← Back
Two stories - detached, small or mid-size
206-09 109 AVENUE
QUEENS · Queens Village · BIN 4233439
💬 Discuss this project
1925Year Built
2.5Stories
A1Building Class
R3-2Zoning
1,710 sfGross Floor Area
1Units
Two stories - detached, small or mid-size · 4,000 sf lot · 0.43 FAR built · Flood zone X
Locations of Work
ArchitectureElectricalGeneral
Roof1 filing · 4 docs
Filed — no permit issued8p · 1 filing · 4 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
MOMENTUM SOLAR103/26/2024
ASKON ARCHITECTS, P.C.101/31/2021
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
MXV SIA LLC9281103/26/2024
ASKON ARCHITECT, P.C.3596101/31/2021
Building Lifecycle
All (19)Filed (2)Permit Issued (1)Objection (2)Special Inspection (14)
04/01/2024
Permit issued — Solar
Q01023102-I1-SL
03/26/2024
Filed — Alteration
Installation of solar panels, rooftop, railed, grid-tied, 13 modules, 13.94 KW
Q01023102-I1
02/25/2021
Objection raised — Zoning
02/25/2021
Objection raised — Other
01/31/2021
Filed — Alteration
FILING FOR HORIZONTAL AND VERTICAL ENLARGEMENT AND CONVERSION FROM ONE FAMILY TO TWO FAMILIES. NEW CERTIFICATE OF OCCUPANCY IS REQUIRED.
Q00459300-I1
01/31/2021
Special inspection requirement — Concrete - Cast-In-Place
Akeeb Shekoni
01/31/2021
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
Akeeb Shekoni
01/31/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
Akeeb Shekoni
01/31/2021
Special inspection requirement — Masonry
Akeeb Shekoni
01/31/2021
Special inspection requirement — Structural Stability – Alterations of existing buildings
Akeeb Shekoni
01/31/2021
Special inspection requirement — HVAC-R and service water piping design and insulation
Akeeb Shekoni
01/31/2021
Special inspection requirement — Fenestration and door U-factor and product ratings
Akeeb Shekoni
01/31/2021
Special inspection requirement — Lighting in dwelling units
Akeeb Shekoni
01/31/2021
Special inspection requirement — Air barrier - visual inspection
Akeeb Shekoni
01/31/2021
Special inspection requirement — Insulation placement and R values
Akeeb Shekoni
01/31/2021
Special inspection requirement — Metering
Akeeb Shekoni
01/31/2021
Special inspection requirement — Fenestration areas
Akeeb Shekoni
01/31/2021
Special inspection requirement — Fenestration air leakage
Akeeb Shekoni
01/31/2021
Special inspection requirement — Protection of exposed foundation insulation
Akeeb Shekoni
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offMOMENTUM SOLAR04/01/2024
1 project · most recent 03/21/2024
FiledStatusContractorScope
03/21/2024CompleteISLAND ELECTRIC CORP—
1 project · most recent 03/26/2024
FiledStatusContractorScope
03/26/2024Signed-offMOMENTUM SOLAR34 panels, 13.94 kw, 598 roof_area_sqft
▾Special Inspection Requirements (DOB NOW) — 14
DateRequirementInspectorRole
01/31/2021Concrete - Cast-In-PlaceAkeeb Shekonispecial
01/31/2021Excavations - Sheeting, Shoring, and BracingAkeeb Shekonispecial
01/31/2021Fire-Resistant Penetrations and JointsAkeeb Shekonispecial
01/31/2021MasonryAkeeb Shekonispecial
01/31/2021Structural Stability – Alterations of existing buildingsAkeeb Shekonispecial
01/31/2021HVAC-R and service water piping design and insulationAkeeb Shekonienergy_progress
01/31/2021Fenestration and door U-factor and product ratingsAkeeb Shekonienergy_progress
01/31/2021Lighting in dwelling unitsAkeeb Shekonienergy_progress
01/31/2021Air barrier - visual inspectionAkeeb Shekonienergy_progress
01/31/2021Insulation placement and R valuesAkeeb Shekonienergy_progress
01/31/2021MeteringAkeeb Shekonienergy_progress
01/31/2021Fenestration areasAkeeb Shekonienergy_progress
01/31/2021Fenestration air leakageAkeeb Shekonienergy_progress
01/31/2021Protection of exposed foundation insulationAkeeb Shekonienergy_progress
▾Documents — 8 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch1
08/23/2026Q01023102-I1Request digital key ↗
▸DOB NOWPlans/Sketch - General Construction1
08/27/2026Q00459300-I1Request digital key ↗
▸Seals & Professional Certifications2
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/23/2026Q01023102-I1Open ↗
08/13/2026Q00459300-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/23/2026Q01023102-I1Open ↗
08/13/2026Q00459300-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026Q01023102-I1Open ↗
▸Other Documents1
▸DOB NOWPlot Diagram1
08/13/2026Q00459300-I1Open ↗