← Back
Two family converted from one family
2042 81 STREET
BROOKLYN · Bensonhurst · BIN 3401918
💬 Discuss this project
1920Year Built
2Stories
B3Building Class
R5Zoning
2,270 sfGross Floor Area
2Units
0 Open ViolationsFDNY Report ↗
Two family converted from one family · Owner of record: HONG FU 18 INC. · 4,000 sf lot · 0.57 FAR built · Flood zone X
Locations of Work
Architecture
Permit Issued — active, not yet Signed-off
RoofUnder Construction1p · 1 filing · 10 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
HONG FU 18 INC.303/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
10/25/2022$1.7M—Private party → HONG FU 18 INC.$762/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NY BUILDING ASSOCIATES INC303/02/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
HIGHQUALITY CONSTRUCTION VNW503/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
HIGH QUALITY CONSTRUCTIONGeneral Contractor104/10/2026
AMERICAN STANDARD P&H CORORP.Plumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NKM ENGINEERING PLLC6244203/02/2026
Building Lifecycle
All (43)Filed (3)Permit Issued (2)Signed Off (2)Violation (3)Inspection (1)Objection (21)Special Inspection (11)
07/20/2026
Signed off — Alteration
B01327940-I1
07/20/2026
Signed off — Alteration
B01327940-S1
05/29/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
04/08/2026
Permit issued — General Construction
B01327940-I1-GC-CX
04/08/2026
Permit issued — Plumbing
B01327940-S1-PL
03/03/2026
Objection raised — Plumbing
03/03/2026
Objection resolved — Addressed
03/03/2026
Objection raised — Plumbing
03/03/2026
Objection resolved — Addressed
03/02/2026
Filed — Alteration
B01327940-S1
02/03/2026
Objection resolved — Addressed
01/14/2026
Objection raised — Cost
12/29/2025
Objection resolved — Addressed
12/24/2025
Objection raised — Scope
12/08/2025
Objection resolved — Addressed
12/08/2025
Objection resolved — Addressed
12/08/2025
Objection resolved — Addressed
12/08/2025
Objection resolved — Addressed
12/08/2025
Special inspection requirement — Electric vehicle service equipment requirements
NARESH MAHANGU
12/04/2025
Objection raised — Zoning
12/04/2025
Objection raised — Energy
12/04/2025
Objection raised — Zoning
12/04/2025
Objection raised — Zoning
12/03/2025
Filed — Alteration
B01327940-I1
12/03/2025
Special inspection requirement — Concrete - Cast-In-Place
12/03/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
12/03/2025
Special inspection requirement — Fire-Resistance Rated Construction
12/03/2025
Special inspection requirement — Masonry
NARESH MAHANGU
12/03/2025
Special inspection requirement — Fire-Resistance Rated Construction
NARESH MAHANGU
12/03/2025
Special inspection requirement — Final
Chun Feng
12/03/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
NARESH MAHANGU
12/03/2025
Special inspection requirement — Concrete - Cast-In-Place
NARESH MAHANGU
09/02/2025
Objection raised — Cost
09/02/2025
Objection raised — Scope
09/02/2025
Objection raised — Scope
09/02/2025
Objection raised — Scope
09/02/2025
Objection raised — Scope
08/20/2025
Filed — Alteration
B01272622-I1
08/20/2025
Special inspection requirement — Masonry
08/15/2025
Special inspection requirement — Final
08/14/2025
Violation issued (ECB, closed)
Construction
08/14/2025
Violation issued (ECB, closed)
Unknown
08/14/2025
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offHIGH QUALITY CONSTRUCTION04/08/2026
DOB NOWPlumbingPermit IssuedAMERICAN STANDARD P&H CORORP.04/08/2026
1 project · most recent 04/07/2026
General Wiring
FiledStatusContractorScope
04/07/2026Permit IssuedJ Y ELECTRIC INCGeneral Wiring
2 projects · most recent 03/02/2026
Masonry Wood
FiledStatusContractorScope
03/02/2026Signed-offHIGH QUALITY CONSTRUCTIONMasonry, Wood
08/20/2025——Masonry, Wood
▾Field Inspections (DOB CAP) — 1
DateTypeResultReport
05/29/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 11
DateRequirementInspectorRole
12/08/2025Electric vehicle service equipment requirementsNARESH MAHANGUenergy_progress
12/03/2025Concrete - Cast-In-Place—special
12/03/2025Fire-Resistant Penetrations and Joints—special
12/03/2025Fire-Resistance Rated Construction—progress
12/03/2025MasonryNARESH MAHANGUspecial
12/03/2025Fire-Resistance Rated ConstructionNARESH MAHANGUprogress
12/03/2025FinalChun Fengprogress
12/03/2025Fire-Resistant Penetrations and JointsNARESH MAHANGUspecial
12/03/2025Concrete - Cast-In-PlaceNARESH MAHANGUspecial
08/20/2025Masonry—special
08/15/2025Final—progress
▾Documents — 13 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/18/2026B01327940-I1Request digital key ↗
08/18/2026B01327940-S1Request digital key ↗
08/15/2026B01272622-I1Request digital key ↗
▸Seals & Professional Certifications7
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/18/2026B01327940-I1Open ↗
08/18/2026B01327940-S1Open ↗
08/13/2026B01272622-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature3
08/28/2026B01327940-I1Open ↗
08/28/2026B01327940-I1Open ↗
08/28/2026B01327940-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/28/2026B01327940-I1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/18/2026B01327940-S1Open ↗
08/18/2026B01327940-I1Open ↗
08/13/2026B01272622-I1Open ↗