| Owner | Filings | Most Recent |
|---|---|---|
| BRAUSE REALTY | 86 | 07/08/2026 |
| HENDRICKS HOTEL LLC | 5 | 03/22/2026 |
| 38 REALTY CO C/O BRAUSE REALTY | 95 | 03/22/2026 |
| OWNER OF 21-23 W 38 ST | 3 | 03/22/2026 |
| 38 REALTY CO C O BRAUSE REALTY | 109 | 03/21/2026 |
| 38 VANDERBILT | 2 | 03/21/2026 |
| BRAUSE REALTY INC AS AGENT FOR 3 | 3 | 03/21/2026 |
| Firm | Filings | Most Recent |
|---|---|---|
| JACK GREEN ASSOCIATES | 7 | 12/19/2025 |
| DPM ARCHITECTURE, P.C. | 2 | 09/02/2025 |
| SURFACE DESIGN | 2 | 09/13/2023 |
| AVCON ENGINEERING PC | 2 | 02/17/2023 |
| LOFFREDO BROOKS ARCHITECTS P.C. | 1 | 02/17/2023 |
| CONAPAC SERVICES, DBA | 1 | 02/03/2023 |
| NYMS CONSULTING, LLC | 1 | 09/02/2022 |
| VINCENT J. LIOTTA P.E. | 3 | 05/18/2022 |
| GTA ARCHITECTURE, PLLC | 2 | 01/12/2022 |
| Representative | Filings | Most Recent |
|---|---|---|
| RETHY ASSOCIATES | 28 | 03/21/2026 |
| VINCENT J. LIOTTA P.E. | 2 | 03/21/2026 |
| MUNICIPAL BUILDING CONSULTANTS | 2 | 03/21/2026 |
| VINCENT J. LIOTTA P. E. | 2 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| MOREAIR MECHANICAL SERVIC | General Contractor | 10 | 07/08/2026 |
| CMA PLUMBING & HEATING IN | Fire Protection | 5 | 07/08/2026 |
| 5 K CONSTRUCTION GROUP | General Contractor | 4 | 07/08/2026 |
| I.M.P. PLBG. & HTG. CORP | Plumbing | 3 | 07/08/2026 |
| D.B.J. CONTRACTING CORP | General Contractor | 3 | 07/08/2026 |
| REMI INTERIORS INC | General Contractor | 3 | 03/21/2026 |
| JER ELECTRIC CORP | Electrical | 2 | 03/22/2026 |
| COLGATE RESTORATION CORP | General Contractor | 2 | 03/21/2026 |
| JANSONS ASSOICATES, INC | General Contractor | 2 | 03/21/2026 |
| WALTON, MARC | Electrical | 1 | 03/21/2026 |
| CORBETT, RICHARD | Electrical | 1 | 03/21/2026 |
| CONTRACTING BY REJI INC | Electrical | 1 | 03/21/2026 |
| 5 K CONSTRUCTION RESOURCE | General Contractor | 1 | 04/09/2026 |
| EASTERN ELEC'L TECHNOLOGI | Electrical | 1 | 03/22/2026 |
| ALPHONSE, MICHAEL | Electrical | 1 | 03/21/2026 |
| HEMNAUTH, SUDESH | Electrical | 1 | 03/21/2026 |
| KINGS GROUP NY CORP | General Contractor | 1 | 07/08/2026 |
| CALIK, MURAT | Electrical | 1 | 03/21/2026 |
| JOHN CORBETT | Electrical | 1 | 03/21/2026 |
| PEREIRA, WESLLEY | Electrical | 1 | 03/21/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| JACK GREEN ASSOCIATES | 422 | 10 | 12/19/2025 |
| SURFACE DESIGN PROFESSION | 3968 | 2 | 09/13/2023 |
| HRF SERVICES CORP | 5616 | 1 | 09/02/2022 |
| VINCENT J. LIOTTA P. E. | 1974 | 3 | 05/18/2022 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Mechanical Systems | Signed-off | MOREAIR MECHANICAL SERVIC | 12/22/2025 |
| DOB NOW | General Construction | Signed-off | 5 K CONSTRUCTION RESOURCE | 09/04/2025 |
| DOB NOW | Mechanical Systems | Permit Issued | MOREAIR MECHANICAL SERVIC | 12/15/2023 |
| DOB NOW | Plumbing | Signed-off | CMA PLUMBING & HEATING IN | 11/08/2023 |
| DOB NOW | Sprinklers | Signed-off | I.M.P. PLBG. & HTG. CORP | 09/11/2023 |
| DOB NOW | Sprinklers | Signed-off | CMA PLUMBING & HEATING IN | 09/07/2023 |
| DOB NOW | General Construction | Permit Issued | REMI INTERIORS INC | 07/15/2023 |
| DOB NOW | General Construction | Signed-off | COLGATE RESTORATION CORP | 03/23/2023 |
| DOB NOW | Sprinklers | Signed-off | I.M.P. PLBG. & HTG. CORP | 03/08/2023 |
| DOB NOW | Mechanical Systems | Signed-off | MOREAIR MECHANICAL SERVIC | 03/02/2023 |
| DOB NOW | General Construction | Signed-off | 5 K CONSTRUCTION GROUP | 03/01/2023 |
| DOB NOW | Plumbing | Signed-off | CMA PLUMBING & HEATING IN | 03/01/2023 |
| DOB NOW | Sidewalk Shed | Signed-off | KINGS GROUP NY CORP | 02/03/2023 |
| DOB NOW | Mechanical Systems | Permit Issued | JANSONS ASSOICATES, INC | 09/19/2022 |
| DOB NOW | Mechanical Systems | Signed-off | MOREAIR MECHANICAL SERVIC | 05/19/2022 |
| DOB NOW | Sprinklers | Permit Issued | CMA PLUMBING & HEATING IN | 05/04/2022 |
| DOB NOW | Mechanical Systems | Permit Issued | MOREAIR MECHANICAL SERVIC | 03/23/2022 |
| DOB NOW | General Construction | Permit Issued | 5 K CONSTRUCTION GROUP | 02/24/2022 |
| DOB NOW | Mechanical Systems | Signed-off | MOREAIR MECHANICAL SERVIC | 09/09/2021 |
| DOB NOW | Mechanical Systems | Permit Issued | DBJ CONTRACTING | 11/05/2020 |
| DOB NOW | Mechanical Systems | Signed-off | MOREAIR MECHANICAL SERVIC | 09/28/2020 |
| DOB NOW | Mechanical Systems | Permit Issued | DBJ CONTRACTING | 09/03/2020 |
| DOB NOW | Mechanical Systems | Signed-off | MOREAIR MECHANICAL SERVIC | 08/28/2020 |
| DOB NOW | Plumbing | Permit Issued | CMA PLUMBING & HEATING IN | 08/21/2020 |
| DOB NOW | Plumbing | Signed-off | I.M.P. PLBG. & HTG. CORP | 08/21/2020 |
| BIS | OT | ISSUED | 5 K CONSTRUCTION GROUP | 05/03/2022 |
| BIS | OT | ISSUED | D.B.J. CONTRACTING CORP | 06/29/2021 |
| BIS | OT | ISSUED | D.B.J. CONTRACTING CORP | 11/10/2020 |
| BIS | OT | ISSUED | D.B.J. CONTRACTING CORP | 08/22/2020 |
| BIS | SP | ISSUED | CMA PLUMBING & HEATING IN | 10/22/2019 |
| BIS | EQ | ISSUED | S&E BRIDGE & SCAFFOLD LLC. | 11/07/2018 |
| BIS | OT | ISSUED | D.B.J. CONTRACTING CORP | 07/11/2018 |
| BIS | OT | ISSUED | SKYLINE RESTORATION INC | 03/08/2018 |
| BIS | OT | ISSUED | SKYLINE RESTORATION INC | 02/06/2018 |
| BIS | OT | ISSUED | PAV-LAK CONTRACTING INC | 01/29/2018 |
| BIS | OT | ISSUED | PAV-LAK CONTRACTING INC | 01/09/2018 |
| BIS | OT | ISSUED | CG 1982 CORP | 11/21/2017 |
| BIS | EQ | ISSUED | SPRING SCAFFOLDING LLC | 11/20/2017 |
| BIS | EQ | ISSUED | S&E BRIDGE & SCAFFOLD LLC. | 11/14/2017 |
| BIS | FP | ISSUED | ACTIVE FIRE CONTROL, INC | 10/17/2017 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 12/19/2025 | Signed-off | MOREAIR MECHANICAL SERVIC | Air Conditioning Systems | Cooling Mitsubishi Electric # PEFY-P72NMHSU-E 3 tons · Vrf Indoor ×2 MXZ-SM120TAM 7,345 CFM · Condensing Unit ×1 |
| 09/20/2024 | Permit Issued | MOREAIR MECHANICAL SERVIC | Air Conditioning Systems | Cooling York DSV120C2S5HAA1A00-A 4,000 CFM · Ahu ×10 |
| 05/23/2023 | Permit Issued | MOREAIR MECHANICAL SERVIC | Air Conditioning Systems | Cooling Sigma # SDSV-C.2-120-2-C-1-DS-H 120,000 BTU · Wshp ×1 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 08/07/2020 | Permit Issued | CMA PLUMBING & HEATING IN | 294 heads |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 08/07/2020 | Signed-off | I.M.P. PLBG. & HTG. CORP | Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 12/01/2023 | Permit Issued | JER ELECTRIC CORP | General Wiring, Lighting |
| 06/13/2023 | Complete | NEW PHASE ELEC'L CONTR'S | General Wiring |
| 03/22/2023 | Permit Issued | HIGH QUALITY ELECTRIC OF | — |
| 08/19/2022 | Complete | JER ELECTRIC CORP | General Wiring, Lighting |
| 05/12/2021 | Permit Issued | STAR ELEC'L CONTRACTORS C | — |
| 08/18/2020 | Complete | JER ELECTRIC CORP | General Wiring, Lighting |
| 11/08/2019 | Complete | EASTERN ELEC'L TECHNOLOGI | General Wiring |
| 04/17/2018 | Complete | TRIZA ELECTRICAL CORP | General Wiring |
| Date | Type | Result | Report |
|---|---|---|---|
| 04/01/2024 | Certified Sprinkler-SP-Fixtures-Finish | Certified | View ↗ |
| 03/28/2024 | Certified Remove/Cap - work done in accordance with code | Certified | View ↗ |
| 03/28/2024 | Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test | Certified | View ↗ |
| 12/22/2023 | Certified Water and Sanitary-WS-Fixtures-Finish | Certified | View ↗ |
| 09/25/2023 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 08/03/2023 | Certified Sprinkler-SP-Fixtures-Finish | Certified | View ↗ |
| 07/31/2023 | Certified Remove/Cap - work done in accordance with code | Certified | View ↗ |
| 07/31/2023 | Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test | Certified | View ↗ |
| 07/20/2023 | Certified Remove/Cap - work done in accordance with code | Certified | View ↗ |
| 07/19/2023 | Certified Water and Sanitary-WS-Fixtures-Finish | Certified | View ↗ |
| 04/19/2023 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 12/05/2025 | Shutoff dampers | LAWRENCE GREEN | energy_progress |
| 12/05/2025 | Fire-Resistant Penetrations and Joints | LAWRENCE GREEN | special |
| 12/05/2025 | Energy Code Compliance Inspections | LAWRENCE GREEN | progress |
| 12/05/2025 | HVAC-R and service water piping design and insulation | LAWRENCE GREEN | energy_progress |
| 12/05/2025 | HVAC-R and service water heating system controls | LAWRENCE GREEN | energy_progress |
| 12/05/2025 | Maintenance information | LAWRENCE GREEN | energy_progress |
| 12/05/2025 | HVAC-R and service water heating equipment | LAWRENCE GREEN | energy_progress |
| 11/10/2025 | Mechanical Systems | LAWRENCE GREEN | special |
| 11/10/2025 | Final | LAWRENCE GREEN | progress |
| 08/22/2025 | Final | LAWRENCE GREEN | progress |
| 09/20/2024 | HVAC and service water heating system controls | JACK GREEN | energy_progress |
| 09/20/2024 | HVAC insulation and sealing | JACK GREEN | energy_progress |
| 09/20/2024 | Shutoff dampers | JACK GREEN | energy_progress |
| 09/20/2024 | HVAC and service water heating equipment | JACK GREEN | energy_progress |
| 09/20/2024 | Maintenance information | JACK GREEN | energy_progress |
| 09/20/2024 | Energy Code Compliance Inspections | JACK GREEN | progress |
| 09/20/2024 | Final | JACK GREEN | progress |
| 09/20/2024 | Fire-Resistant Penetrations and Joints | JACK GREEN | special |
| 09/20/2024 | Mechanical Systems | JACK GREEN | special |
| 08/30/2023 | Post-installed Anchors | MOLLY FORR | special |
| 08/30/2023 | Air barrier - visual inspection | Benson Gillespie | energy_progress |
| 08/30/2023 | Final | Benson Gillespie | progress |
| 08/30/2023 | Energy Code Compliance Inspections | Benson Gillespie | progress |
| 08/30/2023 | Masonry | MOLLY FORR | special |
| 05/17/2023 | Fire-Resistant Penetrations and Joints | JACK GREEN | special |
| Tenant | Space | Floors | Renovation projects |
|---|---|---|---|
| Miller Samuel | Office | Floor 15 | Project M00827550 |