← Back
Two family brick
2048 RYER AVENUE
BRONX · BIN 2013497
💬 Discuss this project
1901Year Built
2Stories
B1Building Class
R7-1Zoning
2,360 sfGross Floor Area
2Units
Rent Stabilized0 Open Violations
Two family brick · Owner of record: 2048 RYER LLC · 2,469 sf lot · 0.96 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbingFire Protection
Floor 218p · 1 filing · 20 docs
Floor 115p · 1 filing · 20 docs
Cellar19p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
2048 RYER LLC203/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
09/26/2024$1.1M—— → —$477/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NIKOLAI KATZ ARCHITECT407/07/2026
CHUN ENGINEERING CONSULTANT PLLC101/29/2026
VASILIOS ARTEMIOU PE603/07/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
EXPRESS FILING INC2003/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
BUILDERS GROUP USA INCGeneral Contractor304/09/2026
FRIED ELECTRIC CO.Electrical203/22/2026
PRIME PIPING & HEATING INFire Protection107/08/2026
PRIME PIPING & HEATING INPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
HRF SERVICES CORP56161007/07/2026
NKM ENGINEERING PLLC6244101/29/2026
Building Lifecycle
All (88)Filed (11)Permit Issued (5)Signed Off (4)Violation (4)Inspection (8)Objection (26)Special Inspection (30)
07/07/2026
Filed — Alteration CO
MECHANICAL SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION # X01069071-I1
X01069071-P7
07/02/2026
Special inspection requirement — Interior lighting power
FAHAD FATEH
07/02/2026
Special inspection requirement — Permanent certificate
FAHAD FATEH
07/02/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
FAHAD FATEH
07/02/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
FAHAD FATEH
07/02/2026
Special inspection requirement — Energy Code Compliance Inspections
FAHAD FATEH
07/02/2026
Special inspection requirement — Maintenance information
FAHAD FATEH
07/02/2026
Special inspection requirement — Fenestration areas
FAHAD FATEH
07/02/2026
Special inspection requirement — Metering
FAHAD FATEH
07/02/2026
Special inspection requirement — Insulation placement and R values
FAHAD FATEH
07/02/2026
Special inspection requirement — Fenestration air leakage
FAHAD FATEH
07/02/2026
Special inspection requirement — Fire-Resistance Rated Construction
FAHAD FATEH
04/21/2026
Signed off — Alteration CO
MECHANICAL SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION # X01069071-I1
X01069071-S4
03/20/2026
Permit issued — Structural
X01069071-S4-ST
02/24/2026
Objection resolved — Addressed
02/24/2026
Objection resolved — Addressed
02/24/2026
Objection resolved — Addressed
02/09/2026
Objection raised — Structural
02/09/2026
Objection raised — Structural
02/09/2026
Objection raised — Structural
01/29/2026
Filed — Alteration CO
MECHANICAL SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION # X01069071-I1
X01069071-S4
01/28/2026
Signed off — Alteration CO
MECHANICAL SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION # X01069071-I1
X01069071-S3
01/28/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
NARESH MAHANGU
01/28/2026
Special inspection requirement — Raising and Moving of a Building
NARESH MAHANGU
01/28/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
NARESH MAHANGU
01/28/2026
Special inspection requirement — Final
Lester Katz
01/11/2026
Violation issued (HPD, closed)
C
01/11/2026
Violation issued (HPD, closed)
C
09/15/2025
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
06/05/2025
Violation issued (HPD, closed)
A
04/24/2025
Filed — Alteration CO
MECHANICAL SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION # X01069071-I1
X01069071-P6
04/09/2025
Special inspection requirement — Maintenance information
FAHAD FATEH
04/09/2025
Special inspection requirement — Energy Code Compliance Inspections
FAHAD FATEH
04/09/2025
Special inspection requirement — Fire-Resistance Rated Construction
FAHAD FATEH
04/09/2025
Special inspection requirement — Permanent certificate
FAHAD FATEH
04/09/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
FAHAD FATEH
04/09/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
FAHAD FATEH
04/09/2025
Special inspection requirement — Interior lighting power
FAHAD FATEH
04/09/2025
Special inspection requirement — Fenestration areas
FAHAD FATEH
04/09/2025
Special inspection requirement — Metering
FAHAD FATEH
04/09/2025
Special inspection requirement — Fenestration air leakage
FAHAD FATEH
04/09/2025
Special inspection requirement — Insulation placement and R values
FAHAD FATEH
03/20/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
03/18/2025
Signed off — Alteration CO
MECHANICAL SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION # X01069071-I1
X01069071-S1
03/18/2025
Special inspection requirement — Post-installed Anchors
FAHAD FATEH
03/18/2025
Special inspection requirement — Ventilation and air distribution system
FAHAD FATEH
03/18/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
FAHAD FATEH
03/18/2025
Special inspection requirement — Mechanical Systems
FAHAD FATEH
03/17/2025
Signed off — Alteration CO
MECHANICAL SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION # X01069071-I1
X01069071-S2
03/11/2025
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
03/07/2025
Filed — Alteration CO
MECHANICAL SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION # X01069071-I1
X01069071-P5
03/05/2025
Filed — Alteration CO
MECHANICAL SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION # X01069071-I1
X01069071-P3
03/05/2025
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
02/17/2025
Objection resolved — Addressed
02/13/2025
Objection raised — Other
02/11/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
02/06/2025
Filed — Alteration CO
MECHANICAL SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION # X01069071-I1
X01069071-P4
01/20/2025
Filed — Alteration CO
MECHANICAL SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION # X01069071-I1
X01069071-P2
12/24/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
12/16/2024
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
Latest 60 of 88 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralSigned-offBUILDERS GROUP USA03/20/2026
DOB NOWGeneral ConstructionPermit IssuedBUILDERS GROUP USA11/26/2024
DOB NOWMechanical SystemsSigned-offBUILDERS GROUP USA11/21/2024
DOB NOWPlumbingSigned-offPRIME PIPING & HEATING IN11/15/2024
DOB NOWSprinklersSigned-offA M B MECHANICAL INC11/14/2024
1 project · most recent 07/07/2026
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
07/07/2026Signed-offBUILDERS GROUP USA INCHeating and Air Conditioning Systems
Heat / Cool
Daikin 2MXM18AVJU9 18,500 BTU · Condensing Unit ×6
RXF18AXVJU 21,600 BTU · Heat Pump Outdoor ×4
1 project · most recent 07/07/2026
Sprinkler System
FiledStatusContractorScope
07/07/2026Signed-offPRIME PIPING & HEATING INSprinkler System
1 project · most recent 07/07/2026
Gas Storm Water/Sanitary
FiledStatusContractorScope
07/07/2026Signed-offA M B MECHANICAL INCGas, Storm, Water/Sanitary
2 projects · most recent 11/20/2025
General Wiring
FiledStatusContractorScope
11/20/2025CompleteFRIED ELECTRIC CO.General Wiring
12/02/2024CompleteFRIED ELECTRIC CO.General Wiring
1 project · most recent 07/07/2026
Wood
FiledStatusContractorScope
07/07/2026Signed-offBUILDERS GROUP USA INCWood
▾Field Inspections (DOB CAP) — 8
DateTypeResultReport
09/15/2025Fail-Final General Construction Non-Directive 14FailView ↗
03/20/2025Pass-Final CND-Occupancy InspectionPassView ↗
03/11/2025Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
03/05/2025Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
02/11/2025Pass-Final CND-Occupancy InspectionPassView ↗
12/24/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
12/16/2024Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
12/16/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 72
DateRequirementInspectorRole
07/02/2026Insulation placement and R valuesFAHAD FATEHenergy_progress
07/02/2026Maintenance informationFAHAD FATEHenergy_progress
07/02/2026Fenestration and door U-factor and product ratingsFAHAD FATEHenergy_progress
07/02/2026Interior lighting powerFAHAD FATEHenergy_progress
07/02/2026Permanent certificateFAHAD FATEHenergy_progress
07/02/2026MeteringFAHAD FATEHenergy_progress
07/02/2026Fenestration air leakageFAHAD FATEHenergy_progress
07/02/2026Fenestration areasFAHAD FATEHenergy_progress
07/02/2026Fire-Resistance Rated ConstructionFAHAD FATEHprogress
07/02/2026Energy Code Compliance InspectionsFAHAD FATEHprogress
07/02/2026Fire-Resistant Penetrations and JointsFAHAD FATEHspecial
01/28/2026Raising and Moving of a BuildingNARESH MAHANGUspecial
01/28/2026Fire-Resistant Penetrations and JointsNARESH MAHANGUspecial
01/28/2026FinalLester Katzprogress
01/28/2026Structural Stability – Alterations of existing buildingsNARESH MAHANGUspecial
04/09/2025Fenestration areasFAHAD FATEHenergy_progress
04/09/2025Fenestration air leakageFAHAD FATEHenergy_progress
04/09/2025MeteringFAHAD FATEHenergy_progress
04/09/2025Permanent certificateFAHAD FATEHenergy_progress
04/09/2025Fire-Resistance Rated ConstructionFAHAD FATEHprogress
04/09/2025Energy Code Compliance InspectionsFAHAD FATEHprogress
04/09/2025Fire-Resistant Penetrations and JointsFAHAD FATEHspecial
04/09/2025Maintenance informationFAHAD FATEHenergy_progress
04/09/2025Fenestration and door U-factor and product ratingsFAHAD FATEHenergy_progress
04/09/2025Insulation placement and R valuesFAHAD FATEHenergy_progress
Latest 25 of 72.
▾Documents — 70 on file (BIS + DOB NOW)
▸Plans & Drawings11
▸DOB NOWPlans/Sketch11
08/21/2026X01069071-S4Request digital key ↗
08/21/2026X01069071-P6Request digital key ↗
08/21/2026X01069071-P5Request digital key ↗
Showing 3 of 11 on file for this type
▸Seals & Professional Certifications35
▸DOB NOWProgress Inspector Seal & Signature15
09/01/2026X01069071-S4Open ↗
08/30/2026X01069071-P4Open ↗
08/30/2026X01069071-P4Open ↗
Showing 3 of 15 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature11
08/21/2026X01069071-P6Open ↗
08/21/2026X01069071-P5Open ↗
08/21/2026X01069071-P4Open ↗
Showing 3 of 11 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature9
09/01/2026X01069071-S4Open ↗
08/30/2026X01069071-P4Open ↗
08/29/2026X01069071-S1Open ↗
Showing 3 of 9 on file for this type
▸Safety & Tenant Protection7
▸DOB NOWStreet Tree Checklist4
08/21/2026X01069071-P7Open ↗
08/13/2026X01069071-P6Open ↗
08/13/2026X01069071-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWStreet Trees Site Plan1
08/13/2026X01069071-I1Open ↗
▸DOB NOWStreet Tree Sign Off1
08/13/2026X01069071-I1Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026X01069071-I1Open ↗
▸Environmental & Asbestos12
▸DOB NOWDEP ACP-5: Asbestos Assessment Report11
08/21/2026X01069071-P6Open ↗
08/21/2026X01069071-P5Open ↗
08/21/2026X01069071-P3Open ↗
Showing 3 of 11 on file for this type
▸DOB NOWACP5/20/21 or V51
08/21/2026X01069071-S2Open ↗
▸Other Documents5
▸DOB NOWProperty Ownership Certification4
08/21/2026X01069071-P6Open ↗
08/21/2026X01069071-I1Open ↗
08/21/2026X01069071-P7Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWFinal Survey1
08/13/2026X01069071-I1Open ↗