| Owner | Filings | Most Recent |
|---|---|---|
| J G CONSTRUCTION SRVCS | 4 | 04/09/2026 |
| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 07/11/2024 | $1.9M | — | — → — | $766/sf building |
| 11/07/2013 | $918K | — | Private party → Private party | $370/sf building |
| Firm | Filings | Most Recent |
|---|---|---|
| MARK WEINBERGER ARCHITECT PLLC | 9 | 07/08/2026 |
| STRUCTURAL ENGINEERING TECHNOLOGIES | 1 | 02/05/2026 |
| ASHRAF CORP | 1 | 12/26/2025 |
| Representative | Filings | Most Recent |
|---|---|---|
| EXPEDITER GROUP | 16 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| CLASSIC BUILDERS CORP | General Contractor | 6 | 07/29/2026 |
| WIZ FIRE SPRINKLERS LLC | Fire Protection | 1 | 06/28/2026 |
| J & G CONSTRUCTION SVCS | General Contractor | 1 | 04/09/2026 |
| ORBIT PLBG & HTG INC | Plumbing | 1 | 07/03/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| ENGINEERING CONSULTING SE | 2050 | 7 | 07/08/2026 |
| SHAHRISH SHUVO ENGINEERIN | 8524 | 2 | 02/05/2026 |
| AA BUILDING & INSPECTION | 1519 | 1 | 03/19/2025 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Earth Work | Permit Issued | CLASSIC BUILDERS CORP | 07/28/2026 |
| DOB NOW | Mechanical Systems | Permit Issued | CLASSIC BUILDERS CORP | 07/21/2026 |
| DOB NOW | Sprinklers | Permit Issued | WIZ FIRE SPRINKLERS LLC | 04/27/2026 |
| DOB NOW | Plumbing | Permit Issued | ORBIT PLBG & HTG INC | 03/03/2026 |
| DOB NOW | Sidewalk Shed | Signed-off | J & G CONSTRUCTION SVCS | 12/29/2025 |
| DOB NOW | General Construction | Permit Issued | CLASSIC BUILDERS CORP | 11/06/2025 |
| DOB NOW | Construction Fence | Permit Issued | CLASSIC BUILDERS CORP | 08/05/2025 |
| DOB NOW | General Construction | Permit Issued | CLASSIC BUILDERS CORP | 04/24/2025 |
| DOB NOW | Construction Fence | Permit Issued | CLASSIC BUILDERS CORP | 08/08/2024 |
| BIS | PL | ISSUED | DYCKMAN PLBG & HTG INC | 08/06/2009 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 07/08/2026 | Permit Issued | CLASSIC BUILDERS CORP | Heating and Air Conditioning Systems, Ventilation Systems | Heat / Cool Mitsubishi Electric MXZ-SM48NAMHZ2-U1 48,000 BTU · Heat Pump Outdoor ×2 MXZ-SM60NAM2-U1 60,000 BTU · Heat Pump Outdoor ×1 Ventilation — SP-B80 46 CFM · Exhaust Fan ×6 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 07/08/2026 | Permit Issued | WIZ FIRE SPRINKLERS LLC | Sprinkler System |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 07/08/2026 | Permit Issued | ORBIT PLBG & HTG INC | Gas, Storm, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 05/07/2026 | Permit Issued | B.P. ELECTRIC CORP | 1 meters |
| 12/31/2025 | Complete | RICHARD NEU | — |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 07/08/2026 | Permit Issued | CLASSIC BUILDERS CORP | Steel, Concrete, Masonry |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 12/26/2025 | Signed-off | J & G CONSTRUCTION SVCS | Sidewalk Shed |
| 07/30/2024 | Permit Issued | CLASSIC BUILDERS CORP | Fence |
| Date | Type | Result | Report |
|---|---|---|---|
| 07/21/2026 | Fail-Final PL - Up to 3 Requested Floors | Fail | View ↗ |
| 07/15/2026 | Certified Gas-Gas-Piping-Roughing | Certified | View ↗ |
| 04/30/2026 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 04/29/2026 | Certified Water and Sanitary-WS-Fixtures-Finish | Certified | View ↗ |
| 04/29/2026 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 04/24/2026 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 04/22/2026 | Pass-Final PL - Up to 9 Requested Floors | Pass | View ↗ |
| 03/13/2026 | Certified Storm Drainage-ST-Piping-Underground | Certified | View ↗ |
| 03/13/2026 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| 03/11/2026 | Certified Remove/Cap - work done in accordance with code | Certified | View ↗ |
| 03/04/2026 | Certified Storm Drainage-ST-Piping-Underground | Certified | View ↗ |
| 03/04/2026 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| 06/24/2025 | Certified Storm Drainage-ST-Piping-Roughing | Certified | View ↗ |
| 06/18/2025 | Certified Storm Drainage-ST-Piping-Roughing | Certified | View ↗ |
| 06/18/2025 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 05/27/2025 | Certified Storm Drainage-ST-Piping-Roughing | Certified | View ↗ |
| 05/27/2025 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 08/16/2024 | Certified Storm Drainage-ST-Piping-Underground | Certified | View ↗ |
| 08/16/2024 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| 08/01/2024 | Certified Storm Drainage-ST-Piping-Underground | Certified | View ↗ |
| 08/01/2024 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| 07/23/2024 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 07/01/2026 | Fire-Resistant Penetrations and Joints | PAUL MARINO | special |
| 07/01/2026 | Permanent certificate | PAUL MARINO | energy_progress |
| 07/01/2026 | HVAC-R and service water heating equipment | PAUL MARINO | energy_progress |
| 07/01/2026 | Maintenance information | PAUL MARINO | energy_progress |
| 07/01/2026 | HVAC-R and service water heating system controls | PAUL MARINO | energy_progress |
| 07/01/2026 | HVAC-R and service water piping design and insulation | PAUL MARINO | energy_progress |
| 07/01/2026 | Energy Code Compliance Inspections | PAUL MARINO | progress |
| 05/20/2026 | Fire-Resistant Penetrations and Joints | PAUL MARINO | special |
| 05/20/2026 | Permanent certificate | PAUL MARINO | energy_progress |
| 05/20/2026 | HVAC-R and service water heating equipment | PAUL MARINO | energy_progress |
| 05/20/2026 | Maintenance information | PAUL MARINO | energy_progress |
| 05/20/2026 | HVAC-R and service water heating system controls | PAUL MARINO | energy_progress |
| 05/20/2026 | HVAC-R and service water piping design and insulation | PAUL MARINO | energy_progress |
| 05/20/2026 | Energy Code Compliance Inspections | PAUL MARINO | progress |
| 12/30/2025 | Concrete - Cast-In-Place | Shahrish Shuvo | special |
| 12/30/2025 | Masonry | Shahrish Shuvo | special |
| 12/30/2025 | Structural Steel - High Strength Bolting | Shahrish Shuvo | special |
| 12/30/2025 | Structural Steel - Welding | Shahrish Shuvo | special |
| 12/30/2025 | Post-installed anchors in masonry | Shahrish Shuvo | special |
| 12/08/2025 | Fenestration areas | PAUL MARINO | energy_progress |
| 12/08/2025 | Energy Code Compliance Inspections | PAUL MARINO | progress |
| 12/08/2025 | Fire-Resistant Penetrations and Joints | PAUL MARINO | special |
| 12/08/2025 | Structural Stability – Alterations of existing buildings | PAUL MARINO | special |
| 12/08/2025 | Fire-Resistance Rated Construction | PAUL MARINO | progress |
| 12/08/2025 | Interior lighting power | PAUL MARINO | energy_progress |