← Back
Over six families without stores
21-66 CRESCENT STREET
QUEENS · Astoria (North)-Ditmars-Steinway · BIN 4019009
💬 Discuss this project
1928Year Built
4Stories
C1Building Class
R5DZoning
20,400 sfGross Floor Area
32Units
Rent Stabilized1 Open Violation ▸
Over six families without stores · Owner of record: ARIS CRESCENT II LLC · 8,645 sf lot · 2.36 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
ARIS INVESTMENT MANAGEMENT703/22/2026
ARIS CRESCENT II LLC103/22/2026
OWNER OF 21-70 CRESCENT S103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
JUNG H. CHOI, ARCHITECT, PC101/17/2025
NEW YORK ENGINEERING ASSOC., P.C.109/09/2020
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
NEW YORK ENGINEERING ASSOCIATES P C203/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NEW YORK ENGINEERING ASSO851109/09/2020
Building Lifecycle
All (26)Filed (2)Permit Issued (1)Signed Off (1)Violation (17)Objection (1)Special Inspection (4)
01/09/2026
Violation issued (HPD, closed)
C
01/09/2026
Violation issued (HPD, open)
C
01/09/2026
Violation issued (HPD, closed)
C
01/30/2025
Objection raised — Fire_Protection
01/17/2025
Filed — Alteration
INTERIOR RENOVATION WORK, CONVERTING UNIT C1 INTO TWO BEDROOM UNIT AND UNIT C2 INTO STUDIO UNIT. REMOVAL OF NON-LOAD BEARING WALLS AND PARTITIONS AND INSTALLATION OF NEW GYP.BRD.WALL AS PER PLAN. THERE IS NO CHANGE IN USE, MEANS OF EGRESS, OR OCCUPANCY.
Q01144101-I1
11/18/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
11/18/2024
Special inspection requirement — Tenant Protection Plan Compliance
11/18/2024
Special inspection requirement — Final
11/18/2024
Special inspection requirement — Fire-Resistance Rated Construction
05/07/2024
Violation issued (HPD, closed)
C
11/24/2023
Violation issued (HPD, closed)
I
10/24/2022
Violation issued (HPD, closed)
A
08/18/2021
Violation issued (HPD, closed)
C
08/18/2021
Violation issued (HPD, closed)
C
08/09/2021
Violation issued (HPD, closed)
C
08/09/2021
Violation issued (HPD, closed)
C
04/14/2021
Violation issued (HPD, closed)
A
11/02/2020
Signed off — Alteration
Q00386151-I1
09/10/2020
Permit issued — Boiler Equipment
Q00386151-I1-BE
09/09/2020
Filed — Alteration
Q00386151-I1
02/24/2017
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/20/2013
Violation issued (HPD, closed)
C
03/20/2013
Violation issued (HPD, closed)
B
03/20/2013
Violation issued (HPD, closed)
B
01/19/2007
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
07/19/2000
Violation issued (ECB, closed)
Boilers
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWBoiler EquipmentSigned-offNEW YORK HEATING CORP09/10/2020
BISEQISSUEDARSENAL SCAFFOLD INC04/18/2007
BISEQISSUEDARSENAL SCAFFOLD INC11/16/2006
Nothing on file for this building.
▾Special Inspection Requirements (DOB NOW) — 4
DateRequirementInspectorRole
11/18/2024Fire-Resistant Penetrations and Joints—special
11/18/2024Tenant Protection Plan Compliance—special
11/18/2024Final—progress
11/18/2024Fire-Resistance Rated Construction—progress
▾Documents — 7 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch1
08/21/2026Q01144101-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Boiler Equipment1
08/28/2026Q00386151-I1Request digital key ↗
▸Seals & Professional Certifications2
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/28/2026Q00386151-I1Open ↗
08/21/2026Q01144101-I1Open ↗
▸Safety & Tenant Protection1
▸DOB NOWTenant Protection Plan1
08/13/2026Q00386151-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/28/2026Q00386151-I1Open ↗
08/21/2026Q01144101-I1Open ↗