DOB11/14/2025VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
ECB11/03/2025FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AT TIME OF INSPECTION OBSERVED CRACKSAND MISSING MORTAR JOINT ON EXP #1 AND ALSO ON EXP #4. REMEDY: REPAIR AND REPLACE.$12K due
ECB01/29/2025FAILURE TO COMPLY WITH COMMISSIONER'S ORDER CONTAINED IN SUMMONS #39075326J ISSUED ON 12/08/2022, AND FAILURE TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28.201.1 AND 1 RCNY 102-01(D)(2). AN ACCEPTABLE CERT$6K due
DOB09/23/2024VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION
ECB05/23/2024OBSERVED A BURNHAM BOILER MODEL SIN5LNI SERIAL# 65302615 WITH STORAGE IN BOILER ROOM, MISSING CHIMNEY CLEANOUT , MISSING FIRE DAMPER ON COMBUSTION AIR INTAKE. CORRECT ALL VIOLATING CONDITIONS AND SUBMIT A CERTI$3K due
DOB06/30/2023VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION
DOB06/30/2023VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION
DOB06/20/2023VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION
DOB06/20/2023VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
DOB04/25/2023VIOLATION ISSUED-FAILURE TO FILE 2022 EXTERNAL LOW PRESSURE INSPECTION
ECB12/08/2022FOUND FULTON OIL FIRED BOILER MODEL FB-10 NB#116499 ACTIVE AND OPERATING WITH DEFECTS. CHIMNEY CLEANOUT NOT FOUND. DOOR NOT SELF CLOSING DUE TO PIPE RUN ACROSS DOOR OPENING. CORRECT ALL VIOLATING CONDITIONS AND$315 due
DOB11/08/2019VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2017 INSPECTION REPORT
DOB04/06/2018VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT
DOB02/24/2017VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2015 INSPECTION REPORT
DOB10/01/2015VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2014 INSPECTION REPORT
DOB03/03/2015VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2013 INSPECTION REPORT
DOB05/15/2014VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT
DOB03/01/2013VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2011 INSPECTION REPORT
DOB12/13/2011VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2010 INSPECTION REPORT
DOB01/01/2009V-DOB VIOLATION - ACTIVE
DOB01/03/2008V-DOB VIOLATION - ACTIVE
DOB01/19/2007V-DOB VIOLATION - ACTIVE
DOB01/06/2006V-DOB VIOLATION - ACTIVE
DOB01/31/2005V-DOB VIOLATION - ACTIVE
DOB02/13/2004V-DOB VIOLATION - ACTIVE
DOB03/19/2003V-DOB VIOLATION - ACTIVE
DOB03/26/2002V-DOB VIOLATION - ACTIVE
DOB02/27/2001V-DOB VIOLATION - ACTIVE
DOB02/07/2000V-DOB VIOLATION - ACTIVE
DOB03/16/1999V-DOB VIOLATION - ACTIVE
DOB05/04/1998V-DOB VIOLATION - ACTIVE
DOB09/16/1997V-DOB VIOLATION - ACTIVE
DOB02/10/1997V-DOB VIOLATION - ACTIVE
DOB08/29/1995V-DOB VIOLATION - ACTIVE
DOB06/07/1994V-DOB VIOLATION - ACTIVE
DOB06/28/1993V-DOB VIOLATION - ACTIVE
ECB03/15/2022REMOVE STORAGE,PIPE LEAKING ON FITTING BY LOW WTR CUT OFF ,WHICH IS TOO LOW & NEEDS TO BE RELOCATED,SEAL BASE OF CHIMNEY & INSTALL CLEAN OUT,MISSING FIRE DAMPERS FOR COMBUSTION AIR REMOVE CLOGGED SCREEN HOLES TNothing owed — awaiting certificate of correction
ECB08/17/201836,4A,15,38,50A,50B,50C,50D. B254-36 FOUND PENNCO GAS FIRED BOILER NOT REGISTERED 50A-WRONG MATERIAL FOR PIPE SUPPORT; B-NO FLUE SUPPORT C-DISCHARGE ON BOILER RELIEF VALVE WRONG MATERIAL; D-NO SIGNAGE ON DOONothing owed — awaiting certificate of correction
ECB05/19/2017AS PER CLASS 2 (B265) 28-303.7 FAILURE TO FILE A COMPLETE BOILER INSPECTION REPORT AS PER DOB RECORDS. SUBMIT A CURRENT B09 REPORT.Nothing owed — awaiting certificate of correction
ECB12/02/1999OCCUPANCY CONTRARY TO THAT ALLOWED BY THE DEPT OF BUILDINGS RECORD ILLEGAL OCCUPANCY NOTED AT REAR OF STORE WALLS ERECTED CREATING 2 BED-ROOMS, KITCHEN WITH ELECTRIC STOVE, AND A 3 PC. BATHROOM. RESIDENCENothing owed — awaiting certificate of correction
ECB02/09/199818A,18B,Nothing owed — awaiting certificate of correction