← Back
BuildNYC
Two family converted from one family
2071 EAST 2ND STREET
BROOKLYN · BIN 3191691
💬 Discuss this project
1925Year Built
2Stories
B3Building Class
R3-1Zoning
1,480 sfGross Floor Area
2Units
Two family converted from one family · 2,600 sf lot · 0.57 FAR built · Flood zone X
Locations of Work
General
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Permit Issued — active, not yet Signed-off
Floor 31 filing · 20 docs
Floor 21 filing · 20 docs
Floor 11 filing · 20 docs
Cellar1 filing · 20 docs
Site & exteriorPlywood construction fence installationUnder Construction1p · 1 filing · 2 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
07/08/2025$3.6M—Private party → Private party$2,432/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Hesham Elshamy PE509/22/2026
Eyal Levitt Architect303/20/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
DCS803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
RHY ConstructionScaffold109/24/2026
Building Lifecycle
All (86)Filed (8)Permit Issued (1)Objection (47)Special Inspection (30)
10/15/2026
Objection resolved — Resolved
10/14/2026
Objection raised — Other
10/05/2026
Objection raised — Structural
10/05/2026
Objection raised — Structural
10/05/2026
Objection raised — Structural
10/05/2026
Objection raised — Structural
10/05/2026
Objection raised — Structural
10/05/2026
Objection raised — Admin
10/02/2026
Objection raised — Structural
10/02/2026
Objection raised — Admin
10/02/2026
Objection raised — Admin
10/02/2026
Objection raised — Fire_Protection
10/02/2026
Objection raised — Structural
09/29/2026
Objection raised — Scope
09/29/2026
Objection resolved — Addressed
09/23/2026
Permit issued — Construction Fence
B01339011-I1-FN
09/22/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
Horizontal and vertical enlargement to a semi detached single family residence. Remove entire wood frame and upgrade construction class.
B01339002-S6
09/20/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
Horizontal and vertical enlargement to a semi detached single family residence. Remove entire wood frame and upgrade construction class.
B01339002-S5
09/20/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
Horizontal and vertical enlargement to a semi detached single family residence. Remove entire wood frame and upgrade construction class.
B01339002-S4
09/03/2026
Objection raised — Energy
08/13/2026
Objection raised — Scope
08/13/2026
Objection resolved — Addressed
08/04/2026
Special inspection requirement — Electric vehicle service equipment requirements
08/04/2026
Special inspection requirement — Interior lighting power
08/04/2026
Special inspection requirement — Maintenance information
08/04/2026
Special inspection requirement — Metering
06/22/2026
Objection resolved — Addressed
06/22/2026
Objection resolved — Addressed
06/10/2026
Special inspection requirement — Fire-Resistance Rated Construction
06/10/2026
Special inspection requirement — Protection of exposed foundation insulation
06/10/2026
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
06/10/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
06/10/2026
Special inspection requirement — Masonry
06/10/2026
Special inspection requirement — Energy Code Compliance Inspections
05/13/2026
Special inspection requirement — Structural Steel - Details
05/13/2026
Special inspection requirement — Masonry
05/13/2026
Special inspection requirement — Structural Cold-Formed Steel
05/13/2026
Special inspection requirement — Final
05/13/2026
Special inspection requirement — Footing and Foundation
05/12/2026
Special inspection requirement — Final
05/07/2026
Objection resolved — Addressed
05/05/2026
Objection resolved — Addressed
04/22/2026
Objection resolved — Resolved
04/22/2026
Objection resolved — Resolved
04/22/2026
Objection resolved — Addressed
03/30/2026
Objection raised — Cost
03/30/2026
Objection raised — Scope
03/20/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
Horizontal and vertical enlargement to a semi detached single family residence. Remove entire wood frame and upgrade construction class.
B01339002-S3
03/20/2026
Special inspection requirement — Ventilation and air distribution system
03/05/2026
Objection raised — Cost
03/05/2026
Objection raised — Scope
03/05/2026
Objection raised — Scope
03/05/2026
Objection raised — Scope
03/02/2026
Special inspection requirement — Post-installed Anchors
03/02/2026
Special inspection requirement — Heating Systems
03/02/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
03/02/2026
Special inspection requirement — Duct leakage testing, insulation and design
03/02/2026
Special inspection requirement — HVAC-R and service water heating system controls
03/02/2026
Special inspection requirement — HVAC-R and service water heating equipment
03/02/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Latest 60 of 86 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWConstruction FencePermit IssuedRHY Construction09/23/2026
1 project · most recent 09/22/2026
Heating and Air Conditioning Systems Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
09/22/2026——Heating and Air Conditioning Systems, Heating Systems, Ventilation Systems
Heat / Cool
Mitsubishi Electric PUHY-EP144TNU 144,000 BTU · Vrf Outdoor ×1
Heating
Nti TFTN 399 399,000 BTU · Boiler ×1
Ventilation
Panasonic FV-0511VF1 80 CFM · Exhaust Fan ×6
FV-0511VQ 120 CFM · Kitchen Exhaust ×1
1 project · most recent 09/22/2026
Sprinkler System
FiledStatusContractorScope
09/22/2026——Sprinkler System
1 project · most recent 09/22/2026
Gas Storm Water/Sanitary
FiledStatusContractorScope
09/22/2026——Gas, Storm, Water/Sanitary
1 project · most recent 09/22/2026
Steel Masonry
FiledStatusContractorScope
09/22/2026——Steel, Masonry
1 project · most recent 01/06/2026
Fence
FiledStatusContractorScope
01/06/2026Permit IssuedRHY ConstructionFence
▾Special Inspection Requirements (DOB NOW) — 43
DateRequirementInspectorRole
08/04/2026Electric vehicle service equipment requirements—energy_progress
08/04/2026Interior lighting power—energy_progress
08/04/2026Maintenance information—energy_progress
08/04/2026Metering—energy_progress
06/10/2026Fire-Resistance Rated Construction—progress
06/10/2026Protection of exposed foundation insulation—energy_progress
06/10/2026Exterior Insulation and Finish Systems (EIFS)—special
06/10/2026Fire-Resistant Penetrations and Joints—special
06/10/2026Masonry—special
06/10/2026Energy Code Compliance Inspections—progress
05/13/2026Structural Steel - Details—special
05/13/2026Masonry—special
05/13/2026Structural Cold-Formed Steel—special
05/13/2026Final—progress
05/13/2026Footing and Foundation—progress
05/12/2026Final—progress
03/20/2026Ventilation and air distribution system—energy_progress
03/02/2026Post-installed Anchors—special
03/02/2026Heating Systems—special
03/02/2026Fire-Resistant Penetrations and Joints—special
03/02/2026Duct leakage testing, insulation and design—energy_progress
03/02/2026HVAC-R and service water heating system controls—energy_progress
03/02/2026HVAC-R and service water heating equipment—energy_progress
03/02/2026HVAC-R and service water piping design and insulation—energy_progress
03/02/2026Maintenance information—energy_progress
Latest 25 of 43.
▾Documents — 30 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
08/19/2026B01339011-I1Request digital key ↗
08/17/2026B01339002-S2Request digital key ↗
08/15/2026B01339002-I1Request digital key ↗
Showing 3 of 5 on file for this type
▸Zoning, Tax Lot & Property Records2
▸DOB NOWZD1: DOB Zoning Diagram1
08/15/2026B01339002-I1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/15/2026B01339002-I1Open ↗
▸Seals & Professional Certifications8
▸DOB NOWDPL-1: Design Professional Seal & Signature8
09/22/2026B01339002-S4Open ↗
09/22/2026B01339002-S6Open ↗
09/22/2026B01339002-S5Open ↗
Showing 3 of 8 on file for this type
▸Trade Schedules & Equipment1
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)1
08/15/2026B01339002-I1Open ↗
▸Environmental & Asbestos7
▸DOB NOWDEP ACP-5: Asbestos Assessment Report7
09/22/2026B01339002-S4Open ↗
09/22/2026B01339002-S6Open ↗
09/22/2026B01339002-S5Open ↗
Showing 3 of 7 on file for this type
▸Inspections & Test Reports2
▸DOB NOWGeotechnical Report (BC 1803.6)2
09/22/2026B01339002-S6Open ↗
09/22/2026B01339002-S5Open ↗
▸Other Documents5
▸DOB NOWAdjoining Owners Notification2
09/22/2026B01339002-S6Open ↗
09/22/2026B01339002-S5Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/15/2026B01339002-I1Open ↗
▸DOB NOWProperty Ownership Certification1
08/15/2026B01339002-I1Open ↗
▸DOB NOWSite Survey: Initial1
08/15/2026B01339002-I1Open ↗