← Back
Church, synagogue, chapel
Immaculate Conception Catholic Acad
21-81 29 STREET · BIN 4437018
💬 Discuss this project
1951Year Built
3Stories
M1Building Class
R6AZoning
63,909 sfGross Floor Area
1Units
LL97 Covered1 Open Violation 0 unresolved · 1 paperwork only ▸FDNY Report ↗
Church, synagogue, chapel · 57,315 sf lot · 1.12 FAR built · Flood zone X
Locations of Work
MechanicalPlumbingFire Protection
Permit Issued — active, not yet Signed-off
RoofUnder Construction1 filing · 6 docs
Floor 211p · 1 filing · 10 docs
Floor 112p · 1 filing · 10 docs
CellarUnder Construction13p · 2 filings · 16 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
ROCKLYN ASSET2808/28/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NEW AGE ENGINEERING PLLC108/25/2026
VAA209/29/2022
NEW YORK ENGINEERING ASSOC., P.C.505/27/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
NEW YORK ENGINEERING903/21/2026
VAA203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
BONDEE ENTERPRISES INCPlumbing207/08/2026
JD MASTERS P & H, INCFire Protection107/08/2026
AMERICAN VENTILATION SERVGeneral Contractor107/08/2026
GUARANTEED HOME IMPROVEMEGeneral Contractor108/27/2026
JD MASTERS PLBG & HTGPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NEW AGE ENGINEERING PLLC7746108/25/2026
C.M. TESTING LABORATORY,1352209/29/2022
NEW YORK ENGINEERING ASSO851505/27/2021
Building Lifecycle
All (46)Filed (8)Permit Issued (6)Signed Off (3)Violation (14)Inspection (2)Special Inspection (13)
08/26/2026
Permit issued — Mechanical Systems
Q01446630-I1-MS
08/25/2026
Filed — Alteration
INSTALL NEW CHIMNEY LINER AS PER PLANS. NO CHANGE TO USE, OCCUPANCY OR EGRESS.
Q01446630-I1
08/25/2026
Special inspection requirement — Chimneys and vents
Stephen Shishko
08/17/2026
Special inspection requirement — Final
Stephen Shishko
08/17/2026
Special inspection requirement — Mechanical Systems
Stephen Shishko
06/30/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/30/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/29/2022
Filed — Alteration
Propose to install sprinkler system and plumbing fixtures all as per plans filed herewith. no change in use egress or occupancy is proposed under this application.
Q00202830-P1
05/03/2022
Signed off — Alteration
REPLACE GAS PIPING AND INSTALL NEW GAS METER IN CELLAR OFF EXISTING GAS SERVICE.
Q00509181-I1
03/09/2022
Signed off — Alteration
REPLACE GAS BOILER.
Q00509163-I1
07/23/2021
Signed off — Alteration
Q00515693-I1
07/09/2021
Inspection — Pass-Final Boiler Equipment Inspection
Pass
View inspection ↗
06/24/2021
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
06/11/2021
Permit issued — Mechanical Systems
Q00515693-I1-MS
06/01/2021
Special inspection requirement — Heating Systems
LOUIS ARENA
06/01/2021
Special inspection requirement — HVAC-R and service water heating system controls
LOUIS ARENA
06/01/2021
Special inspection requirement — Maintenance information
LOUIS ARENA
06/01/2021
Special inspection requirement — HVAC-R and service water heating equipment
LOUIS ARENA
05/27/2021
Filed — Alteration
REPLACE GAS PIPING AND INSTALL NEW GAS METER IN CELLAR OFF EXISTING GAS SERVICE.
Q00509181-P1
05/25/2021
Filed — Alteration
REPLACE GAS BOILER.
Q00509163-P1
05/19/2021
Special inspection requirement — Maintenance information
LOUIS ARENA
05/19/2021
Special inspection requirement — HVAC-R and service water heating equipment
LOUIS ARENA
05/19/2021
Special inspection requirement — HVAC-R and service water heating system controls
LOUIS ARENA
05/19/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
LOUIS ARENA
05/19/2021
Special inspection requirement — Energy Code Compliance Inspections
LOUIS ARENA
05/19/2021
Special inspection requirement — Heating Systems
LOUIS ARENA
05/14/2021
Filed — Alteration
Q00515693-I1
05/11/2021
Permit issued — Plumbing
Q00509181-I1-PL
05/10/2021
Permit issued — Boiler Equipment
Q00509163-I1-BE
05/04/2021
Filed — Alteration
REPLACE GAS BOILER.
Q00509163-I1
05/03/2021
Filed — Alteration
REPLACE GAS PIPING AND INSTALL NEW GAS METER IN CELLAR OFF EXISTING GAS SERVICE.
Q00509181-I1
10/01/2020
Violation issued (ECB, open)
Construction
03/02/2020
Permit issued — Sprinklers
Q00202830-I1-PL
03/02/2020
Permit issued — Plumbing
Q00202830-I1-EW-SP
02/14/2020
Filed — Alteration
Propose to install sprinkler system and plumbing fixtures all as per plans filed herewith. no change in use egress or occupancy is proposed under this application.
Q00202830-I1
11/08/2019
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
04/06/2018
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
12/31/2009
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/06/2006
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/19/2003
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/26/2002
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/27/2001
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/27/2001
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/07/2000
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/07/2000
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/28/1993
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedGUARANTEED HOME IMPROVEME08/26/2026
DOB NOWMechanical SystemsSigned-offAMERICAN VENTILATION SERV06/11/2021
DOB NOWPlumbingSigned-offBONDEE ENTERPRISES INC05/11/2021
DOB NOWBoiler EquipmentSigned-offBONDEE ENTERPRISES INC05/10/2021
DOB NOWSprinklersPermit IssuedJD MASTERS PLBG & HTG03/02/2020
DOB NOWPlumbingPermit IssuedJD MASTERS P & H, INC03/02/2020
BIS—ISSUEDFPS CONTRACTING INC02/24/2021
BISOTISSUEDFPS CONTRACTING INC02/24/2021
BIS—ISSUEDFPS CONTRACTING INC11/19/2020
BISOTISSUEDFPS CONTRACTING INC03/02/2020
BISOTISSUEDFPS CONTRACTING INC09/06/2019
1 project · most recent 08/25/2026
Others
FiledStatusContractorScopeMake / Model / Capacity
08/25/2026Permit IssuedGUARANTEED HOME IMPROVEMEOthers
Other
Lifetime Chimney Supply XUL 1 BTU · Chimney ×1
1 project · most recent 09/29/2022
FiledStatusContractorScope
09/29/2022Permit IssuedJD MASTERS P & H, INC—
1 project · most recent 09/29/2022
Water/Sanitary
FiledStatusContractorScope
09/29/2022Permit IssuedJ.D. MASTERS PLBG & HTGWater/Sanitary
2 projects · most recent 05/17/2021
General Wiring
FiledStatusContractorScope
05/17/2021Permit IssuedPJZ MAINTENANCE CORP.General Wiring
02/07/2020CompleteSALVATORE CAMPISI & SONSGeneral Wiring
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
07/09/2021Pass-Final Boiler Equipment InspectionPassView ↗
06/24/2021Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 13
DateRequirementInspectorRole
08/25/2026Chimneys and ventsStephen Shishkospecial
08/17/2026FinalStephen Shishkoprogress
08/17/2026Mechanical SystemsStephen Shishkospecial
06/01/2021Heating SystemsLOUIS ARENAspecial
06/01/2021HVAC-R and service water heating system controlsLOUIS ARENAenergy_progress
06/01/2021Maintenance informationLOUIS ARENAenergy_progress
06/01/2021HVAC-R and service water heating equipmentLOUIS ARENAenergy_progress
05/19/2021Maintenance informationLOUIS ARENAenergy_progress
05/19/2021HVAC-R and service water heating equipmentLOUIS ARENAenergy_progress
05/19/2021HVAC-R and service water heating system controlsLOUIS ARENAenergy_progress
05/19/2021Fire-Resistant Penetrations and JointsLOUIS ARENAspecial
05/19/2021Energy Code Compliance InspectionsLOUIS ARENAprogress
05/19/2021Heating SystemsLOUIS ARENAspecial
▾Documents — 88 on file (BIS + DOB NOW)
▸Plans & Drawings10
▸DOB NOWPlans/Sketch6
08/27/2026Q00515693-I1Request digital key ↗
08/27/2026Q00509163-P1Request digital key ↗
08/27/2026Q00509163-I1Request digital key ↗
Showing 3 of 6 on file for this type
▸DOB NOWPlans/Sketch - Sprinkler2
08/25/2026Q00202830-I1Request digital key ↗
08/15/2026Q00202830-P1Request digital key ↗
▸DOB NOWPlans/Sketch - Plumbing2
08/25/2026Q00202830-P1Request digital key ↗
08/25/2026Q00202830-I1Request digital key ↗
▸Applications & Permits9
▸BISPLAN / WORK APPROVAL APPLICATION5
06/04/2021421942349Open ↗
05/05/2021421942349Open ↗
11/09/2020421942349Open ↗
Showing 3 of 5 on file for this type
▸BISWORK PERMIT APPLICATION3
11/19/2020421942349Open ↗
03/05/2020421797755Open ↗
09/09/2019421797755Open ↗
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION1
11/23/2020421942349Open ↗
▸Seals & Professional Certifications25
▸DOB NOWProgress Inspector Seal & Signature8
09/23/2026Q01446630-I1Open ↗
09/23/2026Q00509163-I1Open ↗
09/23/2026Q00509163-I1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature8
08/27/2026Q00515693-I1Open ↗
08/27/2026Q00509163-I1Open ↗
08/27/2026Q00509163-P1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
09/23/2026Q00509163-I1Open ↗
09/23/2026Q01446630-I1Open ↗
08/26/2026Q00509163-P1Open ↗
Showing 3 of 4 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION3
12/06/2019421942349Open ↗
12/06/2019421942349Open ↗
09/09/2019421797755Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
09/09/2019421797755Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
09/09/2019421797755Open ↗
▸Safety & Tenant Protection4
▸BISSTREET TREE CHECKLIST3
11/19/2020421942349Open ↗
12/06/2019421942349Open ↗
12/06/2019421942349Open ↗
▸BISTenant Protection Plan and Notes1
09/09/2019421797755Open ↗
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form4
08/27/2026Q00515693-I1Open ↗
08/27/2026Q00509163-I1Open ↗
08/25/2026Q00202830-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/26/2026Q01446630-I1Open ↗
▸Energy Compliance5
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS3
12/06/2019421942349Open ↗
12/06/2019421942349Open ↗
09/09/2019421797755Open ↗
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026Q00509163-I1Open ↗
▸DOB NOWPreliminary Commissioning Report Certification1
08/13/2026Q00509163-I1Open ↗
▸Approvals, Objections & Sign-offs15
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter8
08/27/2026Q00515693-I1Open ↗
08/27/2026Q00509181-I1Open ↗
08/26/2026Q01446630-I1Open ↗
Showing 3 of 8 on file for this type
▸BISSCHEDULE A - OCCUPANCY / USE4
06/04/2021421942349Open ↗
05/05/2021421942349Open ↗
11/09/2020421942349Open ↗
Showing 3 of 4 on file for this type
▸BISLETTERS - SUPPORTING DOCUMENTATION3
12/06/2019421942349Open ↗
12/06/2019421942349Open ↗
09/09/2019421797755Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
12/06/2019421942349Open ↗
09/09/2019421797755Open ↗
▸Filing & Intake Forms2
▸BISEFILING COVER SHEET2
12/06/2019421942349Open ↗
09/09/2019421797755Open ↗
▸Other Documents11
▸BISCONSTRUCTION - SUPPORTING DOCUMENTATION9
11/10/2020421942349Open ↗
11/10/2020421942349Open ↗
11/10/2020421942349Open ↗
Showing 3 of 9 on file for this type
▸BISPLOT DIAGRAM2
12/06/2019421942349Open ↗
12/06/2019421942349Open ↗