← Back
Three families
2064 76 STREET
BROOKLYN · BIN 3160973
💬 Discuss this project
1925Year Built
2Stories
C0Building Class
R5Zoning
2,640 sfGross Floor Area
3Units
Rent Stabilized0 Open ViolationsFDNY Report ↗
Three families · 2,400 sf lot · 1.1 FAR built · Flood zone X
Locations of Work
ArchitectureElectricalPlumbingFire Protection
Cellar10p · 1 filing · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
07/10/2024$1.6M—Private party → Private party$625/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NIC 88 CORP402/17/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
BASIC GROUPS803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
CUBE BUILDERS GROUP NYGeneral Contractor107/08/2026
PIPESTYLISTS, INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NIC 88 CORP8371402/17/2025
Building Lifecycle
All (38)Filed (4)Permit Issued (2)Signed Off (1)Violation (5)Inspection (4)Special Inspection (22)
05/01/2026
Violation issued (HPD, closed)
A
06/06/2025
Violation issued (HPD, closed)
A
02/24/2025
Signed off — Alteration
INSTALL NEW BOILER AND H.W.H. IN THE EXISTING 2 STORY BUILDING. INSTALL KITCHEN AND BATHROOM PLUMBING AND GAS FIXTURES. PLUMBING WORKS AS PER PLAN. NO CHANGE IN EGRESS, USE, OR OCCUPANCY.
B01095336-I1
02/17/2025
Filed — Alteration
INSTALL NEW BOILER AND H.W.H. IN THE EXISTING 2 STORY BUILDING. INSTALL KITCHEN AND BATHROOM PLUMBING AND GAS FIXTURES. PLUMBING WORKS AS PER PLAN. NO CHANGE IN EGRESS, USE, OR OCCUPANCY.
B01095336-P2
02/17/2025
Special inspection requirement — Insulation placement and R values
Eric Sun
02/17/2025
Special inspection requirement — Ventilation and air distribution system
Eric Sun
02/17/2025
Special inspection requirement — HVAC-R and service water heating equipment
Eric Sun
02/17/2025
Special inspection requirement — Maintenance information
Eric Sun
02/17/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Eric Sun
02/17/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Eric Sun
02/17/2025
Special inspection requirement — Mechanical Systems
Eric Sun
02/17/2025
Special inspection requirement — Tenant Protection Plan Compliance
Eric Sun
02/17/2025
Special inspection requirement — Energy Code Compliance Inspections
Eric Sun
02/17/2025
Special inspection requirement — Final
Eric Sun
02/17/2025
Special inspection requirement — Fire-Resistance Rated Construction
Eric Sun
02/17/2025
Special inspection requirement — Interior lighting power
Eric Sun
02/17/2025
Special inspection requirement — Duct leakage testing, insulation and design
Eric Sun
02/17/2025
Special inspection requirement — HVAC-R and service water heating system controls
Eric Sun
01/07/2025
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
01/06/2025
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
12/30/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
Eric Sun
12/30/2024
Special inspection requirement — HVAC-R and service water heating equipment
Eric Sun
12/30/2024
Special inspection requirement — HVAC-R and service water heating system controls
Eric Sun
12/27/2024
Filed — Alteration
INSTALL NEW BOILER AND H.W.H. IN THE EXISTING 2 STORY BUILDING. INSTALL KITCHEN AND BATHROOM PLUMBING AND GAS FIXTURES. PLUMBING WORKS AS PER PLAN. NO CHANGE IN EGRESS, USE, OR OCCUPANCY.
B01095336-P1
12/27/2024
Special inspection requirement — HVAC-R and service water heating system controls
Eric Sun
12/27/2024
Special inspection requirement — Energy Code Compliance Inspections
Eric Sun
12/27/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Eric Sun
12/27/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
Eric Sun
12/27/2024
Special inspection requirement — HVAC-R and service water heating equipment
Eric Sun
11/26/2024
Violation issued (HPD, closed)
I
10/09/2024
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
10/09/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
09/24/2024
Permit issued — Plumbing
B01095336-S1-PL
09/19/2024
Filed — Alteration
INSTALL NEW BOILER AND H.W.H. IN THE EXISTING 2 STORY BUILDING. INSTALL KITCHEN AND BATHROOM PLUMBING AND GAS FIXTURES. PLUMBING WORKS AS PER PLAN. NO CHANGE IN EGRESS, USE, OR OCCUPANCY.
B01095336-S1
08/21/2024
Permit issued — Mechanical Systems
B01095336-I1-GC-CX
08/16/2024
Filed — Alteration
INSTALL NEW BOILER AND H.W.H. IN THE EXISTING 2 STORY BUILDING. INSTALL KITCHEN AND BATHROOM PLUMBING AND GAS FIXTURES. PLUMBING WORKS AS PER PLAN. NO CHANGE IN EGRESS, USE, OR OCCUPANCY.
B01095336-I1
04/06/2021
Violation issued (HPD, closed)
A
02/17/2015
Violation issued (HPD, closed)
I
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offT & T PLUMBING INC09/24/2024
DOB NOWMechanical SystemsSigned-offCUBE BUILDERS GROUP NY08/21/2024
1 project · most recent 02/17/2025
Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
02/17/2025Signed-offCUBE BUILDERS GROUP NYAir Conditioning Systems
Cooling
Mitsubishi Electric MUZ-GL09NA 9,000 BTU · Condensing Unit ×3
Fujitsu MUZ-GL24NA 27,600 BTU · Condensing Unit ×1
1 project · most recent 02/17/2025
Gas Water/Sanitary
FiledStatusContractorScope
02/17/2025Signed-offT & T PLUMBING INCGas, Water/Sanitary
1 project · most recent 09/06/2024
General Wiring
FiledStatusContractorScope
09/06/2024CompleteJ Y ELECTRIC INCGeneral Wiring
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
01/07/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
01/06/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
10/09/2024Certified Gas-Gas-Piping-RoughingCertifiedView ↗
10/09/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 22
DateRequirementInspectorRole
02/17/2025Insulation placement and R valuesEric Sunenergy_progress
02/17/2025Ventilation and air distribution systemEric Sunenergy_progress
02/17/2025HVAC-R and service water heating equipmentEric Sunenergy_progress
02/17/2025Maintenance informationEric Sunenergy_progress
02/17/2025HVAC-R and service water piping design and insulationEric Sunenergy_progress
02/17/2025Fire-Resistant Penetrations and JointsEric Sunspecial
02/17/2025Mechanical SystemsEric Sunspecial
02/17/2025Tenant Protection Plan ComplianceEric Sunspecial
02/17/2025Energy Code Compliance InspectionsEric Sunprogress
02/17/2025FinalEric Sunprogress
02/17/2025Fire-Resistance Rated ConstructionEric Sunprogress
02/17/2025Interior lighting powerEric Sunenergy_progress
02/17/2025Duct leakage testing, insulation and designEric Sunenergy_progress
02/17/2025HVAC-R and service water heating system controlsEric Sunenergy_progress
12/30/2024HVAC-R and service water piping design and insulationEric Sunenergy_progress
12/30/2024HVAC-R and service water heating equipmentEric Sunenergy_progress
12/30/2024HVAC-R and service water heating system controlsEric Sunenergy_progress
12/27/2024HVAC-R and service water heating system controlsEric Sunenergy_progress
12/27/2024Energy Code Compliance InspectionsEric Sunprogress
12/27/2024Fire-Resistant Penetrations and JointsEric Sunspecial
12/27/2024HVAC-R and service water piping design and insulationEric Sunenergy_progress
12/27/2024HVAC-R and service water heating equipmentEric Sunenergy_progress
▾Documents — 20 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/22/2026B01095336-S1Request digital key ↗
08/22/2026B01095336-I1Request digital key ↗
08/22/2026B01095336-P1Request digital key ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications12
▸DOB NOWProgress Inspector Seal & Signature6
09/01/2026B01095336-P1Open ↗
09/01/2026B01095336-P1Open ↗
08/25/2026B01095336-S1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/22/2026B01095336-I1Open ↗
08/22/2026B01095336-S1Open ↗
08/22/2026B01095336-P2Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature2
09/01/2026B01095336-P1Open ↗
08/23/2026B01095336-P2Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/22/2026B01095336-I1Open ↗
08/22/2026B01095336-P2Open ↗
08/22/2026B01095336-P1Open ↗
Showing 3 of 4 on file for this type