← Back
One family attached or semi-detached
209 ONDERDONK AVENUE
QUEENS · BIN 4081019
💬 Discuss this project
1950Year Built
1Stories
A5Building Class
R5BZoning
898 sfGross Floor Area
1Units
One family attached or semi-detached · 1,980 sf lot · 0.45 FAR built · Flood zone X
Locations of Work
MechanicalPlumbing
Permit Issued — active, not yet Signed-off
RoofUnder Construction12p · 2 filings · 18 docs
Floor 1Under Construction11p · 2 filings · 18 docs
BasementUnder Construction2p · 1 filing · 7 docs
Sub-BasementUnder Construction11p · 2 filings · 18 docs
1 job · most recent 03/11/2022
Air Conditioning Systems Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
03/11/2022Permit IssuedNULITE FUEL OIL CO., LTDAir Conditioning Systems, Heating Systems, Ventilation Systems
Cooling
Carrier 24ACC636A003 36,000 BTU · Condensing Unit ×2
Heating
Carrier CNPVP3617ALA 3 tons ×2
Ventilation
Carrier 58SB0A090E17 88,000 BTU · Furnace ×2
1 job · most recent 03/11/2022
Gas
FiledStatusContractorScope
03/11/2022Permit IssuedNULITE FUEL OIL CO LTDGas
1 job · most recent 12/04/2022
FiledStatusContractorScope
12/04/2022CompleteBERGER QUALITY ELEC'L CON—
Building Lifecycle
All (10)Filed (4)Permit Issued (6)
07/09/2026
Permit issued — Mechanical Systems
Q00589310-I1-MS
07/07/2026
Permit issued — Plumbing
Q00589316-I1-PL
07/08/2025
Permit issued — Plumbing
Q00589316-I1-PL
07/08/2025
Permit issued — Mechanical Systems
Q00589310-I1-MS
03/11/2022
Filed — Alteration
REPLACEMENT OF GAS BOILER WITH GAS FURNACE AS PER PLANS. INSTALL NEW DUCTWORK AND EVAPORATOR COIL AS PER PLANS. INSTALL NEW CONDENSER UNIT ON ROOF AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q00589310-P1
03/11/2022
Filed — Alteration
CONNECT TO EXISTING GAS PIPING FOR REPLACEMENT OF GAS BOILER WITH GAS FURNACE AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q00589316-P1
10/06/2021
Permit issued — Mechanical Systems
Q00589310-I1-MS
10/06/2021
Permit issued — Plumbing
Q00589316-I1-PL
10/01/2021
Filed — Alteration
REPLACEMENT OF GAS BOILER WITH GAS FURNACE AS PER PLANS. INSTALL NEW DUCTWORK AND EVAPORATOR COIL AS PER PLANS. INSTALL NEW CONDENSER UNIT ON ROOF AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q00589310-I1
10/01/2021
Filed — Alteration
CONNECT TO EXISTING GAS PIPING FOR REPLACEMENT OF GAS BOILER WITH GAS FURNACE AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q00589316-I1
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
11/07/2025$1.4M—Private party → Private party$1,559/sf building
08/03/2021$850K—— → —$947/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
BAZINI ENGINEERING, P.C.403/11/2022
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
NULITE FUEL OIL CO., LTDGeneral Contractor307/10/2026
NULITE FUEL OIL CO LTDPlumbing307/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
BAZINI ENGINEERING, P.C.1808403/11/2022
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedNULITE FUEL OIL CO., LTD07/09/2026
DOB NOWPlumbingPermit IssuedNULITE FUEL OIL CO LTD07/07/2026
DOB NOWPlumbingPermit IssuedNULITE FUEL OIL CO LTD07/08/2025
DOB NOWMechanical SystemsPermit IssuedNULITE FUEL OIL CO., LTD07/08/2025
DOB NOWMechanical SystemsPermit IssuedNULITE FUEL OIL CO., LTD10/06/2021
DOB NOWPlumbingPermit IssuedNULITE FUEL OIL CO LTD10/06/2021
BISOTISSUEDSUNPOWER CORPORATION, SYS04/09/2023
BISOTISSUEDSUNPOWER CORPORATION, SYS10/19/2022
▾Special Inspection Requirements (DOB NOW) — 8
DateRequirementInspectorRole
03/11/2022Mechanical SystemsJoseph Bazinispecial
03/11/2022FinalJoseph Baziniprogress
03/11/2022HVAC-R and service water heating equipmentJoseph Bazinienergy_progress
03/11/2022Fire-Resistant Penetrations and JointsJoseph Bazinispecial
12/13/2021Mechanical SystemsJoseph Bazinispecial
12/13/2021FinalJoseph Baziniprogress
12/13/2021HVAC-R and service water heating equipmentJoseph Bazinienergy_progress
12/13/2021Fire-Resistant Penetrations and JointsJoseph Bazinispecial
▾Documents — 48 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/26/2026Q00589310-I1Request digital key ↗
08/26/2026Q00589310-P1Request digital key ↗
08/26/2026Q00589316-I1Request digital key ↗
Showing 3 of 4 on file for this type
▸Applications & Permits3
▸BISPLAN / WORK APPROVAL APPLICATION2
03/01/2023440739499Open ↗
08/21/2022440739499Open ↗
▸BISWORK PERMIT APPLICATION1
10/19/2022440739499Open ↗
▸Seals & Professional Certifications12
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/26/2026Q00589310-I1Open ↗
08/26/2026Q00589316-I1Open ↗
08/13/2026Q00589310-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProgress Inspector Seal & Signature4
08/30/2026Q00589310-P1Open ↗
08/30/2026Q00589310-P1Open ↗
08/24/2026Q00589310-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature2
08/25/2026Q00589316-I1Open ↗
08/24/2026Q00589310-I1Open ↗
▸BISAPPLICANT OWNER SIGNATURE1
08/21/2022440739499Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
08/21/2022440739499Open ↗
▸Safety & Tenant Protection1
▸BISTPP1: TENANT PROTECTION PLAN1
10/19/2022440739499Open ↗
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/26/2026Q00589310-I1Open ↗
08/26/2026Q00589316-I1Open ↗
08/13/2026Q00589316-P1Open ↗
Showing 3 of 4 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
08/21/2022440739499Open ↗
▸Energy Compliance8
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY2
08/19/2024440739499Open ↗
08/21/2022440739499Open ↗
▸BISAIR SEALING AND INSULATION - VISUAL1
10/19/2022440739499Open ↗
▸BISPTA4: SOLAR TAX ABATEMENT APPLICATION (PRELIMINARY)1
08/21/2022440739499Open ↗
▸BISPTA4: SOLAR TAX ABATEMENT APPLICATION (FINAL)1
08/19/2024440739499Open ↗
▸BISAS-BUILT ENERGY ANALYSIS (EN2)1
08/19/2024440739499Open ↗
▸BISENERGY CODE COMPLIANCE INSPECTIONS1
10/19/2022440739499Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
08/21/2022440739499Open ↗
▸Inspections & Test Reports5
▸BISTECHNICAL REPORT: RESPONSIBILITY2
08/19/2024440739499Open ↗
08/21/2022440739499Open ↗
▸BISSTRUCTURAL STABILITY - EXISTING BUILDINGS1
10/19/2022440739499Open ↗
▸BISFIRE-RESISTANT PENETRATIONS AND JOINTS (FIRESTOP)1
10/19/2022440739499Open ↗
▸BISDIR-14 ID OF RESPONSIBILITY (TR1)1
10/19/2022440739499Open ↗
▸Approvals, Objections & Sign-offs2
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
08/21/2024440739499Open ↗
▸BISFINAL1
10/19/2022440739499Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT1
08/21/2022440739499Open ↗
▸BISCOST AFFIDAVIT (FINAL): PW31
08/19/2024440739499Open ↗
▸Filing & Intake Forms5
▸BISADDITIONAL INFORMATION4
03/09/2023440739499Open ↗
10/14/2022440739499Open ↗
10/05/2022440739499Open ↗
Showing 3 of 4 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET1
08/21/2022440739499Open ↗
▸Other Documents1
▸BISTax Abatement Miscellaneous1
08/21/2024440739499Open ↗