← Back
One family attached or semi-detached
21-45 38 STREET
QUEENS · BIN 4015934
💬 Discuss this project
1925Year Built
2Stories
A5Building Class
R5BZoning
1,335 sfGross Floor Area
1Units
Rent Stabilized0 Open Violations
One family attached or semi-detached · 2,000 sf lot · 0.67 FAR built · Flood zone X
Locations of Work
Plumbing
Cellar2p · 1 filing · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
06/06/2019$987K—Private party → Private party$739/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ADS&Y INC.411/26/2020
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
BYPASS MECHANICAL CORPPlumbing207/08/2026
Building Lifecycle
All (38)Filed (4)Permit Issued (2)Signed Off (1)Violation (5)Objection (14)Special Inspection (12)
04/12/2021
Signed off — Alteration
AT CELLAR: REPLACE BURNER TO CONVERT FUEL FROM OIL TO NATURAL GAS, REPLACE HWH, REMOVE WASHER AND CAP LINES AT ONE LOCATION AND INSTALL NEW WASHER AT ANOTHER LOCATION, INSTALL DRYER AND SLOP SINK, REMOVE OIL TANK, REPLACE GAS METER.
Q00197258-I1
12/10/2020
Special inspection requirement — HVAC and service water heating equipment
SIDERIS CARAMINTZOS
12/10/2020
Special inspection requirement — Maintenance information
SIDERIS CARAMINTZOS
12/10/2020
Special inspection requirement — Energy Code Compliance Inspections
SIDERIS CARAMINTZOS
12/07/2020
Objection resolved — Addressed
12/02/2020
Objection raised — Admin
11/26/2020
Filed — Alteration
AT CELLAR: REPLACE BURNER TO CONVERT FUEL FROM OIL TO NATURAL GAS, REPLACE HWH, REMOVE WASHER AND CAP LINES AT ONE LOCATION AND INSTALL NEW WASHER AT ANOTHER LOCATION, INSTALL DRYER AND SLOP SINK, REMOVE OIL TANK, REPLACE GAS METER.
Q00197258-P4
11/24/2020
Special inspection requirement — Energy Code Compliance Inspections
SIDERIS CARAMINTZOS
11/24/2020
Special inspection requirement — HVAC and service water heating equipment
SIDERIS CARAMINTZOS
11/24/2020
Special inspection requirement — Maintenance information
SIDERIS CARAMINTZOS
10/16/2020
Objection resolved — Addressed
10/07/2020
Objection raised — Scope
10/01/2020
Filed — Alteration
AT CELLAR: REPLACE BURNER TO CONVERT FUEL FROM OIL TO NATURAL GAS, REPLACE HWH, REMOVE WASHER AND CAP LINES AT ONE LOCATION AND INSTALL NEW WASHER AT ANOTHER LOCATION, INSTALL DRYER AND SLOP SINK, REMOVE OIL TANK, REPLACE GAS METER.
Q00197258-P3
09/30/2020
Special inspection requirement — HVAC and service water heating equipment
SIDERIS CARAMINTZOS
09/30/2020
Special inspection requirement — Maintenance information
SIDERIS CARAMINTZOS
09/30/2020
Special inspection requirement — Energy Code Compliance Inspections
SIDERIS CARAMINTZOS
09/02/2020
Permit issued — Plumbing
Q00197258-I1-PL
08/28/2020
Objection resolved — Addressed
08/17/2020
Special inspection requirement — HVAC and service water heating equipment
SIDERIS CARAMINTZOS
08/17/2020
Special inspection requirement — Maintenance information
SIDERIS CARAMINTZOS
08/14/2020
Objection raised — Scope
08/10/2020
Filed — Alteration
AT CELLAR: REPLACE BURNER TO CONVERT FUEL FROM OIL TO NATURAL GAS, REPLACE HWH, REMOVE WASHER AND CAP LINES AT ONE LOCATION AND INSTALL NEW WASHER AT ANOTHER LOCATION, INSTALL DRYER AND SLOP SINK, REMOVE OIL TANK, REPLACE GAS METER.
Q00197258-P1
07/26/2020
Special inspection requirement — Energy Code Compliance Inspections
SIDERIS CARAMINTZOS
11/07/2019
Violation issued (HPD, closed)
I
10/24/2019
Permit issued — Plumbing
Q00197258-I1-PL
08/23/2019
Objection raised — Admin
08/23/2019
Objection resolved — Addressed
08/23/2019
Objection raised — Scope
08/23/2019
Objection resolved — Addressed
08/23/2019
Objection raised — Inspections
08/23/2019
Objection resolved — Addressed
08/23/2019
Objection raised — Scope
08/23/2019
Objection resolved — Addressed
08/20/2019
Filed — Alteration
AT CELLAR: REPLACE BURNER TO CONVERT FUEL FROM OIL TO NATURAL GAS, REPLACE HWH, REMOVE WASHER AND CAP LINES AT ONE LOCATION AND INSTALL NEW WASHER AT ANOTHER LOCATION, INSTALL DRYER AND SLOP SINK, REMOVE OIL TANK, REPLACE GAS METER.
Q00197258-I1
01/07/2005
Violation issued (HPD, closed)
B
10/15/2004
Violation issued (HPD, closed)
B
10/15/2004
Violation issued (HPD, closed)
B
10/15/2004
Violation issued (HPD, closed)
B
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offBYPASS MECHANICAL CORP09/02/2020
DOB NOWPlumbingSigned-offBYPASS MECHANICAL CORP10/24/2019
BISOTISSUEDLOCATI DELEVLOPMENT INC10/10/2019
BISPLISSUEDMASTER PLUMBER11/13/1996
BIS—ISSUEDJOE CONTRACTING CO.10/10/1996
Nothing on file for this building.
▾Special Inspection Requirements (DOB NOW) — 12
DateRequirementInspectorRole
12/10/2020HVAC and service water heating equipment SIDERIS CARAMINTZOSenergy_progress
12/10/2020Maintenance informationSIDERIS CARAMINTZOSenergy_progress
12/10/2020Energy Code Compliance InspectionsSIDERIS CARAMINTZOSprogress
11/24/2020Energy Code Compliance InspectionsSIDERIS CARAMINTZOSprogress
11/24/2020HVAC and service water heating equipment SIDERIS CARAMINTZOSenergy_progress
11/24/2020Maintenance informationSIDERIS CARAMINTZOSenergy_progress
09/30/2020HVAC and service water heating equipment SIDERIS CARAMINTZOSenergy_progress
09/30/2020Maintenance informationSIDERIS CARAMINTZOSenergy_progress
09/30/2020Energy Code Compliance InspectionsSIDERIS CARAMINTZOSprogress
08/17/2020HVAC and service water heating equipment SIDERIS CARAMINTZOSenergy_progress
08/17/2020Maintenance informationSIDERIS CARAMINTZOSenergy_progress
07/26/2020Energy Code Compliance InspectionsSIDERIS CARAMINTZOSprogress
▾Documents — 38 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch - Plumbing4
08/15/2026Q00197258-P3Request digital key ↗
08/15/2026Q00197258-P4Request digital key ↗
08/14/2026Q00197258-P1Request digital key ↗
Showing 3 of 4 on file for this type
▸Applications & Permits2
▸BISWORK PERMIT APPLICATION1
10/15/2019421794044Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION1
08/22/2019421794044Open ↗
▸Seals & Professional Certifications17
▸DOB NOWProgress Inspector Seal & Signature12
08/28/2026Q00197258-P3Open ↗
08/28/2026Q00197258-P3Open ↗
08/28/2026Q00197258-P3Open ↗
Showing 3 of 12 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/28/2026Q00197258-I1Open ↗
08/13/2026Q00197258-P3Open ↗
08/13/2026Q00197258-P1Open ↗
Showing 3 of 4 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
10/15/2019421794044Open ↗
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/14/2026Q00197258-I1Open ↗
08/13/2026Q00197258-P1Open ↗
08/13/2026Q00197258-P4Open ↗
Showing 3 of 4 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
08/22/2019421794044Open ↗
▸Energy Compliance2
▸BISAS-BUILT ENERGY ANALYSIS1
04/20/2021421794044Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
10/15/2019421794044Open ↗
▸Inspections & Test Reports1
▸BISTECHNICAL REPORT: RESPONSIBILITY1
04/20/2021421794044Open ↗
▸Approvals, Objections & Sign-offs1
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
04/20/2021421794044Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
04/20/2021421794044Open ↗
08/22/2019421794044Open ↗
▸Filing & Intake Forms4
▸BISADDITIONAL INFORMATION3
08/28/2020421794044Open ↗
08/10/2020421794044Open ↗
09/19/2019421794044Open ↗
▸BISEFILING COVER SHEET1
08/22/2019421794044Open ↗