← Back
Miscellaneous two family
21-44 CLINTONVILLE STREET
QUEENS · Whitestone-Beechhurst · BIN 4109895
💬 Discuss this project
1960Year Built
2Stories
B9Building Class
R3-1Zoning
2,601 sfGross Floor Area
2Units
0 Open Violations
Miscellaneous two family · 1,870 sf lot · 1.39 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbingGeneral
Cellar2p · 2 filings · 6 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
12/26/2023$1.2M—Private party → Private party$450/sf building
11/13/2013$780K—— → —$300/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
JX FLAME SOLUTION INC204/25/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
DY EXPEDITING403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
HOMEPRO GENERAL CONTRACTINGGeneral Contractor303/21/2026
GOODALL ELECTRIC CORPElectrical103/22/2026
WATERWORKS PLUMBING MECHPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
JX FLAME SOLUTION INC7286104/25/2023
Building Lifecycle
All (16)Filed (2)Permit Issued (2)Signed Off (2)Violation (3)Inspection (7)
09/21/2023
Signed off — Alteration
PROPOSED PLUMBING WORK ON CELLAR FLOOR OF AN EXIST 2 FAMILY BUILDING. PLUMBING WORK TYPE IS IN CONJUNCTION WITH DOB NOW APPLICATION # Q00861309. NO CHANGE IN USE, EGRESS AND OCCUPANCY.
Q00861310-I1
09/14/2023
Signed off — Alteration
Q00861309-I1
08/29/2023
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
08/21/2023
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
08/15/2023
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
08/09/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
08/09/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
08/04/2023
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
08/03/2023
Inspection — No Access-Final PL - Up to 3 Requested Floors
No Access
View inspection ↗
07/07/2023
Violation issued (ECB, closed)
Construction
06/27/2023
Permit issued — Plumbing
Q00861310-I1-PL
06/23/2023
Permit issued — General Construction
Q00861309-I1-GC
04/25/2023
Filed — Alteration
PROPOSED PLUMBING WORK ON CELLAR FLOOR OF AN EXIST 2 FAMILY BUILDING. PLUMBING WORK TYPE IS IN CONJUNCTION WITH DOB NOW APPLICATION # Q00861309. NO CHANGE IN USE, EGRESS AND OCCUPANCY.
Q00861310-I1
04/25/2023
Filed — Alteration
Q00861309-I1
11/30/2017
Violation issued (ECB, closed)
Quality of Life
11/30/2017
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offWATERWORKS PLUMBING MECH06/27/2023
DOB NOWGeneral ConstructionSigned-offHOMEPRO GENERAL CONTRACTI06/23/2023
2 projects · most recent 07/14/2023
General Wiring
FiledStatusContractorScope
07/14/2023CompleteGOODALL ELECTRIC CORPGeneral Wiring
07/14/2023CompleteGOODALL ELECTRIC CORPGeneral Wiring
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
08/29/2023Pass-Final General Construction Non-Directive 14PassView ↗
08/21/2023Fail-Final General Construction Non-Directive 14FailView ↗
08/15/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
08/09/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
08/09/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
08/04/2023Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
08/03/2023No Access-Final PL - Up to 3 Requested FloorsNo AccessView ↗
▾Documents — 23 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/24/2026Q00861309-I1Request digital key ↗
08/24/2026Q00861310-I1Request digital key ↗
▸Applications & Permits3
▸BISPLAN / WORK APPROVAL APPLICATION3
11/24/2023440488919Open ↗
09/11/2018440488919Open ↗
06/13/2018440488919Open ↗
▸Zoning, Tax Lot & Property Records1
▸BISEASEMENT AND RESTRICTIVE DECLARATIONS - SUPPPORTING DOCUMENTATION1
09/11/2018440488919Open ↗
▸Seals & Professional Certifications5
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/24/2026Q00861309-I1Open ↗
08/13/2026Q00861310-I1Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
06/13/2018440488919Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
06/13/2018440488919Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
06/13/2018440488919Open ↗
▸Trade Schedules & Equipment2
▸BISSCHEDULE B - PLUMBING1
06/13/2018440488919Open ↗
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE1
09/11/2018440488919Open ↗
▸Safety & Tenant Protection1
▸BISTENANT PROTECTION PLAN AND NOTES1
06/13/2018440488919Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/24/2026Q00861309-I1Open ↗
08/13/2026Q00861310-I1Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
06/13/2018440488919Open ↗
▸Energy Compliance2
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
06/13/2018440488919Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
06/13/2018440488919Open ↗
▸Inspections & Test Reports1
▸BISTECHNICAL REPORT: RESPONSIBILITY1
06/13/2018440488919Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
06/13/2018440488919Open ↗
▸Filing & Intake Forms2
▸BISEFILING JOB APPLICATION COVER SHEET1
06/13/2018440488919Open ↗
▸BISBOROUGH INTAKE FORM1
09/11/2018440488919Open ↗