← Back
Four families
2071 68 STREET
BROOKLYN · BIN 3134770
💬 Discuss this project
1931Year Built
2Stories
C3Building Class
R5Zoning
3,510 sfGross Floor Area
4Units
Rent Stabilized1 Open Violation ▸FDNY Report ↗
Four families · 3,167 sf lot · 1.11 FAR built · Flood zone X
Locations of Work
Architecture
Permit Issued — active, not yet Signed-off
Floor 2Under Construction1 filing · 5 docs
Floor 11p · 1 filing · 6 docs
Cellar3p · 1 filing · 9 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
ELAINE209/15/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
01/07/2021$1.7M—Private party → Private party$484/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ISEED CONSTRUCTION INC109/09/2026
S M TAM ARCHITECT, PLLC302/27/2024
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
HENRYSMITH PROPERTY MGMTGeneral Contractor207/08/2026
BUILDER BROTHER GROUP INCGeneral Contractor107/08/2026
NOOR MECHANICAL SERVICESGeneral Contractor109/15/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ISEED CONSTRUCTION INC8336109/09/2026
SD TESTING & INSPECTION S7010102/27/2024
Building Lifecycle
All (38)Filed (4)Permit Issued (4)Signed Off (2)Violation (19)Special Inspection (9)
09/14/2026
Permit issued — General Construction
B01456385-I1-GC
09/09/2026
Filed — Alteration
MINOR RENOVATION OF EXISTING 1 UNIT IN EXISTING 4 FAMILY HOUSE, REPAIR EXISTING STAIR IN CORRIDOR
B01456385-I1
09/09/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
YIPENG LUAN
09/09/2026
Special inspection requirement — Tenant Protection Plan Compliance
YIPENG LUAN
09/04/2026
Special inspection requirement — Final
YIPENG LUAN
05/01/2026
Violation issued (HPD, closed)
A
06/06/2025
Violation issued (HPD, closed)
A
03/31/2025
Violation issued (HPD, open)
B
02/11/2025
Violation issued (HPD, closed)
C
02/11/2025
Violation issued (HPD, closed)
B
02/11/2025
Violation issued (HPD, closed)
A
02/11/2025
Violation issued (HPD, closed)
B
02/11/2025
Violation issued (HPD, closed)
A
02/11/2025
Violation issued (HPD, closed)
A
02/11/2025
Violation issued (HPD, closed)
B
02/11/2025
Violation issued (HPD, closed)
A
02/11/2025
Violation issued (HPD, closed)
A
02/11/2025
Violation issued (HPD, closed)
C
12/20/2024
Violation issued (HPD, closed)
C
06/13/2024
Signed off — Alteration
INTERIOR RENOVATION OF UNIT 1R WITH MINOR CHANGED TO PARTITION AT FIRST FLOOR ONLY. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
B01001468-I1
04/08/2024
Violation issued (HPD, closed)
A
03/21/2024
Permit issued — General Construction
B01001468-I1-GC
02/27/2024
Filed — Alteration
INTERIOR RENOVATION OF UNIT 1R WITH MINOR CHANGED TO PARTITION AT FIRST FLOOR ONLY. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
B01001468-I1
02/26/2024
Special inspection requirement — Interior lighting power
XIUCHENG LI
02/19/2024
Special inspection requirement — Tenant Protection Plan Compliance
XIUCHENG LI
02/19/2024
Special inspection requirement — Final
XIUCHENG LI
03/21/2023
Violation issued (HPD, closed)
A
12/06/2022
Signed off — Alteration
B00477048-I1
10/18/2022
Special inspection requirement — Energy Code Compliance Inspections
NITHIN JOHN
10/18/2022
Special inspection requirement — Final
NITHIN JOHN
10/18/2022
Special inspection requirement — Fire-Resistance Rated Construction
NITHIN JOHN
10/14/2022
Filed — Alteration
B00477048-P1
02/22/2022
Violation issued (HPD, closed)
I
02/22/2022
Violation issued (HPD, closed)
A
12/14/2021
Permit issued — General Construction
B00477048-I1-GC
04/27/2021
Permit issued — General Construction
B00477048-I1-GC
04/06/2021
Violation issued (HPD, closed)
A
03/12/2021
Filed — Alteration
B00477048-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedNOOR MECHANICAL SERVICES09/14/2026
DOB NOWGeneral ConstructionSigned-offBUILDER BROTHER GROUP INC03/21/2024
DOB NOWGeneral ConstructionSigned-offHENRYSMITH PROPERTY MGMT12/14/2021
DOB NOWGeneral ConstructionSigned-offHENRYSMITH PROPERTY MGMT04/27/2021
Nothing on file for this building.
▾Special Inspection Requirements (DOB NOW) — 9
DateRequirementInspectorRole
09/09/2026Fire-Resistant Penetrations and JointsYIPENG LUANspecial
09/09/2026Tenant Protection Plan ComplianceYIPENG LUANspecial
09/04/2026FinalYIPENG LUANprogress
02/26/2024Interior lighting powerXIUCHENG LIenergy_progress
02/19/2024Tenant Protection Plan ComplianceXIUCHENG LIspecial
02/19/2024FinalXIUCHENG LIprogress
10/18/2022Energy Code Compliance InspectionsNITHIN JOHNprogress
10/18/2022FinalNITHIN JOHNprogress
10/18/2022Fire-Resistance Rated ConstructionNITHIN JOHNprogress
▾Documents — 20 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch2
09/15/2026B01456385-I1Request digital key ↗
08/25/2026B01001468-I1Request digital key ↗
▸DOB NOWPlans/Sketch - General Construction2
09/01/2026B00477048-P1Request digital key ↗
09/01/2026B00477048-I1Request digital key ↗
▸Seals & Professional Certifications12
▸DOB NOWProgress Inspector Seal & Signature6
09/23/2026B01456385-I1Open ↗
08/30/2026B00477048-I1Open ↗
08/30/2026B00477048-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
09/15/2026B01456385-I1Open ↗
09/01/2026B00477048-P1Open ↗
09/01/2026B00477048-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature2
09/23/2026B01456385-I1Open ↗
08/24/2026B01001468-I1Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
09/15/2026B01456385-I1Open ↗
09/01/2026B00477048-P1Open ↗
09/01/2026B00477048-I1Open ↗
Showing 3 of 4 on file for this type