← Back
Two family brick
2106 61 STREET
BROOKLYN · BIN 3132651
💬 Discuss this project
1930Year Built
2Stories
B1Building Class
R5Zoning
2,720 sfGross Floor Area
2Units
2 Open Violations ▸FDNY Report ↗
Two family brick · 2,500 sf lot · 1.09 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralPlumbing
Permit Issued — active, not yet Signed-off
Roof3p · 1 filing · 7 docs
Floor 3Under Construction12p · 2 filings · 16 docs
Floor 2Under Construction14p · 2 filings · 16 docs
Floor 1Under Construction14p · 2 filings · 16 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
02/15/2024$1.9M—— → —$680/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
JACOB WESEL104/10/2026
J DESIGN AND CONSULTANTS LLC403/18/2026
PRAMODRAY SHAH, P.E.302/18/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
NYC PERMIT SERVICES403/21/2026
IZHAK KLAR103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
YAFE MEOD CORPGeneral Contractor604/09/2026
B36 SERVICES INCGeneral Contractor107/08/2026
KISHAN PLUMBING INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SHAHRISH SHUVO ENGINEERIN8524110/31/2024
Building Lifecycle
All (36)Filed (8)Permit Issued (6)Violation (4)Inspection (5)Special Inspection (13)
06/04/2026
Violation issued (ECB, open)
Signs
04/10/2026
Filed — Alteration
Plumbing worktype
B01337256-P3
03/26/2026
Permit issued — Construction Fence
B01182396-I1-FN
03/18/2026
Filed — Alteration
Plumbing worktype
B01337256-P2
03/18/2026
Special inspection requirement — Energy Code Compliance Inspections
Jacob Wesel
03/18/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Jacob Wesel
03/12/2026
Permit issued — Plumbing
B01337256-I1-PL
03/06/2026
Violation issued (ECB, closed)
Construction
02/23/2026
Filed — Alteration
Plumbing worktype
B01337256-P1
02/23/2026
Special inspection requirement — Energy Code Compliance Inspections
Jacob Wesel
02/23/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Jacob Wesel
02/13/2026
Filed — Alteration
Plumbing worktype
B01337256-S1
12/19/2025
Filed — Alteration
Plumbing worktype
B01337256-I1
10/31/2025
Violation issued (ECB, open)
Construction
10/31/2025
Inspection — Certified Storm Drainage-ST-Fixtures-Finish
Certified
View inspection ↗
10/31/2025
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
03/28/2025
Permit issued — General Construction
B01076270-I1-GC
03/28/2025
Permit issued — Structural
B01076270-S1-ST
03/06/2025
Permit issued — Construction Fence
B01182396-I1-FN
02/18/2025
Filed — Alteration
Installing 8 feet high construction fence
B01182396-I1
10/31/2024
Filed — Alteration
Interior renovation worktype. No change to occupancy, egress or bulk.
B01076270-S1
10/29/2024
Special inspection requirement — Structural Steel - Details
Shahrish Shuvo
10/29/2024
Special inspection requirement — Structural Steel - High Strength Bolting
Shahrish Shuvo
10/29/2024
Special inspection requirement — Structural Steel - Welding
Shahrish Shuvo
10/29/2024
Special inspection requirement — Final
Shahrish Shuvo
10/29/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
Shahrish Shuvo
10/29/2024
Special inspection requirement — Masonry
Shahrish Shuvo
10/29/2024
Special inspection requirement — Post-installed Anchors
Shahrish Shuvo
10/29/2024
Special inspection requirement — Structural Cold-Formed Steel
Shahrish Shuvo
07/29/2024
Permit issued — General Construction
B01076270-I1-GC
07/10/2024
Filed — Alteration
Interior renovation worktype. No change to occupancy, egress or bulk.
B01076270-I1
07/03/2024
Special inspection requirement — Final
PRAMODRAY SHAH
06/24/2024
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
06/24/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
02/09/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
10/27/2021
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWConstruction FencePermit IssuedYAFE MEOD CORP03/26/2026
DOB NOWPlumbingPermit IssuedN AND S PLUMBING INC03/12/2026
DOB NOWGeneral ConstructionPermit IssuedYAFE MEOD CORP03/28/2025
DOB NOWStructuralPermit IssuedYAFE MEOD CORP03/28/2025
DOB NOWConstruction FencePermit IssuedYAFE MEOD CORP03/06/2025
DOB NOWGeneral ConstructionPermit IssuedB36 SERVICES INC07/29/2024
1 project · most recent 04/10/2026
Water/Sanitary
FiledStatusContractorScope
04/10/2026Permit IssuedKISHAN PLUMBING INCWater/Sanitary
1 project · most recent 10/31/2024
Steel Masonry
FiledStatusContractorScope
10/31/2024Permit IssuedYAFE MEOD CORPSteel, Masonry
1 project · most recent 02/18/2025
Fence
FiledStatusContractorScope
02/18/2025Permit IssuedYAFE MEOD CORPFence
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
10/31/2025Certified Storm Drainage-ST-Fixtures-FinishCertifiedView ↗
10/31/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
06/24/2024Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
06/24/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
02/09/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 13
DateRequirementInspectorRole
03/18/2026Energy Code Compliance InspectionsJacob Weselprogress
03/18/2026HVAC-R and service water piping design and insulationJacob Weselenergy_progress
02/23/2026Energy Code Compliance InspectionsJacob Weselprogress
02/23/2026HVAC-R and service water piping design and insulationJacob Weselenergy_progress
10/29/2024Structural Steel - DetailsShahrish Shuvospecial
10/29/2024Structural Steel - High Strength BoltingShahrish Shuvospecial
10/29/2024Structural Steel - WeldingShahrish Shuvospecial
10/29/2024FinalShahrish Shuvoprogress
10/29/2024Structural Stability – Alterations of existing buildingsShahrish Shuvospecial
10/29/2024MasonryShahrish Shuvospecial
10/29/2024Post-installed AnchorsShahrish Shuvospecial
10/29/2024Structural Cold-Formed SteelShahrish Shuvospecial
07/03/2024FinalPRAMODRAY SHAHprogress
▾Documents — 18 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch6
08/23/2026B01076270-S1Request digital key ↗
08/23/2026B01076270-I1Request digital key ↗
08/22/2026B01182396-I1Request digital key ↗
Showing 3 of 6 on file for this type
▸Seals & Professional Certifications12
▸DOB NOWDPL-1: Design Professional Seal & Signature6
08/23/2026B01076270-S1Open ↗
08/23/2026B01076270-I1Open ↗
08/18/2026B01337256-P2Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWProgress Inspector Seal & Signature5
09/01/2026B01076270-I1Open ↗
09/01/2026B01337256-P2Open ↗
09/01/2026B01337256-P2Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature1
08/25/2026B01076270-S1Open ↗