT AROUND PIP PENETRATIONS AND CHUTE REM: SEAL ALL PENETRATIONSNothing owed — awaiting certificate of correction
ECB10/29/2008REISSUE: 34519109X FOUNDATION WALL HAS BECOME POROUS AND ALLOWING RAINWATER INTO THE BUILDING LOCATED AT THE SOUTH SIDE AT CELLAR LEVEL. REMDY: WATER PROOF EXTERIOR FOUNDATION WALL.Nothing owed — awaiting certificate of correction
ECB03/14/2007FAILURE TO MAINTAIN-EXTERIOR.REISSUE 34481988K,34519109X. WATER PENETRATION THROUGH EXTERIOR WALL. BASEMENT-WEST WALL OF COAL VAULT. SOUTH WALL TO BOILER ROOM.REMEDY:STOP WATER PENETRATION.Nothing owed — awaiting certificate of correction
ECB04/11/2006REISSUE VI 34481988K WATER PENETRATION THROUGH EXTERIOR WALL LOCATION BSMT WEST WALL OF COAL VAULT & SOUTH WALL OF BOILER ROOM.REMEDY:WATER ROOF AREASNothing owed — awaiting certificate of correction
Public elementary, junior or senior high · Owner of record: NYC DEPARTMENT OF EDUCATION · 68,000 sf lot · 1.59 FAR built · Flood zone X