← Back
One story - permanent living quarter
2109 NORTH RAILROAD AVE
STATEN ISLAND · Oakwood-Richmondtown · BIN 5064009
💬 Discuss this project
1955Year Built
1Stories
A2Building Class
R3XZoning
1,144 sfGross Floor Area
1Units
One story - permanent living quarter · 4,080 sf lot · 0.28 FAR built · Flood zone X
Locations of Work
Electrical
Roof3p · 1 filing · 12 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
PARKER AND WEST ENGINEERING, PLLC205/07/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SUNRUN INSTALLATION SVCGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
PARKER AND WEST ENGINEERI5272205/07/2026
Building Lifecycle
All (9)Filed (2)Permit Issued (1)Signed Off (1)Special Inspection (5)
06/18/2026
Signed off — Alteration
FILING HEREWITH TAX ABATEMENT APPLICATION FOR INSTALLATION OF ROOF MOUNTED SOLAR PANELS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
S01385219-I1
05/07/2026
Filed — Alteration
FILING HEREWITH TAX ABATEMENT APPLICATION FOR INSTALLATION OF ROOF MOUNTED SOLAR PANELS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
S01385219-P1
05/07/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
Walid Abdulla
05/06/2026
Special inspection requirement — Energy Code Compliance Inspections
Walid Abdulla
05/06/2026
Special inspection requirement — Final
Walid Abdulla
05/06/2026
Special inspection requirement — Air barrier - visual inspection
Walid Abdulla
05/06/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Walid Abdulla
04/28/2026
Permit issued — Solar
S01385219-I1-SL
04/14/2026
Filed — Alteration
FILING HEREWITH TAX ABATEMENT APPLICATION FOR INSTALLATION OF ROOF MOUNTED SOLAR PANELS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
S01385219-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offSUNRUN INSTALLATION SVC04/28/2026
1 project · most recent 04/14/2026
FiledStatusContractorScope
04/14/2026CompleteSUNRUN SOLAR ELECTL CORP—
1 project · most recent 05/07/2026
FiledStatusContractorScope
05/07/2026Signed-offSUNRUN INSTALLATION SVC27 panels, 12.15 kw, 568 roof_area_sqft
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
05/07/2026Structural Stability – Alterations of existing buildingsWalid Abdullaspecial
05/06/2026Energy Code Compliance InspectionsWalid Abdullaprogress
05/06/2026FinalWalid Abdullaprogress
05/06/2026Air barrier - visual inspectionWalid Abdullaenergy_progress
05/06/2026Fire-Resistant Penetrations and JointsWalid Abdullaspecial
▾Documents — 12 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/17/2026S01385219-I1Request digital key ↗
08/17/2026S01385219-P1Request digital key ↗
▸Seals & Professional Certifications7
▸DOB NOWProgress Inspector Seal & Signature3
09/01/2026S01385219-P1Open ↗
09/01/2026S01385219-P1Open ↗
09/01/2026S01385219-P1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/17/2026S01385219-P1Open ↗
08/17/2026S01385219-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
09/01/2026S01385219-P1Open ↗
09/01/2026S01385219-P1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/17/2026S01385219-P1Open ↗
08/17/2026S01385219-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/17/2026S01385219-I1Open ↗