← Back
BuildNYC
Two family brick
21 SOUTH ELLIOTT PLACE
BROOKLYN · Fort Greene · BIN 3058798
💬 Discuss this project
1870Year Built
3Stories
B1Building Class
R6BZoning
3,620 sfGross Floor Area
2Units
Rent Stabilized0 Active ViolationsFDNY Report ↗
Two family brick · 2,000 sf lot · 1.81 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire Protection
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
RoofPlace Alteration43p · 1 filing · 20 docs
Floor 3Place Alteration41p · 1 filing · 20 docs
Floor 2Place Alteration42p · 1 filing · 20 docs
Floor 1Place Alteration44p · 1 filing · 20 docs
CellarPlace Alteration45p · 1 filing · 20 docs
BasementPlace Alteration40p · 1 filing · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
03/05/2021$3.1M—Private party → Private party$856/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Celmer Architecture1308/02/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Commercial Capital USA1603/21/2026
BMB Building Consulting1003/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Black Square BuildersGeneral Contractor1207/08/2026
Orbit Plumbing & HeatingPlumbing507/08/2026
Orbit SprinklerPlumbing103/22/2026
Orbit SprinklerFire Protection107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SD Testing & Inspection S70101008/02/2023
Building Lifecycle
06/10/2025
(a) § hmc:file annual bedbug report in accordance with HPD rule as described on the back of this notice of violation or as described on HPDs…
HPD violation · closed
11/27/2024
§27-2107 ADM code owner failed to file a valid registration statement with the department as required by ADM code §27-2097 and is therefore subject…
HPD violation · closed
04/11/2024
(a) § hmc:file annual bedbug report in accordance with HPD rule as described on the back of this notice of violation or as described on HPDs…
HPD violation · closed
01/01/2024
Permit expired, never signed off — General Construction
The city's record still shows this permit as issued, with no sign-off on its filing
B00536952-I1-GC
11/20/2023
§27-2107 ADM code owner failed to file a valid registration statement with the department as required by ADM code §27-2097 and is therefore subject…
HPD violation · closed
73 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedBlack Square Builders02/09/2023
DOB NOWPlumbingSigned-offOrbit Plumbing & Heating11/09/2022
DOB NOWMechanical SystemsSigned-offBlack Square Builders05/20/2022
DOB NOWStructuralSigned-offBlack Square Builders05/20/2022
DOB NOWGeneral ConstructionPermit IssuedBlack Square Builders01/06/2022
DOB NOWPlumbingSigned-offOrbit Plumbing & Heating11/16/2021
DOB NOWSprinklersSigned-offOrbit Sprinkler11/16/2021
DOB NOWGeneral ConstructionPermit IssuedBlack Square Builders10/07/2021
DOB NOWFoundationSigned-offBlack Square Builders10/05/2021
DOB NOWStructuralSigned-offBlack Square Builders10/05/2021
DOB NOWMechanical SystemsSigned-offBlack Square Builders10/05/2021
BISPLISSUEDJohn Hkad PLG & Heating03/25/1994
BIS—ISSUEDDorf Construction01/20/1994
1 project · most recent 08/02/2023
Heating Systems Ventilation Systems
FiledStatusContractorScope
08/02/2023Permit IssuedBlack Square BuildersHeating Systems, Ventilation Systems
1 project · most recent 08/02/2023
Gas Storm Water/Sanitary
FiledStatusContractorScope
08/02/2023Signed-offOrbit Plumbing & HeatingGas, Storm, Water/Sanitary
1 project · most recent 03/22/2022
General Wiring
FiledStatusContractorScope
03/22/2022CompleteFried Electric CoGeneral Wiring
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
03/03/2023Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
03/01/2023Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
03/01/2023Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
04/01/2022Certified Gas-Gas-Piping-RoughingCertifiedView ↗
03/25/2022Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 48
DateRequirementInspectorRole
09/07/2023FinalXIUCHENG LIprogress
09/07/2023Mechanical SystemsXIUCHENG LIspecial
05/15/2023Mechanical SystemsXIUCHENG LIspecial
05/15/2023FinalXIUCHENG LIprogress
05/25/2022Energy Code Compliance InspectionsXIUCHENG LIprogress
05/25/2022Fenestration air leakageXIUCHENG LIenergy_progress
05/25/2022Fenestration and door U-factor and product ratingsXIUCHENG LIenergy_progress
05/25/2022MeteringXIUCHENG LIenergy_progress
05/25/2022Maintenance informationXIUCHENG LIenergy_progress
05/25/2022Interior lighting powerXIUCHENG LIenergy_progress
05/25/2022Air barrier - visual inspectionXIUCHENG LIenergy_progress
05/25/2022Lighting controlsXIUCHENG LIenergy_progress
05/25/2022Fenestration areasXIUCHENG LIenergy_progress
05/25/2022Insulation placement and R valuesXIUCHENG LIenergy_progress
05/25/2022Lighting in dwelling unitsXIUCHENG LIenergy_progress
05/25/2022Structural Stability – Alterations of existing buildingsXIUCHENG LIspecial
05/25/2022PreliminaryXIUCHENG LIprogress
05/25/2022Fire-Resistant Penetrations and JointsXIUCHENG LIspecial
05/25/2022Fire-Resistance Rated ConstructionXIUCHENG LIprogress
02/22/2022Sprinkler SystemsXIUCHENG LIspecial
02/22/2022Fire-Resistant Penetrations and JointsXIUCHENG LIspecial
02/22/2022Post-installed AnchorsXIUCHENG LIspecial
02/09/2022Fire-Resistant Penetrations and JointsXIUCHENG LIspecial
02/09/2022Post-installed AnchorsXIUCHENG LIspecial
02/09/2022Sprinkler SystemsXIUCHENG LIspecial
Latest 25 of 48.
74 filed documents on file for this building. Sign in free to see the full history. Sign in · Create account