← Back
Walk-up apt, over six families with stores
2108 CHATTERTON AVENUE
BRONX · Castle Hill-Unionport · BIN 2026285
💬 Discuss this project
1927Year Built
3Stories
C7Building Class
R5Zoning
11,907 sfGross Floor Area
18Units
Rent Stabilized8 Open Violations ▸FDNY Report ↗
Walk-up apt, over six families with stores · Owner of record: 2108 CHATTERTON LLC · 4,430 sf lot · 2.69 FAR built · Flood zone X
Locations of Work
MechanicalPlumbing
Cellar1p · 2 filings · 11 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
664 REALTY807/08/2026
2108 CHATTERTON LLC403/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ANDREW KATZ ENGINEERS201/20/2020
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
B&B MECH PLBG & HTG LLCPlumbing207/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
DAVID KATZ, P.E.6087101/20/2020
Building Lifecycle
All (71)Filed (2)Permit Issued (2)Signed Off (2)Violation (60)Objection (2)Special Inspection (3)
01/06/2025
Violation issued (HPD, closed)
C
06/12/2024
Violation issued (HPD, open)
C
06/12/2024
Violation issued (HPD, closed)
B
01/21/2024
Violation issued (HPD, closed)
C
01/21/2024
Violation issued (HPD, closed)
C
01/13/2024
Violation issued (HPD, open)
C
03/28/2023
Violation issued (HPD, closed)
C
03/28/2023
Violation issued (HPD, closed)
C
11/16/2022
Violation issued (HPD, closed)
C
11/16/2022
Violation issued (HPD, closed)
B
11/16/2022
Violation issued (HPD, closed)
B
11/16/2022
Violation issued (HPD, closed)
A
10/13/2022
Violation issued (HPD, closed)
C
10/13/2022
Violation issued (HPD, closed)
C
10/13/2022
Violation issued (HPD, open)
B
10/13/2022
Violation issued (HPD, closed)
C
10/13/2022
Violation issued (HPD, closed)
B
10/13/2022
Violation issued (HPD, closed)
C
10/13/2022
Violation issued (HPD, closed)
C
10/13/2022
Violation issued (HPD, closed)
A
10/13/2022
Violation issued (HPD, closed)
B
10/13/2022
Violation issued (HPD, closed)
B
10/13/2022
Violation issued (HPD, closed)
C
10/13/2022
Violation issued (HPD, closed)
B
10/06/2022
Violation issued (HPD, closed)
C
10/06/2022
Violation issued (HPD, closed)
C
10/06/2022
Violation issued (HPD, closed)
B
10/04/2022
Violation issued (HPD, closed)
B
10/04/2022
Violation issued (HPD, closed)
C
10/04/2022
Violation issued (HPD, closed)
B
10/04/2022
Violation issued (HPD, closed)
C
10/04/2022
Violation issued (HPD, closed)
B
10/04/2022
Violation issued (HPD, closed)
B
09/28/2022
Violation issued (HPD, closed)
B
09/28/2022
Violation issued (HPD, closed)
B
09/28/2022
Violation issued (HPD, closed)
C
09/28/2022
Violation issued (HPD, closed)
B
09/28/2022
Violation issued (HPD, closed)
C
09/16/2022
Violation issued (HPD, closed)
C
09/16/2022
Violation issued (HPD, closed)
A
09/16/2022
Violation issued (HPD, closed)
C
09/16/2022
Violation issued (HPD, closed)
C
09/16/2022
Violation issued (HPD, closed)
B
09/16/2022
Violation issued (HPD, closed)
B
09/16/2022
Violation issued (HPD, closed)
B
09/16/2022
Violation issued (HPD, closed)
B
09/16/2022
Violation issued (HPD, closed)
B
09/16/2022
Violation issued (HPD, closed)
B
09/16/2022
Violation issued (HPD, closed)
B
09/16/2022
Violation issued (HPD, closed)
C
09/03/2022
Violation issued (HPD, closed)
C
09/03/2022
Violation issued (HPD, closed)
B
08/09/2022
Violation issued (HPD, closed)
C
08/09/2022
Violation issued (HPD, closed)
C
08/09/2022
Violation issued (HPD, closed)
B
08/09/2022
Violation issued (HPD, closed)
B
08/09/2022
Violation issued (HPD, closed)
B
08/09/2022
Violation issued (HPD, closed)
B
08/09/2022
Violation issued (HPD, closed)
B
08/09/2022
Violation issued (HPD, closed)
B
Latest 60 of 71 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offTARGET PIPING NY LLC06/05/2020
DOB NOWBoiler EquipmentPermit IssuedTARGET PIPING NY LLC03/27/2020
Nothing on file for this building.
▾Special Inspection Requirements (DOB NOW) — 3
DateRequirementInspectorRole
01/09/2020Heating SystemsDavid Katzspecial
01/09/2020Maintenance informationDavid Katzenergy_progress
01/09/2020HVAC and service water heating equipment David Katzenergy_progress
▾Documents — 11 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch - Plumbing1
08/26/2026X00293868-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Boiler Equipment1
08/14/2026X00293849-I1Request digital key ↗
▸Seals & Professional Certifications5
▸DOB NOWProgress Inspector Seal & Signature2
09/23/2026X00293849-I1Open ↗
09/23/2026X00293849-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/26/2026X00293849-I1Open ↗
08/13/2026X00293868-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
09/23/2026X00293849-I1Open ↗
▸Safety & Tenant Protection2
▸DOB NOWTenant Protection Plan2
08/13/2026X00293868-I1Open ↗
08/13/2026X00293849-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/14/2026X00293849-I1Open ↗
08/13/2026X00293868-I1Open ↗