← Back
Miscellaneous educational facility
2082 UTICA AVENUE
BROOKLYN · Flatlands · BIN 3336927
💬 Discuss this project
1962Year Built
1Stories
W9Building Class
R3-2Zoning
2,960 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
Miscellaneous educational facility · Owner of record: UTICA BK, LLC · 4,000 sf lot · 0.74 FAR built · Flood zone X
Locations of Work
PlumbingFire Protection
Floor 124p · 2 filings · 11 docs
Site & exterior24p · 2 filings · 11 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
2084 UTICA AVE LLC403/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
12/18/2018$800K—2084 UTICA AVENUE LLC → UTICA RE, LLC$270/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CITY CONSULTANT ENGINEEIRNG PLLC308/12/2020
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
CITY CONSULTANT ENGINEERING603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MASTER FIRE SYSTEMS, INCFire Protection207/08/2026
BMT PLUMBING&HEATING LLCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ADJ ENGINEERING PLLC7640308/12/2020
Building Lifecycle
All (18)Filed (3)Permit Issued (3)Signed Off (2)Violation (6)Objection (2)Special Inspection (2)
07/29/2021
Signed off — Alteration
B00304768-I1
07/29/2021
Signed off — Alteration
Install three (3) backflow preventers for three water service, (1) 1" rpz on existing 1" water service; (2) 1" rpz on existing 1" water service; (3) DCDA on new sprinkler water service as per plan
B00304753-I1
07/14/2021
Permit issued — Sprinklers
B00304768-I1-EW-SP
08/14/2020
Objection resolved — Addressed
08/14/2020
Special inspection requirement — Fire-Resistant Penetrations and Joints
Dwayne Williams
08/13/2020
Objection raised — Other
08/12/2020
Filed — Alteration
Install three (3) backflow preventers for three water service, (1) 1" rpz on existing 1" water service; (2) 1" rpz on existing 1" water service; (3) DCDA on new sprinkler water service as per plan
B00304753-P1
08/12/2020
Special inspection requirement — Fire-Resistant Penetrations and Joints
Dwayne Williams
08/04/2020
Permit issued — Plumbing
B00304753-I1-PL
06/25/2020
Permit issued — Sprinklers
B00304768-I1-EW-SP
03/16/2020
Filed — Alteration
B00304768-I1
03/16/2020
Filed — Alteration
Install three (3) backflow preventers for three water service, (1) 1" rpz on existing 1" water service; (2) 1" rpz on existing 1" water service; (3) DCDA on new sprinkler water service as per plan
B00304753-I1
03/27/2017
Violation issued (ECB, closed)
Construction
03/27/2017
Violation issued (ECB, closed)
Construction
06/10/2016
Violation issued (ECB, closed)
Construction
06/10/2016
Violation issued (ECB, closed)
Construction
08/05/2010
Violation issued (ECB, closed)
Construction
11/12/1991
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSprinklersSigned-offMASTER FIRE SYSTEMS, INC07/14/2021
DOB NOWPlumbingSigned-offBMT PLUMBING&HEATING LLC08/04/2020
DOB NOWSprinklersSigned-offMASTER FIRE SYSTEMS, INC06/25/2020
BIS—ISSUEDGJ'S SUPERIOR RENOVATIONS02/09/2022
BISPLISSUEDBEST PLUMBING PARTNERS11/23/1998
BIS—ISSUEDBOAZ CONTRACTING07/30/1998
BISPLISSUEDRENEW PLUMBING CORP01/30/1992
BIS—ISSUEDT&R CORP T/A BEIT YEHUDAH CENTER12/20/1991
Nothing on file for this building.
▾Special Inspection Requirements (DOB NOW) — 2
DateRequirementInspectorRole
08/14/2020Fire-Resistant Penetrations and JointsDwayne Williamsspecial
08/12/2020Fire-Resistant Penetrations and JointsDwayne Williamsspecial
▾Documents — 48 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch - Plumbing2
09/02/2026B00304753-I1Request digital key ↗
08/15/2026B00304753-P1Request digital key ↗
▸DOB NOWPlans/Sketch - Sprinkler1
09/02/2026B00304768-I1Request digital key ↗
▸Applications & Permits12
▸BISPLAN / WORK APPROVAL APPLICATION10
11/04/2022322089299Open ↗
03/23/2022322089299Open ↗
10/12/2021322089299Open ↗
Showing 3 of 10 on file for this type
▸BISWORK PERMIT APPLICATION1
02/12/2022322089299Open ↗
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION1
02/23/2022322089299Open ↗
▸Zoning, Tax Lot & Property Records3
▸BISADDRESS - NEW HOUSE NUMBER APPROVED1
07/26/2010320190743Open ↗
▸BISVERIFY TAX LOT1
05/20/2022322089299Open ↗
▸BISCO OBJ: VERIFY ADDRESS-TOPO STAMP1
11/02/2022322089299Open ↗
▸Seals & Professional Certifications5
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/13/2026B00304753-I1Open ↗
08/13/2026B00304753-P1Open ↗
08/13/2026B00304768-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
09/02/2026B00304753-P1Open ↗
08/24/2026B00304753-I1Open ↗
▸Trade Schedules & Equipment1
▸BISFINAL PLUMBING SIGNOFF1
08/12/2022322089299Open ↗
▸Safety & Tenant Protection2
▸BISSTREET TREE CHECKLIST2
09/25/2020322089299Open ↗
07/26/2010320190743Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/13/2026B00304753-I1Open ↗
08/13/2026B00304768-I1Open ↗
08/13/2026B00304753-P1Open ↗
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
07/26/2010320190743Open ↗
▸Energy Compliance1
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
09/25/2020322089299Open ↗
▸Inspections & Test Reports1
▸BISTECHNICAL REPORT: RESPONSIBILITY1
09/25/2020322089299Open ↗
▸Approvals, Objections & Sign-offs8
▸BISSCHEDULE A - OCCUPANCY / USE6
09/27/2021322089299Open ↗
09/24/2021322089299Open ↗
08/10/2021322089299Open ↗
Showing 3 of 6 on file for this type
▸BISFINAL ELECTRICAL SIGNOFF1
08/12/2022322089299Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
07/26/2010320190743Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT1
07/26/2010320190743Open ↗
▸BISCOST AFFIDAVIT (FINAL): PW31
05/12/2022322089299Open ↗
▸Filing & Intake Forms4
▸BISADDITIONAL INFORMATION2
04/11/2022322089299Open ↗
09/24/2021322089299Open ↗
▸BISEFILING COVER SHEET2
10/08/2020322089299Open ↗
07/26/2010320190743Open ↗
▸Other Documents2
▸BISPLOT DIAGRAM2
09/27/2021322089299Open ↗
07/26/2010320190743Open ↗