← Back
Elevator apt, miscellaneous
206 WEST 106 STREET
MANHATTAN · Upper West Side-Manhattan Valley · BIN 1056621
💬 Discuss this project
1910Year Built
6Stories
D9Building Class
R8AZoning
31,476 sfGross Floor Area
59Units
LL97 CoveredRent Stabilized4 Open Violations ▸FISP: SAFEFDNY Report ↗
Elevator apt, miscellaneous · Owner of record: 204-206 W. 106TH ST, · 7,575 sf lot · 4.16 FAR built · Flood zone X
Locations of Work
ArchitectureEquipmentGeneral
Site & exterior11p · 2 filings · 13 docs
Filed — no permit issued5p · 1 filing · 7 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
204-206 W 106TH ST1403/22/2026
204-206 2 106TH ST203/21/2026
204-206 WEST 106TH ST103/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ROGER DE ELECTRIC CO.308/21/2024
SYED ENGINEERING, P.C.107/26/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
SALAMON ENGINEERING PLLC403/21/2026
ARSENAL BUILDING CONSULTANTS LLC203/21/2026
AE DESIGN SOLUTION203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
PHOENIX SUTTON STR INCGeneral Contractor507/08/2026
HEMANCHAL DEONARINEElectrical103/21/2026
INTER RENOVATION INCGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SALAMON ENGINEERING PLLC1264208/21/2024
ANS CONSULTANTS, INC.1768106/25/2021
EPSTEIN ENGINEERING, P.C.1213106/25/2021
Building Lifecycle
All (85)Filed (5)Permit Issued (5)Signed Off (2)Facade (FISP) (18)Violation (45)Objection (1)Special Inspection (9)
08/23/2024
Signed off — Alteration
Facade repair
M00888162-I1
08/22/2024
Special inspection requirement — Masonry
David Salamon
08/22/2024
Special inspection requirement — Tenant Protection Plan Compliance
David Salamon
08/22/2024
Special inspection requirement — Final
David Salamon
08/21/2024
Filed — Alteration
Facade repair
M00888162-P1
08/15/2024
Signed off — Alteration
PROPOSED INSTALLATION OF HEAVY DUTY SIDEWALK SHED AS PER PLANS. LIVEL LOAD 300 PER SQUARE FEET. SIDEWALK SHED SHALL COMPLY WITH CHAPTER #33 OF THE 2014 CODE. NO CHANGE IN USE OCCUPANCY OR EGRESS UNDER THIS APPLICATION.
M00561628-I1
07/30/2024
Special inspection requirement — Final
David Salamon
07/30/2024
Special inspection requirement — Tenant Protection Plan Compliance
07/30/2024
Special inspection requirement — Masonry
David Salamon
07/01/2024
Cycle 9 facade report submitted
07/01/2024
Cycle 9 facade inspection completed
07/01/2024
Cycle 9 facade report signed — SAFE
02/12/2024
Permit issued — Sidewalk Shed
M00561628-I1-SH
01/10/2024
Permit issued — Suspended Scaffold
M00976621-I1-SC
12/13/2023
Filed — Alteration
M00976621-I1
07/27/2023
Permit issued — General Construction
M00888162-I1-GC
06/23/2023
Filed — Alteration
Facade repair
M00888162-I1
04/20/2023
Violation issued (HPD, closed)
A
04/20/2023
Violation issued (HPD, closed)
C
04/20/2023
Violation issued (HPD, closed)
C
03/16/2023
Cycle 9 facade report submitted
03/16/2023
Cycle 9 facade inspection completed
02/22/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
02/17/2023
Cycle 9 facade report signed — UNSAFE
02/15/2023
Permit issued — Sidewalk Shed
M00561628-I1-SH
08/25/2022
Violation issued (HPD, closed)
A
08/25/2022
Violation issued (HPD, closed)
C
07/12/2022
Violation issued (HPD, closed)
C
07/12/2022
Violation issued (HPD, closed)
C
07/12/2022
Violation issued (HPD, closed)
C
07/12/2022
Violation issued (HPD, closed)
C
06/02/2022
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/29/2022
Violation issued (HPD, closed)
A
03/29/2022
Violation issued (HPD, closed)
B
03/29/2022
Violation issued (HPD, closed)
C
03/29/2022
Violation issued (HPD, closed)
A
03/29/2022
Violation issued (HPD, closed)
A
03/29/2022
Violation issued (HPD, closed)
B
07/26/2021
Filed — Alteration
PROPOSED INSTALLATION OF HEAVY DUTY SIDEWALK SHED AS PER PLANS. LIVEL LOAD 300 PER SQUARE FEET. SIDEWALK SHED SHALL COMPLY WITH CHAPTER #33 OF THE 2014 CODE. NO CHANGE IN USE OCCUPANCY OR EGRESS UNDER THIS APPLICATION.
M00561628-I1
07/26/2021
Permit issued — Sidewalk Shed
M00561628-I1-SH
07/02/2021
Objection raised — Other
06/25/2021
Filed — Alteration
EXTERIOR REPAIRWORK AS PER PLANS FILED HEREWITH. NO CHANGE TO USE, GROUP, OR OCCUPANCY. PLANS FOR A SIDEWALK SHED ARE BEING FILED SEPARATELY FOR THIS PROJECT.
M00469450-I1
04/21/2021
Special inspection requirement — Structural Stability – Alterations of existing buildings
ATULKUMAR SHAH, PE
03/10/2021
Special inspection requirement — Masonry
ALAN EPSTEIN
02/11/2021
Special inspection requirement — Final
ALAN EPSTEIN
08/24/2020
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
05/14/2018
Cycle 8 facade report signed — SAFE
03/15/2018
Violation issued (ECB, closed)
Construction
02/27/2018
Violation issued (HPD, closed)
C
01/09/2018
Cycle 8 facade report submitted
12/28/2017
Cycle 8 facade inspection completed
12/01/2016
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
11/14/2016
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
07/10/2014
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
08/30/2013
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/22/2013
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
04/16/2013
Cycle 7 facade report signed — SAFE
12/06/2012
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
08/20/2012
Cycle 7 facade report submitted
08/16/2012
Cycle 7 facade inspection completed
Latest 60 of 85 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSidewalk ShedSigned-offPHOENIX SUTTON STR INC02/12/2024
DOB NOWSuspended ScaffoldPermit IssuedINTER RENOVATION INC01/10/2024
DOB NOWGeneral ConstructionSigned-offINTER RENOVATION INC07/27/2023
DOB NOWSidewalk ShedSigned-offPHOENIX SUTTON STR INC02/15/2023
DOB NOWSidewalk ShedSigned-offPHOENIX SUTTON STR INC07/26/2021
BISOTISSUEDCHAMPION COMBUSTION CORP05/29/2018
BISPLISSUEDCHAMP PLUMBING & HTG CORP05/29/2018
BISOTISSUEDINTRAKO INC06/20/2017
BISOTISSUEDINTRAKO INC03/29/2017
BISEQISSUEDBILLY ENTERPRISES INC11/07/2016
BISOTISSUEDA W R GROUP INC05/22/2012
BISOTISSUEDA W R GROUP INC03/06/2012
BISOTISSUEDA W R GROUP INC01/26/2012
BISEQISSUEDEVEREST SCAFFOLDING INC01/23/2012
BISOTISSUEDJADE RESTORATION CORP11/02/2009
BISOTISSUEDA SAAD CONTRACTING INC01/20/2009
BISBLISSUEDCHAMPION COMBUSTION CORP08/06/2008
BISOTISSUEDJADE RESTORATION07/10/2007
BISEQISSUEDEVEREST SCAFFOLDING INC06/22/2007
BISOTISSUEDFIVE BORO ROOFING& SHT.METL WKS04/23/2003
BISOTISSUEDFIVE BORO ROOFING& SHT.METL WKS02/27/2002
BISOTISSUEDFIVE BORO ROOFING& SHT.METL WKS04/24/2001
BISEQISSUEDCOLGATE SCAFFOLDING03/26/2001
BISOTISSUEDFIVE BORO ROOFING& SHT.METL WKS07/18/2000
1 project · most recent 07/01/2021
FiledStatusContractorScope
07/01/2021CompleteELPO ELECTRICAL CONTG INC—
▾Special Inspection Requirements (DOB NOW) — 9
DateRequirementInspectorRole
08/22/2024MasonryDavid Salamonspecial
08/22/2024Tenant Protection Plan ComplianceDavid Salamonspecial
08/22/2024FinalDavid Salamonprogress
07/30/2024FinalDavid Salamonprogress
07/30/2024Tenant Protection Plan Compliance—special
07/30/2024MasonryDavid Salamonspecial
04/21/2021Structural Stability – Alterations of existing buildingsATULKUMAR SHAH, PEspecial
03/10/2021MasonryALAN EPSTEINspecial
02/11/2021FinalALAN EPSTEINprogress
▾Documents — 125 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch4
09/03/2026M00561628-I1Request digital key ↗
08/30/2026M00888162-I1Request digital key ↗
08/30/2026M00888162-P1Request digital key ↗
Showing 3 of 4 on file for this type
▸DOB NOWPlans/Sketch - General Construction1
08/15/2026M00469450-I1Request digital key ↗
▸Applications & Permits24
▸BISPLAN / WORK APPROVAL APPLICATION12
09/04/2018123433524Open ↗
08/23/2018123433524Open ↗
05/01/2018123433524Open ↗
Showing 3 of 12 on file for this type
▸BISWORK PERMIT APPLICATION12
05/29/2018123433524Open ↗
05/29/2018123433524Open ↗
06/29/2017122890675Open ↗
Showing 3 of 12 on file for this type
▸Seals & Professional Certifications30
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION9
02/27/2019123433524Open ↗
05/01/2018123433524Open ↗
01/25/2018122890675Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature5
09/20/2026M00888162-P1Open ↗
08/30/2026M00888162-I1Open ↗
08/30/2026M00888162-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/13/2026M00888162-P1Open ↗
08/13/2026M00888162-I1Open ↗
08/13/2026M00561628-I1Open ↗
Showing 3 of 4 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM3
01/23/2012120956545Open ↗
01/07/2009110422891Open ↗
07/24/2008110298865Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST3
01/23/2012120956545Open ↗
01/07/2009110422891Open ↗
07/25/2008110298865Open ↗
▸DOB NOWProgress Inspector Seal & Signature3
09/20/2026M00888162-P1Open ↗
08/30/2026M00888162-I1Open ↗
08/30/2026M00469450-I1Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
11/04/2016140570308Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
11/04/2016140570308Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
11/04/2016140570308Open ↗
▸Trade Schedules & Equipment6
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE2
09/04/2018123433524Open ↗
05/01/2018123433524Open ↗
▸BISSCHEDULE B - PLUMBING1
07/24/2008110298865Open ↗
▸BISBOILERS - SUPPORTING DOCUMENTATION1
06/04/2009110298865Open ↗
▸BISSELF-CERT PLUMBING NOTICE1
05/28/2009110298865Open ↗
▸BISSCHEDULE C - HEATING & COMBUSTION EQUIPMENT1
07/24/2008110298865Open ↗
▸Safety & Tenant Protection5
▸BISTenant Protection Plan and Notes3
05/01/2018123433524Open ↗
09/27/2016122890675Open ↗
11/04/2016140570308Open ↗
▸BISSTREET TREE CHECKLIST1
01/07/2009110422891Open ↗
▸BISDEMOLITION SUBMITTAL CERTIFICATION FORM1
01/04/2017122890675Open ↗
▸Environmental & Asbestos8
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/13/2026M00469450-I1Open ↗
08/13/2026M00888162-P1Open ↗
08/13/2026M00888162-I1Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)2
05/01/2018123433524Open ↗
09/27/2016122890675Open ↗
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'2
09/20/2011120815902Open ↗
07/24/2008110298865Open ↗
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
01/07/2009110422891Open ↗
▸Energy Compliance7
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS4
02/27/2019123433524Open ↗
05/01/2018123433524Open ↗
01/25/2018122890675Open ↗
Showing 3 of 4 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS2
02/27/2019123433524Open ↗
01/25/2018122890675Open ↗
▸BISTR8: Energy Code Progress Inspections1
12/12/2011120815902Open ↗
▸Inspections & Test Reports1
▸BISTECHNICAL REPORT: RESPONSIBILITY1
11/04/2016140570308Open ↗
▸Approvals, Objections & Sign-offs8
▸BISADMINISTRATIVE OBJECTIONS5
01/23/2012120956545Open ↗
09/20/2011120815902Open ↗
01/08/2009110422891Open ↗
Showing 3 of 5 on file for this type
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST3
02/27/2019123433524Open ↗
01/25/2018122890675Open ↗
09/02/2009110298865Open ↗
▸Cost, Insurance & Ownership11
▸BISCOST AFFIDAVIT11
02/27/2019123433524Open ↗
05/01/2018123433524Open ↗
01/25/2018122890675Open ↗
Showing 3 of 11 on file for this type
▸Filing & Intake Forms15
▸BISADDITIONAL INFORMATION5
10/23/2018123433524Open ↗
09/04/2018123433524Open ↗
01/24/2018122890675Open ↗
Showing 3 of 5 on file for this type
▸BISBOROUGH INTAKE FORM4
02/27/2019123433524Open ↗
08/23/2018123433524Open ↗
01/25/2018122890675Open ↗
Showing 3 of 4 on file for this type
▸BISEFILING COVER SHEET4
05/01/2018123433524Open ↗
09/27/2016122890675Open ↗
01/23/2012120956545Open ↗
Showing 3 of 4 on file for this type
▸BISeFiling Job Application Cover Sheet2
07/24/2008110298865Open ↗
11/04/2016140570308Open ↗
▸Other Documents5
▸BISSEPTIC - SUPPORTING DOCUMENTATION1
11/04/2016140570308Open ↗
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION1
09/02/2009110298865Open ↗
▸DOB NOWDHCR Document1
08/13/2026M00469450-I1Open ↗
▸DOB NOWCalculations1
08/13/2026M00976621-I1Open ↗
▸DOB NOWManufacturer's Specifications1
08/13/2026M00976621-I1Open ↗