HPD08/12/2026§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIALS AT ELECTRICAL METER ROOM CEILING , 1st STORY
ECB07/17/2026FAILURE TO PROVIDE ADEQUATE SAFETY MEASURES SUCH AS SHED, NETTING ETC.WHERE REQUIRED TO PROTECT PUBLIC AND PROPERTY FROM DOCUMENTED UNSAFE FACADE AS PER 1 RCNY 103-04.-UNSAFE NOTIFICATION UNSAFE-#1006695-10A-00$10K due
ECB05/12/2026EXPIRED SIDEWALK SHED, AT TIME OF INSPECTION OBSERVED FULLY CONSTRUCTED SIDEWALK SHED ON PREMISES. NO VALID SIDEWALK SHED POSTED ON PREMISESOR ANY DOB DATABASE LAST VALID SIDEWALK SHED WAS EXPIRED ON 05/07/2026$6K due
DOB05/12/2026FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER AS PER SECTION 28.301.1 OF THE NYC ADMIN CODE.NOTED AT TIME OF INSPECTION,OBSERVED AT AND THROUGH ALL EXPOSURES,SPALLED BRICK,LOOSE AND DETERIORATED MORATR JOINTS.REMEDY:REPAIR AND/OR REPLACE
ECB04/20/2026FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 8A REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL FACADES REPORT REQUIRED BY 28-302.5 FOR CONTROL #806695. AGG1: PRIOR NOV 37026507P UNDER 28-302$3K due
ECB10/21/2025AT TIME OF INSPECTION OF 11 STORY MIXED USE BUILDING OBSERVED PERMITTED SIDEWALK SHED IN PLACE NOT MAINTAINED WITH MUDSILLS ROTTING CAUSING HAZARDOUS CONDITIONS.MAINTAIN$10K due
HPD08/24/2025§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THAN 10SQ FT AT WEST WALL IN THE BATHROOM LOCATED AT APT 3S, 3rd STORY, 3rd APARTMENT FROM WEST AT NORTH
HPD08/20/2025§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THAN 10 SQ FT AT CEILING AND WEST WALL IN THE BATHROOM LOCATED AT APT 3S, 3rd STORY, 3rd APARTMENT FROM WEST AT NORTH
ECB06/27/2025AT TIME OF INSPECTION, OBSERVED MULTIPLE ROTTED STEEL BASE POSTS, MISSING BRACING, AND NON-FUNCTIONING LIGHTS UNDER AN ACTIVE SIDEWALK SHED WITH NO PLANS ON SITE AND NO VISIBLE ROOFTOP WORK, POSING A HAZARD TO$2K due
DOB03/18/2025FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER.OBSERVED ON AL L EXPOSURES SPALLED BRICKS AND MORTAR JOINTS IN MULTIPLE LOCATIONS AND FLOORS.REMEDY:REPAIR AND/OR REPLACE DAMAGED FACADE AND APPURTENANCES
ECB03/18/2025TEMP CONSTRUCTION EQUIP/INSTALLATION ON SITE EXPIRED PERMIT(SHED). AS OF TODAY 03/18/2025 PERMIT #M00063449-I1-SH EXPIRED ON 03/06/2025 NO CURRENT PERMIT. REMEDY: RENEW PERMIT.
ECB11/19/20243314 I OBSEVERED 11-STORY BUILDING NONE ACTIVE JOBSITE I OBSERVED PIPE SCAFFOLD EXP#3 NOT CODE COMPLYING.UPON DOING MY INSPECTION, I NOTICED PIPE SCAFFOLD WITH MISSING TOE BOARDS, GUARD RAILS AND NOT FULLY PLAN$2K due
ECB10/28/2024CLASS 2: PHONE INOPERATIVE REPAIR & PROGRAM TO 24 HR EMERGENCY OPERATOR. CAR DOOR MISALIGNED CAUSING RUBBING/SCRAPPING ADJUST TO REMOVE. NO ACCESS TO MOTOR ROOM PROVIDE ACCESS.$625 due
ECB10/28/2024CLASS 2: PHONE INOPERATIVE REPAIR & CONNECT SERVICE TO 24 HR EMERGENCY OPERATOR. CAR DOOR MISALIGNED ADJUST. NO ACCESS TO MOTOR ROOM PROVIDE ACCESS. CARTOP NOT TAGGED WITH DEVICE NUMBER PROVIDE NYC ID TAG.$625 due
DOB10/01/2024FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER.AS NOTED AT TI ME OF INSPECTION I OBSERVED ON EXP1,2,3,4 SPALLING BRICKS AND MORTAR J OINTS ON MULTIPLE FLOORS AND LOCATIONS.REMEDY:REPAIR AND/OR REPAIR ALL DAMAGED DEFECTIVE FACADE AND APPURTENANCES
ECB08/05/2024AT TIME OF INSPECTION OBSERVED SIDEWALK SHED ERECTED AT EXPOSURE #1-2-3.OBSERVED THE STEEL RAILING WAS NOT SECURE TO THE COLUMN AND ,MISSING CAPS FROM THE BOLTS 3307.6.5.6 SHARP EDGES.CREATING A HAZARD CONDITI$2K due
DOB06/23/2024FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2023)
DOB05/16/2024FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER.NOTE OBSERVED AT EXP2 EAST ELEVATION,MISSING WINDOW GLASS AT 3RD FLOOR SE CORNER.REM EDY:FIX AND/OR REPLACE
ECB02/15/2024FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 8A REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL FACADES REPORT REQUIRED BY 28-302.5 FOR CONTROL #806695. REMEDY: FILE ACCEPTABLE REPORT.$1K due
ECB08/07/2023EMERGENCY PHONE NOT WORKING;REPAIR; REPAIR FAN INSIDE ELEVATOR$3K due
ECB02/02/2023CLASS 1: ZONE RESTRICTOR INOPERATIVE. CEASE USE. CLASS 2: IN CAR COMMUNICATION INOPERATIVE, REPAIR. PIT DIRTY, CLEAN. FIRE EXTINGUISHER IN THE MACHINE ROOM EXPIRED, UPDATE.$1K due
ECB01/13/2023FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 9A REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL#906695.REM:SUBMIT ACCEPTABLE REQUIRED T$1K due
DOB02/22/2022FAILED TO FILE FISP CYCLE 9A TECHNICAL REPORT BY 02/21/2022
DOB06/20/2021FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2020)
DOB06/29/2020FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 IN 2019
DOB06/19/2018V-DOB VIOLATION - ACTIVE
DOB05/31/2018FAILED TO FILE FISP CYCLE 8A TECHNICAL REPORT BY 02/21/2017
ECB08/02/2024AT TIME OF INSPECTION I OBSERVED SIDEWALK SHED IN PLACE AT EXPOSURE # 1 AND 2 OF THE BUILDING WITH EXPIRED PERMIT SINCE 7-17-2024BY COMPLY WITH CODENothing owed — awaiting certificate of correction