ECB10/05/2026Failure to comply with commissioner's order to file a certificate of correction. At time of inspection, no certificate of correction on file for class 1 violation #39105643H issued 02/08/2024 for obstructed egr$1K due
ECB08/12/2026Failure to secure public safety and/or make the buildings's structure and appurtenances conform to the provisions of the administrative code. As noted at time of inspection on an active occupied parking structu$25K due
ECB04/23/2026Failure to secure public safety and/or make the bldg's structure and appurtenances conform to the provision of the admin code after unsafe notification filed by qpsi. Note: at time of inspection on an active pa$10K due
ECB11/10/2025Failure to secure safety and/or make the bldng's structure and appurtenances conform to the provision of the admin code after unsafe notification filed by qpsi. Note: at time of inspection on an active parking$25K due
DOB08/26/2024Emergency work order:7 levels (grnd,abv grnd,rooftop)with vehicles occupied.spalled/crack concrete slba/beam/wall exposed rebar, rusted rebar, various locations at levels 1-7 without safety measures install as req per code.remedy:owner retain nys reg des.pro to evaluate,superv direct progress report to parkingstuctures@buildings.NYC.gov
DOB11/15/2023Install approximately 50 feel of sidewalk shed along the expo#2 wall by the north east corner of the building the sidewalk shed shall be installed tigh back to the building on exp#2, provide protection for entry door and walkway, & run southward from the expo#2 and #3 cornerIssued 2023; DOB's record still lists it as active
ECB02/08/2024Obstructed egress: at stairwell a the 2ND,3RD,and 6TH floor exit doors are obstructed by wooden cleats and concrete nails at time of inspection, remove obstruction; remove obstructionNothing owed — awaiting certificate of correction
ECB11/30/2023At garage #4 defective emerg. Lights at various location throughout premises. Also, at 7FLR. Observed spalling concrete w. Exposed rebar on parapet wall near stair-c/exp.2, the up & down ramps, spalling concretNothing owed — awaiting certificate of correction
ECB11/30/2023Observed at garage #5, defective emerg. Lights at various location throughout the 7-stories. Also, observed broken bricks, broken nubio glass panels, spalling concrete with exposed rebar at various locations thNothing owed — awaiting certificate of correction
ECB08/24/2023Failure to maintain building in a code compliant manner. I observed spalling concrete and exposed rebar throughout the parking garage #7. The conditions are in the floor and roof from the 1ST floor to the roof,Nothing owed — awaiting certificate of correction
ECB04/30/2018Failure to file a final inspection for completed work within 1YR of permit expiration.premises under pc ALT2#220234306 which expired 06/26/14 application filed for build-out of new medical office to include parNothing owed — awaiting certificate of correction
ECB10/31/2009Failure to maintain bldg in code complaint manner. Use of prohibited door and/or hardware per bc 1008.1.8;27-37.j noted @ roof level exits doors leading to stairwells open against the flow of egress. Total doorNothing owed — awaiting certificate of correction
ECB10/31/2009Failure to maintain bldg in code complaint manner. Highrise to provideexit sign requirement within exit per bc 1011.1.1 27-383.1 noted at 1FL 4 exits leading to stairwell leading to exits to exterior no exit siNothing owed — awaiting certificate of correction
ECB10/31/2009Failure to mantain bldg in code complaint manner. Highrise to provide exit sign requirements with in exits per bc 1011.1.1;237-383.1 noted at 1ST fl exit that lead to stairwell to exit leading to exterior no exNothing owed — awaiting certificate of correction
ECB10/31/2009Failure to maintain bldg in code complaint manner. Lack of emergency lighting for exits, exit dischargesand public corridors per bc 1006.1-27-542 noted at 2ND level northeast & northwest stairwells and ramp froNothing owed — awaiting certificate of correction