← Back
Three families
2030 EAST 18 STREET
BROOKLYN · BIN 3198193
💬 Discuss this project
1930Year Built
2Stories
C0Building Class
R5Zoning
4,545 sfGross Floor Area
3Units
Rent Stabilized0 Open Violations
Three families · Owner of record: MAX OUT ACQUISITIONS LLC · 3,600 sf lot · 1.26 FAR built · Flood zone X
Locations of Work
ArchitectureElectricalMechanicalPlumbing
Permit Issued — active, not yet Signed-off
Floor 2Under Construction4p · 1 filing · 14 docs
Floor 1Under Construction4p · 1 filing · 14 docs
CellarUnder Construction6p · 1 filing · 14 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
INNOSPARK DESIGN309/15/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
06/26/2025$1.3M—— → —$281/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
AARON MCDONALD ARCHITECT309/09/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
NY BUILDING ASSOCIATES INGeneral Contractor106/27/2026
W.R. PLBG AND HTG CORPPlumbing106/27/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
AARON MCDONALD ARCHITECT5118309/09/2026
Building Lifecycle
All (34)Filed (3)Permit Issued (2)Violation (9)Special Inspection (20)
09/09/2026
Filed — Alteration
INSTALL NEW BOILER, H.W.H.,BATHROOM AND KITCHEN FIXTURES IN THE EXISTING 2 STORY BUILDING. PLUMBING WORKS AS PER PLAN. NO CHANGE IN EGRESS, USE, OR OCCUPANCY.
B01415243-P1
09/09/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Aaron McDonald
09/09/2026
Special inspection requirement — Energy Code Compliance Inspections
Aaron McDonald
09/09/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Aaron McDonald
09/09/2026
Special inspection requirement — HVAC-R and service water heating equipment
Aaron McDonald
09/09/2026
Special inspection requirement — HVAC-R and service water heating system controls
Aaron McDonald
06/25/2026
Permit issued — Plumbing
B01415243-S1-PL
06/24/2026
Permit issued — Mechanical Systems
B01415243-I1-GC-CX
06/23/2026
Filed — Alteration
INSTALL NEW BOILER, H.W.H.,BATHROOM AND KITCHEN FIXTURES IN THE EXISTING 2 STORY BUILDING. PLUMBING WORKS AS PER PLAN. NO CHANGE IN EGRESS, USE, OR OCCUPANCY.
B01415243-S1
06/17/2026
Filed — Alteration
INSTALL NEW BOILER, H.W.H.,BATHROOM AND KITCHEN FIXTURES IN THE EXISTING 2 STORY BUILDING. PLUMBING WORKS AS PER PLAN. NO CHANGE IN EGRESS, USE, OR OCCUPANCY.
B01415243-I1
06/11/2026
Special inspection requirement — Maintenance information
Aaron McDonald
06/11/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Aaron McDonald
06/11/2026
Special inspection requirement — Interior lighting power
Aaron McDonald
06/11/2026
Special inspection requirement — Insulation placement and R values
Aaron McDonald
06/11/2026
Special inspection requirement — Energy Code Compliance Inspections
Aaron McDonald
06/11/2026
Special inspection requirement — Fire-Resistance Rated Construction
Aaron McDonald
06/11/2026
Special inspection requirement — Air barrier - visual inspection
Aaron McDonald
06/11/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
Aaron McDonald
06/11/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Aaron McDonald
06/11/2026
Special inspection requirement — Fenestration air leakage
Aaron McDonald
06/11/2026
Special inspection requirement — Fenestration areas
Aaron McDonald
06/11/2026
Special inspection requirement — HVAC-R and service water heating equipment
Aaron McDonald
06/11/2026
Special inspection requirement — HVAC-R and service water heating system controls
Aaron McDonald
06/10/2026
Special inspection requirement — Final
Aaron McDonald
06/10/2026
Special inspection requirement — Mechanical Systems
Aaron McDonald
06/09/2025
Violation issued (HPD, closed)
A
11/29/2024
Violation issued (HPD, closed)
I
04/09/2024
Violation issued (HPD, closed)
A
11/22/2023
Violation issued (HPD, closed)
I
03/22/2023
Violation issued (HPD, closed)
A
02/24/2022
Violation issued (HPD, closed)
A
02/24/2022
Violation issued (HPD, closed)
I
04/08/2021
Violation issued (HPD, closed)
A
10/08/2015
Violation issued (HPD, closed)
I
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedW.R. PLBG AND HTG CORP06/25/2026
DOB NOWMechanical SystemsPermit IssuedNY BUILDING ASSOCIATES IN06/24/2026
1 project · most recent 09/09/2026
Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
09/09/2026Permit IssuedNY BUILDING ASSOCIATES INAir Conditioning Systems
Cooling
Daikin 3MXS24WMVJU9 36,000 BTU · Condensing Unit ×2
4MXS36RMVJUA 24,000 BTU · Condensing Unit ×2
1 project · most recent 09/09/2026
Gas Water/Sanitary
FiledStatusContractorScope
09/09/2026Permit IssuedW.R. PLBG AND HTG CORPGas, Water/Sanitary
1 project · most recent 07/28/2026
General Wiring
FiledStatusContractorScope
07/28/2026Permit IssuedKJK ELECTRIC INCGeneral Wiring
▾Special Inspection Requirements (DOB NOW) — 20
DateRequirementInspectorRole
09/09/2026Fire-Resistant Penetrations and JointsAaron McDonaldspecial
09/09/2026Energy Code Compliance InspectionsAaron McDonaldprogress
09/09/2026HVAC-R and service water piping design and insulationAaron McDonaldenergy_progress
09/09/2026HVAC-R and service water heating equipmentAaron McDonaldenergy_progress
09/09/2026HVAC-R and service water heating system controlsAaron McDonaldenergy_progress
06/11/2026Maintenance informationAaron McDonaldenergy_progress
06/11/2026Fire-Resistant Penetrations and JointsAaron McDonaldspecial
06/11/2026Interior lighting powerAaron McDonaldenergy_progress
06/11/2026Insulation placement and R valuesAaron McDonaldenergy_progress
06/11/2026Energy Code Compliance InspectionsAaron McDonaldprogress
06/11/2026Fire-Resistance Rated ConstructionAaron McDonaldprogress
06/11/2026Air barrier - visual inspectionAaron McDonaldenergy_progress
06/11/2026Fenestration and door U-factor and product ratingsAaron McDonaldenergy_progress
06/11/2026HVAC-R and service water piping design and insulationAaron McDonaldenergy_progress
06/11/2026Fenestration air leakageAaron McDonaldenergy_progress
06/11/2026Fenestration areasAaron McDonaldenergy_progress
06/11/2026HVAC-R and service water heating equipmentAaron McDonaldenergy_progress
06/11/2026HVAC-R and service water heating system controlsAaron McDonaldenergy_progress
06/10/2026FinalAaron McDonaldprogress
06/10/2026Mechanical SystemsAaron McDonaldspecial
▾Documents — 14 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/16/2026B01415243-S1Request digital key ↗
08/16/2026B01415243-I1Request digital key ↗
▸Seals & Professional Certifications9
▸DOB NOWProgress Inspector Seal & Signature4
09/23/2026B01415243-P1Open ↗
09/23/2026B01415243-P1Open ↗
09/01/2026B01415243-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature3
09/15/2026B01415243-P1Open ↗
08/16/2026B01415243-I1Open ↗
08/16/2026B01415243-S1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
09/23/2026B01415243-P1Open ↗
09/01/2026B01415243-I1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
09/15/2026B01415243-P1Open ↗
08/16/2026B01415243-S1Open ↗
08/16/2026B01415243-I1Open ↗