← Back
Predominantly retail with other uses
204 5 AVENUE
MANHATTAN · BIN 1015620
💬 Discuss this project
1930Year Built
7Stories
K4Building Class
C5-2Zoning
25,094 sfGross Floor Area
2Units
3 Open Violations 2 unresolved · 1 paperwork only ▸FDNY Report ↗
Predominantly retail with other uses · Owner of record: PORVEN REAL ESTATE, INC. · 5,115 sf lot · 4.91 FAR built · Flood zone X
Locations of Work
Fire Protection
Permit Issued — active, not yet Signed-off
RoofUnder Construction1 filing · 9 docs
Floor 41 filing · 7 docs
Floor 31 filing · 7 docs
Floor 2
Floor 1
Sub-Basement1 filing · 7 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
PORVEN2608/26/2026
CEPRINE CONSTRUCTION807/08/2026
PORCELANOSA507/08/2026
PENTAGRAM DESIGN103/22/2026
RONORNA REALTY CORP103/22/2026
OWNER:204 5TH AVE103/22/2026
OWNER OF PREMISES103/22/2026
PORVEN REAL ESTATE1603/21/2026
204 FIFTH AVENUE403/21/2026
RONORNA REALTY C O VOULEZ VOUS203/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
WELLWORTH CONSULTING LLC504/17/2026
WALTER P MOORE107/09/2025
GEA CONSULTING ENGINEERS610/03/2023
DAHN & KRIEGER ARCHITECTS PLANNERS209/27/2023
KZ ENGINEERING, P.C203/13/2019
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
UNITED SAFETY CONSULTANTS403/21/2026
SYNERGY BUILDING CONSULTANTS203/21/2026
RIZZO GROUP903/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SPRING SCAFFOLDING LLCGeneral Contractor1008/26/2026
EDMONDS CONTRACTING INCGeneral Contractor403/21/2026
CEPRINE CONSTRUCTION INCGeneral Contractor407/08/2026
KALAM CORPGeneral Contractor307/08/2026
HEMNAUTH, SUDESHElectrical103/21/2026
HUDSON PLMBING & MCH, LLCPlumbing107/08/2026
JOSEPH SORTINOElectrical103/21/2026
WALTON, MARCElectrical103/21/2026
FIVE BOROUGH NYC LLCFire Protection107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
WPM NY ENGINEERS INC8597107/09/2025
CODEGREEN510610/03/2023
Building Lifecycle
All (99)Filed (16)Permit Issued (17)Signed Off (6)Violation (31)Inspection (12)Special Inspection (17)
08/12/2026
Permit issued — Sidewalk Shed
M01175465-S2-SH
06/09/2026
Permit issued — Sidewalk Shed
M01175465-S2-SH
04/17/2026
Filed — Alteration
INSTALLATION OF TEMPORARY SIDEWALK SHED AS PER PLAN. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M01175465-P1
04/10/2026
Permit issued — Supported Scaffold
M01193819-I1-SF
03/20/2026
Signed off — Alteration
INSTALLATION OF TEMPORARY SIDEWALK SHED AS PER PLAN. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M01175465-I1
03/19/2026
Permit issued — General Construction
M00912616-I1-GC
03/11/2026
Filed — Alteration
INSTALLATION OF TEMPORARY SIDEWALK SHED AS PER PLAN. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M01175465-S2
03/11/2026
Permit issued — Sidewalk Shed
M01175465-S2-SH
02/12/2026
Permit issued — Sidewalk Shed
M01175465-I1-SH
02/06/2026
Permit issued — General Construction
M00912616-I1-GC
07/22/2025
Permit issued — General Construction
M00912616-I1-GC
07/09/2025
Filed — Alteration
General construction modifications taking place on the facade as per drawings filed herewith. No change in use, egress or occupancy.
M00912616-I1
04/10/2025
Filed — Alteration
INSTALLATION OF TEMPORARY PIPE SCAFFOLD AS PER PLAN. NO CHANGE IN USE, EGRESS OR OCCUPANCY. THE PIPE SCAFFOLD ON BROADWAY AND 5TH AVENUE ELEVATION FROM THE TOP OF THE SIDEWALK SHED PAST THE MAIN ROOF PARAPET WALL.
M01193819-I1
04/10/2025
Permit issued — Supported Scaffold
M01193819-I1-SF
03/27/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Christopher Pinto
03/27/2025
Special inspection requirement — Post-installed Anchors
Christopher Pinto
02/11/2025
Filed — Alteration
INSTALLATION OF TEMPORARY SIDEWALK SHED AS PER PLAN. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M01175465-I1
02/11/2025
Filed — Alteration
INSTALLATION OF TEMPORARY SIDEWALK SHED AS PER PLAN. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M01175465-S1
02/11/2025
Permit issued — Sidewalk Shed
M01175465-I1-SH
02/11/2025
Permit issued — Supported Scaffold
M01175465-S1-SF
01/14/2025
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
09/23/2024
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/17/2024
Signed off — Alteration
MECHANICAL MODIFICATIONS TAKING PLACE ON THE 3RD AND 4TH FLOOR AND ROOF AS PER DRAWINGS FILED HEREWITH. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00785381-I1
05/06/2024
Violation issued (FDNY_NOV, closed)
03/01/2024
Signed off — Alteration
PLUMBING MODIFICATIONS TAKING PLACE IN THE BASEMENT, AND FLOORS 3 AND 4 AS PER DRAWINGS FILED HEREWITH. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00785375-I1
02/14/2024
Signed off — Alteration
GENERAL CONSTRUCTION MODIFICATIONS TAKING PLACE IN THE BASEMENT, FIRST FLOOR, SECOND FLOOR, SECOND FLOOR MEZZANINE, THIRD, FOURTH FLOOR AND ROOF AS PER DRAWINGS FILED HEREWITH. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00785078-I1
02/07/2024
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
01/29/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
01/02/2024
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
11/30/2023
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
11/21/2023
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
10/05/2023
Special inspection requirement — Mechanical Systems
HATIM ELSAID
10/05/2023
Special inspection requirement — Final
HATIM ELSAID
10/03/2023
Filed — Alteration
PLUMBING MODIFICATIONS TAKING PLACE IN THE BASEMENT, AND FLOORS 3 AND 4 AS PER DRAWINGS FILED HEREWITH. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00785375-P1
10/03/2023
Filed — Alteration
MECHANICAL MODIFICATIONS TAKING PLACE ON THE 3RD AND 4TH FLOOR AND ROOF AS PER DRAWINGS FILED HEREWITH. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00785381-P1
10/03/2023
Filed — Alteration
SPRINKLER MODIFICATIONS TAKING PLACE IN THE BASEMENT AND ON THE 3RD AND 4TH FLOOR AS PER DRAWINGS FILED HEREWITH. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00785384-P1
10/03/2023
Special inspection requirement — Sprinkler Systems
HATIM ELSAID
09/29/2023
Special inspection requirement — Preliminary
HATIM ELSAID
09/29/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
HATIM ELSAID
09/29/2023
Special inspection requirement — Final
HATIM ELSAID
09/27/2023
Filed — Alteration
GENERAL CONSTRUCTION MODIFICATIONS TAKING PLACE IN THE BASEMENT, FIRST FLOOR, SECOND FLOOR, SECOND FLOOR MEZZANINE, THIRD, FOURTH FLOOR AND ROOF AS PER DRAWINGS FILED HEREWITH. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00785078-P1
08/30/2023
Violation issued (FDNY_NOV, closed)
08/10/2023
Special inspection requirement — Final
HATIM ELSAID
08/10/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
HATIM ELSAID
08/10/2023
Special inspection requirement — Final
HATIM ELSAID
08/10/2023
Special inspection requirement — Preliminary
HATIM ELSAID
08/10/2023
Special inspection requirement — Mechanical Systems
HATIM ELSAID
08/10/2023
Special inspection requirement — Sprinkler Systems
HATIM ELSAID
08/01/2023
Special inspection requirement — Final
Christopher Pinto
05/19/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
05/03/2023
Inspection — Certified Sprinkler (PL)-SP-Fixtures (PL)-Finish
Certified
View inspection ↗
04/21/2023
Inspection — Certified Sprinkler (PL)-Sprinkler-Hydro
Certified
View inspection ↗
04/20/2023
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
04/20/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
03/14/2023
Permit issued — Mechanical Systems
M00785381-I1-MS
03/14/2023
Permit issued — General Construction
M00785078-I1-GC
03/13/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
02/21/2023
Permit issued — Plumbing
M00785375-I1-PL
02/09/2023
Permit issued — Sprinklers
M00785384-I1-EW-SP
09/28/2022
Filed — Alteration
MECHANICAL MODIFICATIONS TAKING PLACE ON THE 3RD AND 4TH FLOOR AND ROOF AS PER DRAWINGS FILED HEREWITH. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00785381-I1
Latest 60 of 99 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSidewalk ShedPermit IssuedSPRING SCAFFOLDING LLC08/12/2026
DOB NOWSidewalk ShedPermit IssuedSPRING SCAFFOLDING LLC06/09/2026
DOB NOWSupported ScaffoldPermit IssuedSPRING SCAFFOLDING LLC04/10/2026
DOB NOWGeneral ConstructionPermit IssuedKALAM CORP03/19/2026
DOB NOWSidewalk ShedPermit IssuedSPRING SCAFFOLDING LLC03/11/2026
DOB NOWSidewalk ShedSigned-offSPRING SCAFFOLDING LLC02/12/2026
DOB NOWGeneral ConstructionPermit IssuedKALAM CORP02/06/2026
DOB NOWGeneral ConstructionPermit IssuedKALAM CORP07/22/2025
DOB NOWSupported ScaffoldPermit IssuedSPRING SCAFFOLDING LLC04/10/2025
DOB NOWSidewalk ShedSigned-offSPRING SCAFFOLDING LLC02/11/2025
DOB NOWSupported ScaffoldPermit IssuedSPRING SCAFFOLDING LLC02/11/2025
DOB NOWMechanical SystemsSigned-offEDMONDS CONTRACTING03/14/2023
DOB NOWGeneral ConstructionSigned-offEDMONDS CONTRACTING03/14/2023
DOB NOWPlumbingSigned-offHUDSON PLMBING & MCH, LLC02/21/2023
DOB NOWSprinklersPermit IssuedFIVE BOROUGH NYC LLC02/09/2023
DOB NOWSupported ScaffoldSigned-offCEPRINE CONSTRUCTION INC03/14/2019
DOB NOWSidewalk ShedSigned-offCEPRINE CONSTRUCTION INC03/04/2019
BISOTISSUEDWESTERN WATERPROOFING COM11/12/2019
BISMHISSUEDM. LAPENNA REFRIGERATION03/19/2015
BISMHISSUEDM. LAPENNA REFRIGERATION01/28/2009
BISMHISSUEDM. LAPENNA REFRIGERATION01/22/2003
BISMHISSUEDM. LAPENNA REFRIGERATION04/10/2000
BISPLISSUEDBAY RIDGE MECHANICAL CORP08/06/1997
BISPLISSUEDHADERA PLUMBING & HEATING CORP.07/28/1995
BIS—ISSUEDBRONX STORE EQUIPMENT CO., INC.03/10/1995
BISOTISSUEDBX STORE EQUIPTMENT CO INCC01/30/1995
BISMHISSUEDRONORA REALTY CORP11/16/1993
BISOTISSUEDRONORA REALTY CORP.08/13/1993
BIS—ISSUEDRONORA REALTY CORP08/06/1993
1 project · most recent 10/03/2023
FiledStatusContractorScope
10/03/2023Permit IssuedFIVE BOROUGH NYC LLC224 heads
1 project · most recent 10/03/2023
FiledStatusContractorScope
10/03/2023———
5 projects · most recent 02/03/2025
General Wiring
FiledStatusContractorScope
02/03/2025Permit IssuedTOP SHELF ELECTRIC CORP—
09/11/2023Permit IssuedCONDUCTOR ELECL SVCS INC1 meters, 1 new_meters
09/11/2023Permit IssuedCONDUCTOR ELECL SVCS INCGeneral Wiring
01/30/2023Permit IssuedCONDUCTOR ELECL SVCS INC—
02/28/2019CompleteV. VASS ELECTRIC CORP—
2 projects · most recent 04/17/2026
Scaffold Sidewalk Shed
FiledStatusContractorScope
04/17/2026Permit IssuedSPRING SCAFFOLDING LLCScaffold, Sidewalk Shed
04/10/2025Permit IssuedSPRING SCAFFOLDING LLCScaffold
▾Field Inspections (DOB CAP) — 12
DateTypeResultReport
01/14/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
02/07/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
01/29/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
01/02/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
11/30/2023Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
11/21/2023Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
05/19/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
05/03/2023Certified Sprinkler (PL)-SP-Fixtures (PL)-FinishCertifiedView ↗
04/21/2023Certified Sprinkler (PL)-Sprinkler-HydroCertifiedView ↗
04/20/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
04/20/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
03/13/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 17
DateRequirementInspectorRole
03/27/2025Structural Stability – Alterations of existing buildingsChristopher Pintospecial
03/27/2025Post-installed AnchorsChristopher Pintospecial
10/05/2023Mechanical SystemsHATIM ELSAIDspecial
10/05/2023FinalHATIM ELSAIDprogress
10/03/2023Sprinkler SystemsHATIM ELSAIDspecial
09/29/2023PreliminaryHATIM ELSAIDprogress
09/29/2023Fire-Resistant Penetrations and JointsHATIM ELSAIDspecial
09/29/2023FinalHATIM ELSAIDprogress
08/10/2023FinalHATIM ELSAIDprogress
08/10/2023Fire-Resistant Penetrations and JointsHATIM ELSAIDspecial
08/10/2023FinalHATIM ELSAIDprogress
08/10/2023PreliminaryHATIM ELSAIDprogress
08/10/2023Mechanical SystemsHATIM ELSAIDspecial
08/10/2023Sprinkler SystemsHATIM ELSAIDspecial
08/01/2023FinalChristopher Pintoprogress
03/01/2019FinalKarol Zdancewiczprogress
02/28/2019FinalKarol Zdancewiczprogress
▾Documents — 149 on file (BIS + DOB NOW)
▸Plans & Drawings16
▸DOB NOWPlans/Sketch14
09/01/2026M00785078-I1Request digital key ↗
09/01/2026M00785078-P1Request digital key ↗
09/01/2026M00785375-P1Request digital key ↗
Showing 3 of 14 on file for this type
▸DOB NOWPlans/Sketch - Sidewalk Shed1
09/05/2026M00136573-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Supported Scaffold1
09/05/2026M00136976-I1Request digital key ↗
▸Applications & Permits24
▸BISPLAN / WORK APPROVAL APPLICATION14
11/13/2019123739623Open ↗
05/31/2019140850363Open ↗
04/22/2019121189105Open ↗
Showing 3 of 14 on file for this type
▸DOB NOWLPC Approval/Permit7
08/13/2026M00785078-P1Open ↗
08/13/2026M00785375-I1Open ↗
08/13/2026M00785375-P1Open ↗
Showing 3 of 7 on file for this type
▸BISWORK PERMIT APPLICATION3
11/12/2019123739623Open ↗
03/19/2015140271220Open ↗
01/28/2009110370027Open ↗
▸Seals & Professional Certifications44
▸DOB NOWDPL-1: Design Professional Seal & Signature17
09/01/2026M00785078-P1Open ↗
09/01/2026M00785078-I1Open ↗
09/01/2026M00785375-P1Open ↗
Showing 3 of 17 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature8
08/26/2026M00912616-I1Open ↗
08/26/2026M00912616-I1Open ↗
08/22/2026M00785078-I1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWProgress Inspector Seal & Signature7
08/26/2026M00912616-I1Open ↗
08/25/2026M00136573-I1Open ↗
08/24/2026M00136976-I1Open ↗
Showing 3 of 7 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION4
11/13/2019123739623Open ↗
05/15/2015140271220Open ↗
02/13/2009110370027Open ↗
Showing 3 of 4 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT3
11/13/2019123739623Open ↗
05/31/2019140850363Open ↗
12/19/2014140271220Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION2
05/31/2019140850363Open ↗
12/19/2014140271220Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY2
05/31/2019140850363Open ↗
12/19/2014140271220Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
11/13/2019123739623Open ↗
▸Trade Schedules & Equipment9
▸BISEQUIPMENT USE PERMITS4
05/15/2015140271220Open ↗
05/15/2015140271220Open ↗
05/15/2015140271220Open ↗
Showing 3 of 4 on file for this type
▸BISEQUIPMENT USE APPLICATION/PERMIT3
05/15/2015140271220Open ↗
04/27/2015140271220Open ↗
02/13/2009110370027Open ↗
▸BISSCHEDULE B - PLUMBING2
11/26/2018121189105Open ↗
11/26/2018121189105Open ↗
▸Safety & Tenant Protection1
▸BISSTREET TREE CHECKLIST1
02/07/2019121189105Open ↗
▸Environmental & Asbestos8
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form4
09/01/2026M00785078-I1Open ↗
09/01/2026M00785375-I1Open ↗
09/01/2026M00785384-I1Open ↗
Showing 3 of 4 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)2
11/12/2019123739623Open ↗
12/19/2014140271220Open ↗
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/13/2026M00136976-I1Open ↗
08/13/2026M00912616-I1Open ↗
▸Energy Compliance3
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
05/15/2015140271220Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
12/19/2014140271220Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
12/19/2014140271220Open ↗
▸Inspections & Test Reports4
▸BISTECHNICAL REPORT: RESPONSIBILITY4
12/07/2018121189105Open ↗
11/28/2018121189105Open ↗
11/28/2018121189105Open ↗
Showing 3 of 4 on file for this type
▸Approvals, Objections & Sign-offs13
▸BISLANDMARKS APPROVAL5
11/13/2019123739623Open ↗
11/13/2019123739623Open ↗
05/31/2019140850363Open ↗
Showing 3 of 5 on file for this type
▸BISSCHEDULE A - OCCUPANCY / USE4
03/07/2019121189105Open ↗
02/07/2019121189105Open ↗
01/22/2019121189105Open ↗
Showing 3 of 4 on file for this type
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST2
05/15/2015140271220Open ↗
02/13/2009110370027Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
02/13/2009110370027Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
10/21/2008110370027Open ↗
▸Cost, Insurance & Ownership7
▸BISCOST AFFIDAVIT7
11/13/2019123739623Open ↗
05/31/2019140850363Open ↗
05/15/2015140271220Open ↗
Showing 3 of 7 on file for this type
▸Filing & Intake Forms13
▸BISEFILING COVER SHEET10
11/13/2019123739623Open ↗
04/22/2019121189105Open ↗
04/18/2019121189105Open ↗
Showing 3 of 10 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET2
05/31/2019140850363Open ↗
12/19/2014140271220Open ↗
▸BISADDITIONAL INFORMATION1
04/10/2015140271220Open ↗
▸Other Documents7
▸DOB NOWProof of Historic Building7
08/13/2026M00785078-I1Open ↗
08/13/2026M00785078-P1Open ↗
08/13/2026M00785375-I1Open ↗
Showing 3 of 7 on file for this type