Walk-up apt, over six families with stores
207 AVENUE B
MANHATTAN · East Village · BIN 1076878
💬 Discuss this project
1900Year Built
4Stories
C7Building Class
R7AZoning
6,432 sfGross Floor Area
21Units
Rent Stabilized155 Open Violations 141 unresolved · 14 paperwork only ▸
Walk-up apt, over six families with stores · Owner of record: CRISARI REALTY INC · 2,232 sf lot · 2.88 FAR built · Flood zone X500
Locations of Work
Architecture
Roof1p · 1 filing · 14 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
CRISARI REALTY5409/14/2026
ALL EMPIRE BUILDING CONTRACTORS1007/08/2026
RED HILL CONSTRUCTION503/22/2026
RENNON CONSTRUCTION403/22/2026
OWNER OF 207 AVENUE B203/22/2026
RENAON CONSTRUCTION CORP103/22/2026
207 AVE B CORP CRISARI REALTY503/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
G R RESTIVO AIA507/24/2026
MELDAN GROUP LLC111/23/2024
SYED ENGINEERING, P.C.209/06/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
NOEL BUILDING CONSULTING INC403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ALL EMPIRE BUILDING CONGeneral Contractor607/08/2026
NEW FEDCO GENERAL CONTRACGeneral Contractor303/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
MELDAN GROUP LLC8100407/24/2026
Building Lifecycle
All (113)Filed (8)Permit Issued (5)Signed Off (1)Violation (60)Objection (10)Special Inspection (29)
09/14/2026
Special inspection requirement — Masonry
09/14/2026
Special inspection requirement — Fire-Resistance Rated Construction
George Restivo
09/09/2026
Objection resolved — Addressed
09/09/2026
Objection resolved — Addressed
09/09/2026
Objection resolved — Addressed
09/09/2026
Objection resolved — Addressed
08/25/2026
Special inspection requirement — Structural Steel - High Strength Bolting
08/25/2026
Special inspection requirement — Fire-Resistance Rated Construction
08/25/2026
Special inspection requirement — Concrete - Cast-In-Place
08/25/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
08/25/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
08/25/2026
Special inspection requirement — Masonry
08/25/2026
Special inspection requirement — Structural Steel - Details
08/25/2026
Special inspection requirement — Wood – Seismic Resistance
08/25/2026
Special inspection requirement — Final
08/24/2026
Objection resolved — Resolved
08/19/2026
Violation issued (HPD, open)
B
08/19/2026
Violation issued (HPD, open)
B
08/19/2026
Violation issued (HPD, open)
B
08/19/2026
Violation issued (HPD, open)
B
08/19/2026
Violation issued (HPD, open)
B
08/19/2026
Violation issued (HPD, open)
A
08/19/2026
Violation issued (HPD, open)
B
08/19/2026
Violation issued (HPD, open)
B
08/19/2026
Violation issued (HPD, open)
C
08/19/2026
Violation issued (HPD, open)
B
08/19/2026
Violation issued (HPD, open)
A
08/19/2026
Violation issued (HPD, open)
B
08/19/2026
Violation issued (HPD, open)
B
08/19/2026
Violation issued (HPD, open)
B
08/19/2026
Violation issued (HPD, open)
C
08/19/2026
Violation issued (HPD, open)
B
08/15/2026
Objection raised — Cost
07/29/2026
Objection raised — Other
07/29/2026
Objection raised — Other
07/27/2026
Objection raised — Scope
07/27/2026
Objection raised — Inspections
07/24/2026
Filed — Alteration
STRUCTURAL REPAIRS THROUGHOUT THE BUILDING AS PER PLANS PROVIDED. REPAIRS INCLUDE STRENGTHENING THE EXTERIOR WALLS AFFECTED BY RECENT WORK OR NORMAL DETERIORATION, REPLACE DAMAGED GIRDERS AT THE CELLAR AND DAMAGED FLOOR BEAMS AT FLOORS 001 THROUGH 004.
M01156666-P1
07/24/2026
Filed — Alteration
Filing to complete facade work started under application 122760333. Updated and amended plans filed herewith.
M08025026-P2
07/22/2026
Special inspection requirement — Fire-Resistance Rated Construction
07/22/2026
Special inspection requirement — Wood – Seismic Resistance
07/22/2026
Special inspection requirement — Tenant Protection Plan Compliance
07/22/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
Jeffrey Reid
07/22/2026
Special inspection requirement — Final
George Restivo
07/22/2026
Special inspection requirement — Concrete - Cast-In-Place
07/22/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
07/22/2026
Special inspection requirement — Masonry
07/22/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
07/22/2026
Special inspection requirement — Structural Steel - Details
07/22/2026
Special inspection requirement — Structural Steel - High Strength Bolting
07/22/2026
Special inspection requirement — Final
02/24/2026
Violation issued (HPD, open)
A
02/24/2026
Violation issued (HPD, open)
C
02/24/2026
Violation issued (HPD, closed)
C
12/31/2025
Violation issued (ECB, open)
Construction
12/31/2025
Violation issued (ECB, open)
Construction
12/31/2025
Violation issued (ECB, open)
Construction
12/31/2025
Violation issued (ECB, open)
Construction
12/31/2025
Violation issued (ECB, open)
Construction
11/14/2025
Violation issued (HPD, open)
B
Latest 60 of 113 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSidewalk ShedPermit IssuedALL EMPIRE BUILDING CON09/12/2023
DOB NOWSupported ScaffoldPermit IssuedALL EMPIRE BUILDING CON08/14/2023
DOB NOWGeneral ConstructionPermit IssuedNEW FEDCO GENERAL CONTRAC05/23/2023
DOB NOWSidewalk ShedPermit IssuedALL EMPIRE BUILDING CON09/15/2021
DOB NOWSupported ScaffoldPermit IssuedALL EMPIRE BUILDING CON09/15/2021
BISEQISSUEDRENNON CONSTRUCTION CORP01/08/2020
BISEQISSUEDRENNON CONSTRUCTION CORP10/19/2018
BISEQISSUEDRENNON CONSTRUCTION CORP10/19/2018
BISOTISSUEDRED HILL CONSTRUCTION INC08/08/2018
BISEQISSUEDRENNON CONSTRUCTION CORP10/23/2017
BISEQISSUEDRENNON CONSTRUCTION CORP10/23/2017
BISOTISSUEDRED HILL CONSTRUCTION INC10/04/2017
BISOTISSUEDLUCKY GENERAL CONSTR CORP05/12/2017
BISOTISSUEDMALI CONSTRUCTION NY CORP12/21/2016
BISOTISSUEDMALI CONSTRUCTION NY CORP10/24/2016
BISEQISSUEDRENNON CONSTRUCTION CORP10/14/2016
BISEQISSUEDRENNON CONSTRUCTION CORP10/14/2016
BISOTISSUEDALL BOROS CONTRACTING INC05/24/2016
1 project · most recent 07/24/2026
Steel Masonry Wood
FiledStatusContractorScope
07/24/2026——Steel, Masonry, Wood
1 project · most recent 09/06/2021
Sidewalk Shed
FiledStatusContractorScope
09/06/2021Permit IssuedALL EMPIRE BUILDING CONSidewalk Shed
▾Special Inspection Requirements (DOB NOW) — 29
DateRequirementInspectorRole
09/14/2026Masonry—special
09/14/2026Fire-Resistance Rated ConstructionGeorge Restivoprogress
08/25/2026Structural Steel - High Strength Bolting—special
08/25/2026Fire-Resistance Rated Construction—progress
08/25/2026Concrete - Cast-In-Place—special
08/25/2026Fire-Resistant Penetrations and Joints—special
08/25/2026Structural Stability – Alterations of existing buildings—special
08/25/2026Masonry—special
08/25/2026Structural Steel - Details—special
08/25/2026Wood – Seismic Resistance—special
08/25/2026Final—progress
07/22/2026Fire-Resistance Rated Construction—progress
07/22/2026Wood – Seismic Resistance—special
07/22/2026Tenant Protection Plan Compliance—special
07/22/2026Structural Stability – Alterations of existing buildingsJeffrey Reidspecial
07/22/2026FinalGeorge Restivoprogress
07/22/2026Concrete - Cast-In-Place—special
07/22/2026Fire-Resistant Penetrations and Joints—special
07/22/2026Masonry—special
07/22/2026Structural Stability – Alterations of existing buildings—special
07/22/2026Structural Steel - Details—special
07/22/2026Structural Steel - High Strength Bolting—special
07/22/2026Final—progress
01/18/2024Structural Stability – Alterations of existing buildingsJeffrey Reidspecial
01/18/2024FinalGeorge Restivoprogress
Latest 25 of 29.
▾Documents — 61 on file (BIS + DOB NOW)
▸Plans & Drawings8
▸DOB NOWPlans/Sketch8
09/03/2026M00585131-I1Request digital key ↗
09/03/2026M00585138-I1Request digital key ↗
09/01/2026M08025026-P1Request digital key ↗
Showing 3 of 8 on file for this type
▸Applications & Permits16
▸BISWORK PERMIT APPLICATION12
01/08/2020122896517Open ↗
10/19/2018122896802Open ↗
10/19/2018122896517Open ↗
Showing 3 of 12 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION4
12/05/2023122760333Open ↗
10/20/2016122896802Open ↗
10/20/2016122896517Open ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications24
▸DOB NOWDPL-1: Design Professional Seal & Signature8
09/03/2026M00585138-I1Open ↗
09/01/2026M08025026-I1Open ↗
09/01/2026M08025026-P2Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWProgress Inspector Seal & Signature4
09/15/2026M08025026-I1Open ↗
09/02/2026M08025026-P1Open ↗
09/01/2026M08025026-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
09/02/2026M08025026-P1Open ↗
09/01/2026M08025026-I1Open ↗
09/01/2026M08025026-I1Open ↗
Showing 3 of 4 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT3
10/20/2016122896802Open ↗
10/20/2016122896517Open ↗
04/11/2016122760333Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST3
10/20/2016122896802Open ↗
10/20/2016122896517Open ↗
04/11/2016122760333Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION2
10/20/2016122896517Open ↗
04/11/2016122760333Open ↗
▸Safety & Tenant Protection2
▸BISTenant Protection Plan and Notes2
10/20/2016122896802Open ↗
10/20/2016122896517Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/25/2026M01143057-I1Open ↗
08/22/2026M01156666-P1Open ↗
08/13/2026M01156666-I1Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
10/20/2016122896517Open ↗
▸Energy Compliance1
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
04/11/2016122760333Open ↗
▸Approvals, Objections & Sign-offs2
▸BISSUPERSEDING LETTER2
10/05/2017122760333Open ↗
11/07/2016122760333Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
04/11/2016122760333Open ↗
▸Filing & Intake Forms3
▸BISEFILING COVER SHEET3
10/20/2016122896802Open ↗
10/20/2016122896517Open ↗
04/11/2016122760333Open ↗