← Back
Office with commercial, 1-6 stories
Rutgers Church Campus
2095 BROADWAY · BIN 1030519
💬 Discuss this project
1925Year Built
5Stories
O5Building Class
C4-6AZoning
31,332 sfGross Floor Area
15Units
LL97 Covered19 Open Violations ▸
Office with commercial, 1-6 stories · 5,800 sf lot · 5.4 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanical
Roof3p · 2 filings · 20 docs
Floor 12p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
RUTGERS CHURCH1307/08/2026
RUTGERS PRESBYTERIAN CHURCH3507/08/2026
SAFWAY ATLANTIC LLC503/22/2026
OWNER OF 2093 BROADWAY103/22/2026
RUTGERS PR4ESBITERRIAN CH103/22/2026
ROCK SCAFFOLDING CORP.303/21/2026
MBR CONTRACTING INC103/21/2026
PHOENIX 132 SUTTON STREET203/21/2026
CHASE MANHATTAN BANK203/21/2026
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
CONSTRUCTORS TRADES & SKIGeneral Contractor304/09/2026
GIUSEPPE DI BARTOLOMEOElectrical203/21/2026
SAFWAY ATLANTIC, LLCGeneral Contractor203/21/2026
NATIONAL MAINTENANCEScaffold207/08/2026
LUKASZ TYKAElectrical103/21/2026
RALPH OCCHIPINTIElectrical103/21/2026
SALAZAR, PEDROElectrical103/21/2026
SUGARMAN, IRAElectrical103/21/2026
SYED-NAQVI ALTAFElectrical103/21/2026
SYED-NAQVI, ALTAFElectrical103/21/2026
WALTON, MARCElectrical103/21/2026
HEMNAUTH, SUDESHElectrical103/21/2026
PERFORMANCE MECHANCIALGeneral Contractor107/08/2026
VERICON CONSTRUCTION COGeneral Contractor107/08/2026
HOME RUN ELECTRICElectrical103/22/2026
IRVING BAPTISTEElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
KZ ENGINEERING, P.C.4665109/18/2025
MERRITT ENGINEERING CONSU460109/13/2024
ROHAN ENGINEERING, PC2600304/14/2023
Building Lifecycle
All (118)Filed (11)Permit Issued (10)Signed Off (4)Violation (60)Inspection (1)Objection (2)Special Inspection (30)
09/14/2026
Permit issued — Suspended Scaffold
M01288449-I1-SC
01/20/2026
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
10/24/2025
Permit issued — General Construction
M01162388-I1-GC
10/08/2025
Permit issued — Sidewalk Shed
M01276285-I1-SF
10/08/2025
Permit issued — Supported Scaffold
M01276285-I1-SH
09/30/2025
Filed — Alteration
Installation of temporary heavy duty sidewalk shed and supported scaffold per plan submitted. Work shall comply with 2022 building codes chapter 33. No change in use, egress and/or occupancy with this application.
M01276285-I1
09/30/2025
Permit issued — Suspended Scaffold
M01288449-I1-SC
09/26/2025
Objection resolved — Addressed
09/22/2025
Objection raised — Admin
09/18/2025
Filed — Alteration
Installation of suspended scaffold for facade inspection/ repair.
M01288449-I1
09/16/2025
Special inspection requirement — Alternative Materials - OTCR Buildings Bulletin Number
Karol Zdancewicz
09/16/2025
Special inspection requirement — Post-installed Anchors
Karol Zdancewicz
04/17/2025
Filed — Alteration
Limited facade and exterior repairs as per drawings. No change in use, egress or occupancy is involved under this application.
M01162388-I1
02/03/2025
Signed off — Alteration
Remove the existing ceiling mounted AC unit and ductwork and replace with new Daikin 3 ton VRV-IVS Heat Pump Split System with associated plumbing and electrical. Repair the existing ceiling as needed. No change in use, occupancy or egress.
M01088366-I1
01/24/2025
Filed — Alteration
M01162960-I1
01/03/2025
Special inspection requirement — Final
Martin Griggs
10/09/2024
Permit issued — Mechanical Systems
M01088366-I1-MS
09/13/2024
Filed — Alteration
Remove the existing ceiling mounted AC unit and ductwork and replace with new Daikin 3 ton VRV-IVS Heat Pump Split System with associated plumbing and electrical. Repair the existing ceiling as needed. No change in use, occupancy or egress.
M01088366-I1
07/31/2024
Special inspection requirement — Post-installed Anchors
Christopher Krepcio
07/31/2024
Special inspection requirement — Energy Code Compliance Inspections
Christopher Krepcio
07/30/2024
Special inspection requirement — Final
Christopher Krepcio
07/30/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Christopher Krepcio
07/30/2024
Special inspection requirement — Maintenance information
Christopher Krepcio
07/30/2024
Special inspection requirement — HVAC-R and service water heating system controls
Christopher Krepcio
07/30/2024
Special inspection requirement — Mechanical Systems
Christopher Krepcio
07/30/2024
Special inspection requirement — HVAC-R and service water heating equipment
Christopher Krepcio
05/15/2024
Signed off — Alteration
ERECT ILLUMINATED ACCESSORY BUSINESS WALL SIGN; COPY READING "CHASE WITH LOGO"
M00929944-I1
05/15/2024
Signed off — Alteration
ERECT ILLUMINATED ACCESSORY BUSINESS WALL SIGN; COPY READING "CHASE WITH LOGO"
M00929953-I1
01/11/2024
Permit issued — Sign
M00929953-I1-SG
01/11/2024
Permit issued — Sign
M00929944-I1-SG
01/10/2024
Filed — Alteration
ERECT ILLUMINATED ACCESSORY BUSINESS WALL SIGN; COPY READING "CHASE WITH LOGO"
M00929944-I1
01/10/2024
Filed — Alteration
ERECT ILLUMINATED ACCESSORY BUSINESS WALL SIGN; COPY READING "CHASE WITH LOGO"
M00929953-I1
09/18/2023
Special inspection requirement — Final
AHMED SHAABAN
09/18/2023
Special inspection requirement — Final
AHMED SHAABAN
04/17/2023
Signed off — Alteration
REMOVE EXISTING ROOF TOP COOLING TOWER AND INSTALL ONE (1) 16TON AHU IN CELLAR, TWO (2) 25 TON UNIT IN 2ND FLOOR MEP ROOM, NEW 3 TON UNIT IN SERVER ROOM.
M00503609-I1
04/17/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
BRIAN ROHAN
04/17/2023
Special inspection requirement — HVAC-R and service water heating equipment
Christopher Krepcio
04/17/2023
Special inspection requirement — Maintenance information
Christopher Krepcio
04/17/2023
Special inspection requirement — HVAC-R and service water heating system controls
Christopher Krepcio
04/17/2023
Special inspection requirement — Mechanical Systems
BRIAN ROHAN
04/17/2023
Special inspection requirement — Final
Christopher Krepcio
04/14/2023
Filed — Alteration
REMOVE EXISTING ROOF TOP COOLING TOWER AND INSTALL ONE (1) 16TON AHU IN CELLAR, TWO (2) 25 TON UNIT IN 2ND FLOOR MEP ROOM, NEW 3 TON UNIT IN SERVER ROOM.
M00503609-P2
03/06/2023
Special inspection requirement — Maintenance information
Christopher Krepcio
03/06/2023
Special inspection requirement — HVAC-R and service water heating equipment
Christopher Krepcio
03/06/2023
Special inspection requirement — Final
Christopher Krepcio
03/06/2023
Special inspection requirement — Mechanical Systems
BRIAN ROHAN
03/06/2023
Special inspection requirement — HVAC-R and service water heating system controls
Christopher Krepcio
03/06/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
BRIAN ROHAN
04/14/2022
Filed — Alteration
REMOVE EXISTING ROOF TOP COOLING TOWER AND INSTALL ONE (1) 16TON AHU IN CELLAR, TWO (2) 25 TON UNIT IN 2ND FLOOR MEP ROOM, NEW 3 TON UNIT IN SERVER ROOM.
M00503609-P1
12/17/2021
Special inspection requirement — Maintenance information
Christopher Krepcio
12/17/2021
Special inspection requirement — HVAC-R and service water heating equipment
Christopher Krepcio
12/17/2021
Special inspection requirement — Final
Christopher Krepcio
12/17/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
BRIAN ROHAN
12/17/2021
Special inspection requirement — Mechanical Systems
BRIAN ROHAN
10/21/2021
Permit issued — Supported Scaffold
M00608300-I1-SF
10/18/2021
Filed — Alteration
INSTALLATION OF TEMPORARY SCAFFOLD AS PER DRAWINGS. SCAFFOLD SHALL COMPLY WITH CH #33 OF THE NYC BC. NO CHANGE IN USE, OCCUPANCY OR EGRESS UNDER THIS APPLICATION.
M00608300-I1
08/24/2021
Permit issued — Mechanical Systems
M00503609-I1-MS
05/13/2021
Filed — Alteration
REMOVE EXISTING ROOF TOP COOLING TOWER AND INSTALL ONE (1) 16TON AHU IN CELLAR, TWO (2) 25 TON UNIT IN 2ND FLOOR MEP ROOM, NEW 3 TON UNIT IN SERVER ROOM.
M00503609-I1
07/02/2020
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
07/02/2020
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
Latest 60 of 118 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSuspended ScaffoldPermit IssuedCONSTRUCTORS TRADES & SKI09/14/2026
DOB NOWGeneral ConstructionSigned-offCONSTRUCTORS TRADES & SKI10/24/2025
DOB NOWSidewalk ShedPermit IssuedCONSTRUCTORS TRADES & SKI10/08/2025
DOB NOWSupported ScaffoldPermit IssuedCONSTRUCTORS TRADES & SKI10/08/2025
DOB NOWSuspended ScaffoldPermit IssuedNEW FORCE CONSTR CORP09/30/2025
DOB NOWMechanical SystemsSigned-offPERFORMANCE MECHANCIAL10/09/2024
DOB NOWSignSigned-offNATIONAL MAINTENANCE, INC01/11/2024
DOB NOWSignSigned-offNATIONAL MAINTENANCE, INC01/11/2024
DOB NOWSupported ScaffoldPermit IssuedSAFWAY ATLANTIC, LLC10/21/2021
DOB NOWMechanical SystemsSigned-offVERICON CONSTRUCTION CO08/24/2021
BISMHISSUEDVERICON CONSTRUCTION CO02/21/2019
BISOTISSUEDVERICON CONSTRUCTION CO02/14/2019
BISMHISSUEDSOUND REFRIGERATION & AIR10/19/2017
BISMHISSUEDDONNELLY MECHANICAL CORP11/29/2016
BISOTISSUEDTRADITIONAL WATERPROOFING04/29/2016
BISOTISSUEDINTEGRATED HVAC SYS & SVC01/28/2016
BISOTISSUEDINTEGRATED HVAC SYS & SVC12/07/2015
BISOTISSUEDGREENSULATE LLC10/15/2015
BISOTISSUEDTRADITIONAL WATERPROOFING09/28/2015
BISEQISSUEDPRATT CONSTRUCTION & REST05/12/2015
BISOTISSUEDCENTRAL CONSTRUCTION MANAGEMENT01/22/2015
BISOTISSUEDINTEGRATED HVAC SYS & SVC12/03/2014
BISOTISSUEDINTEGRATED HVAC SYS & SVC11/14/2014
BISOTISSUEDCENTRAL CONSTRUCTION MANAGEMENT01/24/2014
BISEQISSUEDROCK GROUP NY CORP05/17/2013
BISOTISSUEDCENTRAL CONSTRUCTION MANAGEMENT03/06/2013
BISEQISSUEDROCK SCAFFOLDING CORP12/04/2012
BISEQISSUEDMBR CONTRACTING INC05/24/2011
BISEQISSUEDPERIMETER BRIDGE & SCAFFO11/12/2010
BISEQISSUEDPHEONIX 132 SUTTON STREET12/29/2008
BISEQISSUEDPHEONIX 132 SUTTON STREET11/20/2008
BISMHISSUEDPROGRESSIVE CONSTRUCTION INC12/11/2006
BISOTISSUEDPROGRESSIVE CONSTRUCTION INC12/11/2006
BISOTISSUEDJ.A.R. CONSTRUCTION02/01/1999
BIS—ISSUEDLETTERA SGN & ELECTC.INC06/25/1997
BIS—ISSUEDLETTERA SGN & ELECTC.INC06/25/1997
BIS—ISSUEDLETTERA SGN & ELECTC.INC06/25/1997
BISMHRE-ISSUEDMIDTOWN CONTRACTING CORPORATION05/02/1997
BISFBISSUEDA & C COMBUSTION SERVICE CORP.10/29/1992
BISMHISSUEDJOHNSON CONTROLS,INC.04/20/1992
+ 7 more permits on file
6 projects · most recent 10/17/2025
General Wiring
FiledStatusContractorScope
10/17/2025Permit IssuedCENTRUM ELECTRIC CORP—
01/15/2024Permit IssuedHOME RUN ELECTRIC—
01/15/2024Permit IssuedHOME RUN ELECTRIC—
11/07/2022CompleteUNITY ELECTRIC CO. INCGeneral Wiring
03/23/2022Permit IssuedUNITY ELECTRIC CO INCGeneral Wiring
03/08/2019CompleteUNITY ELECTRIC CO INC—
2 projects · most recent 09/30/2025
Scaffold Sidewalk Shed
FiledStatusContractorScope
09/30/2025Permit IssuedCONSTRUCTORS TRADES & SKIScaffold, Sidewalk Shed
10/18/2021Permit IssuedSAFWAY ATLANTIC, LLCScaffold
1 project · most recent 09/18/2025
Suspended Scaffold
FiledStatusContractorScope
09/18/2025Permit IssuedCONSTRUCTORS TRADES & SKISuspended Scaffold
1 project · most recent 09/18/2025
Suspended Scaffold (SC)
FiledStatusContractorScope
09/18/2025Permit IssuedCONSTRUCTORS TRADES & SKISuspended Scaffold (SC)
▾Field Inspections (DOB CAP) — 1
DateTypeResultReport
01/20/2026Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 31
DateRequirementInspectorRole
09/16/2025Alternative Materials - OTCR Buildings Bulletin NumberKarol Zdancewiczspecial
09/16/2025Post-installed AnchorsKarol Zdancewiczspecial
01/03/2025FinalMartin Griggsprogress
07/31/2024Post-installed AnchorsChristopher Krepciospecial
07/31/2024Energy Code Compliance InspectionsChristopher Krepcioprogress
07/30/2024FinalChristopher Krepcioprogress
07/30/2024Fire-Resistant Penetrations and JointsChristopher Krepciospecial
07/30/2024Maintenance informationChristopher Krepcioenergy_progress
07/30/2024HVAC-R and service water heating system controlsChristopher Krepcioenergy_progress
07/30/2024Mechanical SystemsChristopher Krepciospecial
07/30/2024HVAC-R and service water heating equipmentChristopher Krepcioenergy_progress
09/18/2023FinalAHMED SHAABANprogress
09/18/2023FinalAHMED SHAABANprogress
04/17/2023Fire-Resistant Penetrations and JointsBRIAN ROHANspecial
04/17/2023HVAC-R and service water heating equipmentChristopher Krepcioenergy_progress
04/17/2023Maintenance informationChristopher Krepcioenergy_progress
04/17/2023HVAC-R and service water heating system controlsChristopher Krepcioenergy_progress
04/17/2023Mechanical SystemsBRIAN ROHANspecial
04/17/2023FinalChristopher Krepcioprogress
03/06/2023Maintenance informationChristopher Krepcioenergy_progress
03/06/2023HVAC-R and service water heating equipmentChristopher Krepcioenergy_progress
03/06/2023FinalChristopher Krepcioprogress
03/06/2023Mechanical SystemsBRIAN ROHANspecial
03/06/2023HVAC-R and service water heating system controlsChristopher Krepcioenergy_progress
03/06/2023Fire-Resistant Penetrations and JointsBRIAN ROHANspecial
Latest 25 of 31.
▾Tenants in the building
TenantSpaceFloorsRenovation projects
ChaseOfficeCellar, Floor 2, Roof
Project M00503609 Alteration · LOC Issued · 05/13/2021
Read from each project’s drawing title blocks and cover sheets and checked twice; a name appears only when it is the occupant, never the owner, landlord or designer.
▾Documents — 268 on file (BIS + DOB NOW)
▸Plans & Drawings11
▸DOB NOWPlans/Sketch11
09/03/2026M00608300-I1Request digital key ↗
09/02/2026M00503609-P1Request digital key ↗
09/02/2026M00503609-P2Request digital key ↗
Showing 3 of 11 on file for this type
▸Applications & Permits52
▸BISPLAN / WORK APPROVAL APPLICATION29
11/15/2018123600969Open ↗
01/31/2018122607973Open ↗
01/31/2018122936859Open ↗
Showing 3 of 29 on file for this type
▸BISWORK PERMIT APPLICATION23
02/21/2019123600969Open ↗
02/15/2019123600969Open ↗
12/06/2016122607973Open ↗
Showing 3 of 23 on file for this type
▸Seals & Professional Certifications90
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION35
05/09/2019123600969Open ↗
11/15/2018123600969Open ↗
11/27/2017140528105Open ↗
Showing 3 of 35 on file for this type
▸DOB NOWProgress Inspector Seal & Signature17
09/19/2026M01162388-I1Open ↗
08/28/2026M01088366-I1Open ↗
08/28/2026M01088366-I1Open ↗
Showing 3 of 17 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature10
09/02/2026M00503609-P2Open ↗
09/02/2026M00503609-I1Open ↗
09/02/2026M00503609-P1Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature9
08/31/2026M01288449-I1Open ↗
08/31/2026M01288449-I1Open ↗
08/28/2026M01088366-I1Open ↗
Showing 3 of 9 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST7
10/08/2015122508223Open ↗
05/06/2015122371815Open ↗
12/06/2012121450839Open ↗
Showing 3 of 7 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM6
12/06/2012121450839Open ↗
05/25/2011120699707Open ↗
11/19/2010120530489Open ↗
Showing 3 of 6 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT4
11/23/2016122607973Open ↗
09/08/2016140528105Open ↗
10/08/2015122508223Open ↗
Showing 3 of 4 on file for this type
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
09/08/2016140528105Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
09/08/2016140528105Open ↗
▸Trade Schedules & Equipment6
▸BISEQUIPMENT USE APPLICATION/PERMIT5
05/08/2019123600969Open ↗
05/08/2019123600969Open ↗
05/08/2019123600969Open ↗
Showing 3 of 5 on file for this type
▸BISEQUIPMENT USE PERMITS1
11/27/2017140528105Open ↗
▸Environmental & Asbestos14
▸BISASBESTOS: CERTIFICATION (DEP ACP5)6
11/15/2018123600969Open ↗
11/23/2016122607973Open ↗
11/14/2016122936859Open ↗
Showing 3 of 6 on file for this type
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER4
05/25/2011120699707Open ↗
11/19/2010120530489Open ↗
Showing 2 of 4 on file for this type
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/28/2026M00929953-I1Open ↗
08/24/2026M01162388-I1Open ↗
08/13/2026M00929944-I1Open ↗
Showing 3 of 4 on file for this type
▸Energy Compliance21
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS11
05/09/2019123600969Open ↗
11/15/2018123600969Open ↗
11/27/2017140528105Open ↗
Showing 3 of 11 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS6
05/09/2019123600969Open ↗
11/27/2017140528105Open ↗
06/20/2017122153864Open ↗
Showing 3 of 6 on file for this type
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
09/08/2016140528105Open ↗
▸BISTR8: Energy Code Progress Inspections1
10/10/2014122153864Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
09/08/2016140528105Open ↗
▸DOB NOWEN2: As Built Energy Analysis.1
09/02/2026M00503609-I1Open ↗
▸Inspections & Test Reports1
▸BISTECHNICAL REPORT: RESPONSIBILITY1
09/08/2016140528105Open ↗
▸Approvals, Objections & Sign-offs22
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST9
05/09/2019123600969Open ↗
11/27/2017140528105Open ↗
06/20/2017122153864Open ↗
Showing 3 of 9 on file for this type
▸BISADMINISTRATIVE OBJECTIONS6
12/06/2012121450839Open ↗
08/25/2012121344535Open ↗
05/25/2011120699707Open ↗
Showing 3 of 6 on file for this type
▸BISLETTERS - SUPPORTING DOCUMENTATION4
05/09/2019123600969Open ↗
11/27/2017140528105Open ↗
01/19/2016121450839Open ↗
Showing 3 of 4 on file for this type
▸BISSUPERSEDING LETTER1
05/20/2013121450839Open ↗
▸BISSHED LETTER1
05/20/2013121450839Open ↗
▸DOB NOWDEP Variance (V5) letter1
09/02/2026M00503609-I1Open ↗
▸Cost, Insurance & Ownership21
▸BISCOST AFFIDAVIT20
05/09/2019123600969Open ↗
11/15/2018123600969Open ↗
11/27/2017140528105Open ↗
Showing 3 of 20 on file for this type
▸BISCIVIL PENALTY AFFADAVIT/REQUEST1
10/12/2016140528105Open ↗
▸Filing & Intake Forms28
▸BISEFILING COVER SHEET11
11/15/2018123600969Open ↗
11/18/2016122607973Open ↗
11/14/2016122936859Open ↗
Showing 3 of 11 on file for this type
▸BISADDITIONAL INFORMATION10
10/19/2017140528105Open ↗
03/10/2017122508223Open ↗
02/24/2017122153864Open ↗
Showing 3 of 10 on file for this type
▸BISBOROUGH INTAKE FORM4
05/09/2019123600969Open ↗
01/31/2018122607973Open ↗
01/31/2018122936859Open ↗
Showing 3 of 4 on file for this type
▸BISeFiling Job Application Cover Sheet3
09/08/2016140528105Open ↗
Showing 1 of 3 on file for this type
▸Other Documents2
▸DOB NOWManufacturer's Specifications1
08/13/2026M01288449-I1Open ↗
▸DOB NOWCalculations1
08/13/2026M01288449-I1Open ↗