← Back
Primarily 2 family with 1 store or office
211-07 JAMAICA AVENUE
QUEENS · Queens Village · BIN 4224609
💬 Discuss this project
1939Year Built
2Stories
S2Building Class
R3-2Zoning
2,272 sfGross Floor Area
3Units
7 Open Violations ▸FDNY Report ↗
Primarily 2 family with 1 store or office · 1,335 sf lot · 1.7 FAR built · Flood zone X
Locations of Work
Architecture
Floor 23p · 1 filing · 14 docs
Floor 13p · 1 filing · 14 docs
Cellar3p · 1 filing · 14 docs
Site & exterior3p · 1 filing · 14 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
EDGAR NELSON INC103/22/2026
211-07 JAMAICA AVENUE COR103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
09/14/2023$860K—EDGAR NELSON INC → Private party$379/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ASKON ARCHITECTS, P.C.211/21/2023
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ASSURED BUILDERS INCGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ASKON ARCHITECT, P.C.3596211/21/2023
Building Lifecycle
All (56)Filed (2)Permit Issued (1)Signed Off (1)Violation (42)Objection (2)Special Inspection (8)
12/15/2023
Signed off — Alteration
FILING TO REMOVE NON LOAD BEARING WALLS AT CELLAR AND INSTALL HVAC UNITS. DECOMMISSION EXISTING COMMERCIAL SPACE BOILER, REPLACE WITH NEW HVAC
Q00873813-I1
12/04/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Akeeb Shekoni
12/04/2023
Special inspection requirement — Mechanical Systems
Akeeb Shekoni
12/04/2023
Special inspection requirement — Final
HANSA PERSAUD
12/04/2023
Special inspection requirement — Energy Code Compliance Inspections
Akeeb Shekoni
11/21/2023
Filed — Alteration
FILING TO REMOVE NON LOAD BEARING WALLS AT CELLAR AND INSTALL HVAC UNITS. DECOMMISSION EXISTING COMMERCIAL SPACE BOILER, REPLACE WITH NEW HVAC
Q00873813-P2
11/20/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Akeeb Shekoni
11/20/2023
Special inspection requirement — Mechanical Systems
Akeeb Shekoni
11/20/2023
Special inspection requirement — Energy Code Compliance Inspections
Akeeb Shekoni
11/20/2023
Special inspection requirement — Final
HANSA PERSAUD
08/02/2023
Permit issued — General Construction
Q00873813-I1-GC-CX
06/30/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/30/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/20/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/20/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/08/2023
Objection raised — Other
06/08/2023
Objection resolved — Addressed
06/04/2023
Filed — Alteration
FILING TO REMOVE NON LOAD BEARING WALLS AT CELLAR AND INSTALL HVAC UNITS. DECOMMISSION EXISTING COMMERCIAL SPACE BOILER, REPLACE WITH NEW HVAC
Q00873813-I1
04/25/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/10/2022
Violation issued (HPD, open)
I
02/09/2022
Violation issued (HPD, closed)
C
02/09/2022
Violation issued (HPD, open)
B
09/27/2020
Violation issued (HPD, open)
B
09/27/2020
Violation issued (HPD, open)
B
09/27/2020
Violation issued (HPD, open)
A
07/22/2020
Violation issued (HPD, open)
B
07/22/2020
Violation issued (HPD, open)
B
04/16/2020
Violation issued (ECB, closed)
Boilers
12/04/2018
Violation issued (ECB, closed)
Boilers
09/23/2016
Violation issued (FDNY_NOV, closed)
12/17/2011
Violation issued (HPD, closed)
C
11/16/2011
Violation issued (HPD, closed)
B
07/15/2008
Violation issued (ECB, closed)
Construction
07/09/2008
Violation issued (HPD, closed)
C
07/09/2008
Violation issued (HPD, closed)
B
07/09/2008
Violation issued (HPD, closed)
B
07/09/2008
Violation issued (HPD, closed)
C
06/27/2008
Violation issued (HPD, closed)
C
06/27/2008
Violation issued (HPD, closed)
A
06/27/2008
Violation issued (HPD, closed)
B
06/27/2008
Violation issued (HPD, closed)
B
06/27/2008
Violation issued (HPD, closed)
B
06/27/2008
Violation issued (HPD, closed)
B
06/27/2008
Violation issued (HPD, closed)
B
06/27/2008
Violation issued (HPD, closed)
B
06/27/2008
Violation issued (HPD, closed)
C
06/27/2008
Violation issued (HPD, closed)
B
06/27/2008
Violation issued (HPD, closed)
A
06/27/2008
Violation issued (HPD, closed)
B
06/27/2008
Violation issued (HPD, closed)
B
06/27/2008
Violation issued (HPD, closed)
B
06/27/2008
Violation issued (HPD, closed)
B
06/27/2008
Violation issued (HPD, closed)
B
09/25/2005
Violation issued (HPD, closed)
C
09/25/2005
Violation issued (HPD, closed)
C
02/23/2002
Violation issued (HPD, closed)
A
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offASSURED BUILDERS INC08/02/2023
1 project · most recent 11/21/2023
Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
11/21/2023Signed-offASSURED BUILDERS INCAir Conditioning Systems
Cooling
Rheem UAKA-037JAZ; RP1436AJINA 36,000 BTU · Split System ×4
Goodman GSZ14036IKE 140,000 BTU · Heat Pump Outdoor ×2
▾Special Inspection Requirements (DOB NOW) — 8
DateRequirementInspectorRole
12/04/2023Fire-Resistant Penetrations and JointsAkeeb Shekonispecial
12/04/2023Mechanical SystemsAkeeb Shekonispecial
12/04/2023FinalHANSA PERSAUDprogress
12/04/2023Energy Code Compliance InspectionsAkeeb Shekoniprogress
11/20/2023Fire-Resistant Penetrations and JointsAkeeb Shekonispecial
11/20/2023Mechanical SystemsAkeeb Shekonispecial
11/20/2023Energy Code Compliance InspectionsAkeeb Shekoniprogress
11/20/2023FinalHANSA PERSAUDprogress
▾Documents — 14 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/23/2026Q00873813-P2Request digital key ↗
08/14/2026Q00873813-I1Request digital key ↗
▸Seals & Professional Certifications10
▸DOB NOWProgress Inspector Seal & Signature4
09/01/2026Q00873813-P2Open ↗
09/01/2026Q00873813-P2Open ↗
08/25/2026Q00873813-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
09/01/2026Q00873813-P2Open ↗
09/01/2026Q00873813-P2Open ↗
08/25/2026Q00873813-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/13/2026Q00873813-P2Open ↗
08/13/2026Q00873813-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/13/2026Q00873813-P2Open ↗
08/13/2026Q00873813-I1Open ↗