← Back
BuildNYC
Three families
205 BAY 25 STREET
BROOKLYN · Bath Beach · BIN 3168838
💬 Discuss this project
1920Year Built
2.75Stories
C0Building Class
R5Zoning
3,593 sfGross Floor Area
3Units
Rent Stabilized0 Active ViolationsFDNY Report ↗
Three families · 3,383 sf lot · 1.06 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbingFire Protection
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Permit Issued — active, not yet Signed-off
Attic2p · 1 filing · 10 docs
Floor 3Renovate cellar, 1st, 2nd, 3rd floors: new partition, cosmetUnder Construction1p · 1 filing · 16 docs
Floor 2Renovate cellar, 1st, 2nd, 3rd floors: new partition, cosmetUnder Construction3p · 2 filings · 20 docs
Floor 1Renovate cellar, 1st, 2nd, 3rd floors: new partition, cosmetUnder Construction7p · 2 filings · 20 docs
CellarRenovate cellar, 1st, 2nd, 3rd floors: new partition, cosmetUnder Construction4p · 2 filings · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
11/03/2021$1.4M—Private party → Private party$390/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
HPL Engineering607/30/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
JM Consultant Studio803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
High Quality ConstructionGeneral Contractor104/09/2026
Mercury Building AssociatesGeneral Contractor107/08/2026
American Standard P&H CororpPlumbing107/08/2026
VMC Plumbing & HeatingPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
HPL Engineering5613408/19/2024
Building Lifecycle
07/30/2026
Filed — Alteration
FILE PLUMBING WORK IN-CONJUNCTION WITH DOBNow GC JOB#: B01073499-I1. REPLACE & INSTALL NEW PLUMBING FIXTURES ON 1ST FL AS PER PLAN SUBMITTED. WITHDRAW BIS JOB# 301910092 BASED ON DOBNow JOB#: B01073499-I1. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
B01073499-P2
05/01/2026
(a) § hmc:file annual bedbug report in accordance with HPD rule as described on the back of this notice of violation or as described on HPDs…
HPD violation · closed
04/30/2026
Filed — Alteration
FILE PLUMBING WORK IN-CONJUNCTION WITH DOBNow GC JOB#: B01073499-I1. REPLACE & INSTALL NEW PLUMBING FIXTURES ON 1ST FL AS PER PLAN SUBMITTED. WITHDRAW BIS JOB# 301910092 BASED ON DOBNow JOB#: B01073499-I1. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
B01073499-P1
04/28/2026
Permit renewed — General Construction
Renewed with changes
B01073499-I1-GC
04/28/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
51 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedMercury Building Associates04/28/2026
DOB NOWPlumbingPermit IssuedAmerican Standard P&H Cororp03/13/2026
DOB NOWGeneral ConstructionPermit IssuedHigh Quality Construction03/04/2026
DOB NOWPlumbingSigned-offM. Spinelli PLB & Heating04/20/2022
1 project · most recent 07/30/2026
Gas Water/Sanitary
FiledStatusContractorScope
07/30/2026Permit IssuedAmerican Standard P&HGas, Water/Sanitary
1 project · most recent 09/29/2022
FiledStatusContractorScope
09/29/2022CompleteKJK Electric—
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
04/28/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
09/09/2022Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
09/09/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
07/15/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
05/25/2022Fail-Final PL - Up to 3 Requested FloorsFailView ↗
▾Special Inspection Requirements (DOB NOW) — 6
DateRequirementInspectorRole
07/15/2025Structural Stability – Alterations of existing buildingsFran Huangspecial
08/19/2024Fire-Resistant Penetrations and JointsFran Huangspecial
06/14/2022Fire-Resistant Penetrations and JointsFran Huangspecial
06/14/2022Energy Code Compliance InspectionsFran Huangprogress
06/10/2022Fire-Resistant Penetrations and JointsFran Huangspecial
06/10/2022Energy Code Compliance InspectionsFran Huangprogress
24 filed documents on file for this building. Sign in free to see the full history. Sign in · Create account