← Back
Walk-up apt, over six families with stores
213 1 AVENUE
MANHATTAN · BIN 1006491
💬 Discuss this project
1900Year Built
5Stories
C7Building Class
R7AZoning
10,973 sfGross Floor Area
10Units
Rent Stabilized1 Open Violation ▸
Walk-up apt, over six families with stores · Owner of record: 211-217 FIRST AVENUE LLC · 2,723 sf lot · 4.03 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbing
Roof3p · 2 filings · 19 docs
Floor 51p · 1 filing · 12 docs
Floor 4
Floor 3
Floor 2
Floor 13p · 2 filings · 20 docs
1 job · most recent 07/30/2025
Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
07/30/2025Permit IssuedHIGH QUALITY CONSTRUCTIONAir Conditioning Systems, Ventilation Systems
Cooling
Daikin 4MXLH36WVJU9, 4MXLH36WVJU9 36,000 BTU · Heat Pump Outdoor ×2
1 job · most recent 12/19/2025
Gas Water/Sanitary
FiledStatusContractorScope
12/19/2025Signed-offAMERICAN STANDARD P&H CORGas, Water/Sanitary
9 jobs · most recent 05/17/2026
General Wiring
FiledStatusContractorScope
05/17/2026Pending PaymentAMOR ELECTRIC CORPGeneral Wiring
01/27/2021CompleteUNITED ELEC'L CONT'G CORP11 meters, 10 new_meters
11/17/2020CompletePOWER SURGE ELECTRIC, INCGeneral Wiring
09/29/2020CompletePOWER SURGE ELECTRIC, INCGeneral Wiring
03/12/2020CompletePOWER SURGE ELECTRIC, INCGeneral Wiring
02/07/2020CompletePOWER SURGE ELECTRIC, INCGeneral Wiring
12/06/2019CompletePOWER SURGE ELECTRIC, INCGeneral Wiring
12/06/2019CompletePOWER SURGE ELECTRIC, INCGeneral Wiring
01/09/2019Permit IssuedMAXIMUM ELECTRIC CORP.General Wiring
Building Lifecycle
All (102)Filed (9)Permit Issued (6)Signed Off (3)Violation (60)Inspection (3)Special Inspection (21)
01/21/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
01/21/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
01/21/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
12/22/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
NARESH MAHANGU
12/22/2025
Special inspection requirement — Energy Code Compliance Inspections
NARESH MAHANGU
12/22/2025
Special inspection requirement — Tenant Protection Plan Compliance
12/19/2025
Filed — Alteration
FILE PLUMBING WORK IN CONJUNCTION WITH JOB #M01262698. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M01264172-P2
12/19/2025
Special inspection requirement — Tenant Protection Plan Compliance
12/18/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
NARESH MAHANGU
12/18/2025
Special inspection requirement — Energy Code Compliance Inspections
NARESH MAHANGU
10/08/2025
Violation issued (ECB, closed)
Unknown
10/08/2025
Violation issued (ECB, closed)
Site Safety
09/08/2025
Filed — Alteration
FILE PLUMBING WORK IN CONJUNCTION WITH JOB #M01262698. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M01264172-P1
09/03/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
NARESH MAHANGU
09/03/2025
Special inspection requirement — Energy Code Compliance Inspections
NARESH MAHANGU
09/03/2025
Special inspection requirement — Tenant Protection Plan Compliance
09/01/2025
Violation issued (HPD, closed)
B
08/05/2025
Permit issued — Mechanical Systems
M01262698-I1-MS
08/05/2025
Permit issued — General Construction
M01262698-I1-GC
08/04/2025
Permit issued — Plumbing
M01264172-I1-PL
07/30/2025
Filed — Alteration
FILE PLUMBING WORK IN CONJUNCTION WITH JOB #M01262698. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M01264172-I1
07/30/2025
Filed — Alteration
RENOVATION OF AN EXISTING COMMERCIAL SPACE ON 1ST FLOOR WITH FLOOR TILES, PAINTING, CEILING WORK AS PER PLAN. INSTALL A TYPE-1 RANGEHOOD AT THE ACCESSORY KITCHEN. INSTALL EXHAUST DUCTS AND ROOFTOP BLOWERS AS PER PLAN. NO CHANGE IN USE, EGRESS OR OCCUPANCY
M01262698-I1
07/30/2025
Special inspection requirement — HVAC-R and service water heating system controls
NARESH MAHANGU
07/30/2025
Special inspection requirement — HVAC-R and service water heating equipment
NARESH MAHANGU
07/30/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
NARESH MAHANGU
07/30/2025
Special inspection requirement — Tenant Protection Plan Compliance
NARESH MAHANGU
07/30/2025
Special inspection requirement — Energy Code Compliance Inspections
NARESH MAHANGU
07/30/2025
Special inspection requirement — Fire-Resistance Rated Construction
NARESH MAHANGU
07/30/2025
Special inspection requirement — Insulation placement and R values
NARESH MAHANGU
07/30/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
NARESH MAHANGU
07/30/2025
Special inspection requirement — Shutoff dampers
NARESH MAHANGU
07/30/2025
Special inspection requirement — Interior lighting power
NARESH MAHANGU
07/28/2025
Special inspection requirement — Mechanical Systems
NARESH MAHANGU
07/28/2025
Special inspection requirement — Final
Chun Feng
06/12/2025
Violation issued (HPD, closed)
C
06/12/2025
Violation issued (HPD, closed)
C
06/12/2025
Violation issued (HPD, closed)
C
06/04/2025
Violation issued (HPD, closed)
A
12/05/2023
Violation issued (HPD, closed)
B
11/17/2023
Signed off — Alteration
PLUMBING FILED FOR APT 1. PLUMBING WORK AS PER PLANS. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
M00390419-I1
11/17/2023
Signed off — Alteration
PLUMBING FILING FOR APARTMENTS 3 & 7. PLUMBING WORK AS PER PLANS.GENERAL CONSTRUCTION FILED UNDER JOB #140871821. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
M00239692-I1
11/17/2023
Signed off — Alteration
M00322898-I1
09/24/2023
Violation issued (HPD, closed)
B
08/25/2023
Violation issued (HPD, closed)
C
08/25/2023
Violation issued (HPD, closed)
B
08/25/2023
Violation issued (HPD, closed)
C
08/25/2023
Violation issued (HPD, closed)
B
08/25/2023
Violation issued (HPD, closed)
A
08/25/2023
Violation issued (HPD, closed)
B
08/25/2023
Violation issued (HPD, closed)
B
08/25/2023
Violation issued (HPD, closed)
C
08/25/2023
Violation issued (HPD, closed)
B
08/25/2023
Violation issued (HPD, closed)
C
08/25/2023
Violation issued (HPD, closed)
B
08/25/2023
Violation issued (HPD, closed)
C
08/25/2023
Violation issued (HPD, closed)
B
08/25/2023
Violation issued (HPD, closed)
C
08/25/2023
Violation issued (HPD, closed)
A
03/15/2023
Violation issued (HPD, closed)
A
03/20/2022
Violation issued (HPD, closed)
C
Latest 60 of 102 events.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
SANI GROUP1607/08/2026
211-217 FIRST AVENUE1103/22/2026
50 SYMPHONY ROAD803/22/2026
CHITO303/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CHUN FENG, ARCHITECT412/19/2025
ATELIER NY ARCHITECTURE509/03/2020
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
HIGH QUALITY 338803/21/2026
ATELIER NEW YORK ARCHITECTURE503/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
HIGH QUALITY CONSTRUCTIONGeneral Contractor304/09/2026
CROSSFIELD PLBG.&HTGPlumbing207/08/2026
POWER SURGE ELECTRIC, INCElectrical203/22/2026
CRUGNALE, MICHAELElectrical103/21/2026
DIFUSCO, ALFONSOElectrical103/21/2026
AAA TOTAL PLUMBING, INCPlumbing107/08/2026
AMERICAN STANDARD P&H CORORP.Plumbing107/04/2026
DUNN, JEREMYElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NKM ENGINEERING PLLC6244412/19/2025
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedHIGH QUALITY CONSTRUCTION08/05/2025
DOB NOWGeneral ConstructionPermit IssuedHIGH QUALITY CONSTRUCTION08/05/2025
DOB NOWPlumbingSigned-offAMERICAN STANDARD P&H CORORP.08/04/2025
DOB NOWPlumbingSigned-offCROSSFIELD PLBG.&HTG09/14/2020
DOB NOWPlumbingSigned-offCROSSFIELD PLBG.&HTG07/18/2020
DOB NOWPlumbingSigned-offAAA TOTAL PLUMBING, INC11/22/2019
BISOTISSUEDHONOR CONSTRUCTION INC01/28/2021
BISOTISSUEDHONOR CONSTRUCTION INC01/28/2021
BISOTISSUEDHONOR CONSTRUCTION INC09/16/2020
BISOTISSUEDHONOR CONSTRUCTION INC08/28/2020
BISOTISSUEDHONOR CONSTRUCTION INC02/27/2020
BISOTISSUEDHONOR CONSTRUCTION INC02/12/2020
BISOTISSUEDHONOR CONSTRUCTION INC02/06/2020
BISPLISSUEDSPEEDWAY PLUMBING CORP01/13/2020
BISPLISSUEDSPEEDWAY PLUMBING CORP01/15/2019
BISEQISSUEDROBIN INDUSTRIES LTD01/13/2004
BISOTISSUEDROBIN INDUSTRIES LTD01/13/2004
BISFPISSUEDACTIVE FIRE EXTINGUSIHER INC02/03/1997
BISPLISSUEDGW MECHANICAL CORP12/23/1996
BISEQISSUEDOMNI PLATE GLASS STORE FRONT MIR12/23/1996
BISMHISSUEDINTER MECHANICAL CORP.12/23/1996
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
01/21/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
01/21/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
01/21/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 21
DateRequirementInspectorRole
12/22/2025Fire-Resistant Penetrations and JointsNARESH MAHANGUspecial
12/22/2025Energy Code Compliance InspectionsNARESH MAHANGUprogress
12/22/2025Tenant Protection Plan Compliance—special
12/19/2025Tenant Protection Plan Compliance—special
12/18/2025Fire-Resistant Penetrations and JointsNARESH MAHANGUspecial
12/18/2025Energy Code Compliance InspectionsNARESH MAHANGUprogress
09/03/2025Fire-Resistant Penetrations and JointsNARESH MAHANGUspecial
09/03/2025Energy Code Compliance InspectionsNARESH MAHANGUprogress
09/03/2025Tenant Protection Plan Compliance—special
07/30/2025HVAC-R and service water heating system controlsNARESH MAHANGUenergy_progress
07/30/2025HVAC-R and service water heating equipmentNARESH MAHANGUenergy_progress
07/30/2025Fire-Resistant Penetrations and JointsNARESH MAHANGUspecial
07/30/2025Tenant Protection Plan ComplianceNARESH MAHANGUspecial
07/30/2025Energy Code Compliance InspectionsNARESH MAHANGUprogress
07/30/2025Fire-Resistance Rated ConstructionNARESH MAHANGUprogress
07/30/2025Insulation placement and R valuesNARESH MAHANGUenergy_progress
07/30/2025HVAC-R and service water piping design and insulationNARESH MAHANGUenergy_progress
07/30/2025Shutoff dampersNARESH MAHANGUenergy_progress
07/30/2025Interior lighting powerNARESH MAHANGUenergy_progress
07/28/2025Mechanical SystemsNARESH MAHANGUspecial
07/28/2025FinalChun Fengprogress
▾Documents — 177 on file (BIS + DOB NOW)
▸Plans & Drawings9
▸DOB NOWPlans/Sketch - Plumbing5
09/05/2026M00239692-I1Request digital key ↗
09/04/2026M00322898-I1Request digital key ↗
09/04/2026M00390419-I1Request digital key ↗
Showing 3 of 5 on file for this type
▸DOB NOWPlans/Sketch4
08/22/2026M01262698-I1Request digital key ↗
08/22/2026M01264172-P2Request digital key ↗
08/22/2026M01264172-P1Request digital key ↗
Showing 3 of 4 on file for this type
▸Applications & Permits30
▸BISPLAN / WORK APPROVAL APPLICATION19
03/15/2021101435582Open ↗
01/26/2021140946975Open ↗
01/14/2021140946975Open ↗
Showing 3 of 19 on file for this type
▸BISWORK PERMIT APPLICATION10
01/28/2021140946975Open ↗
01/28/2021140881491Open ↗
01/13/2021140946975Open ↗
Showing 3 of 10 on file for this type
▸BISPLAN - WORK & PERMITS - SUPPPORTING DOCUMENTATION1
01/14/2021140946975Open ↗
▸Seals & Professional Certifications37
▸DOB NOWDPL-1: Design Professional Seal & Signature9
09/05/2026M00239692-P1Open ↗
09/05/2026M00239692-P2Open ↗
09/05/2026M00239692-I1Open ↗
Showing 3 of 9 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT6
09/02/2020140946975Open ↗
08/26/2020140944405Open ↗
02/26/2020140889000Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWProgress Inspector Seal & Signature6
09/23/2026M01262698-I1Open ↗
09/23/2026M01262698-I1Open ↗
09/23/2026M01262698-I1Open ↗
Showing 3 of 6 on file for this type
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION5
09/02/2020140946975Open ↗
08/26/2020140944405Open ↗
02/26/2020140889000Open ↗
Showing 3 of 5 on file for this type
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY5
09/02/2020140946975Open ↗
08/26/2020140944405Open ↗
02/26/2020140889000Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
09/23/2026M01262698-I1Open ↗
08/26/2026M01264172-P1Open ↗
08/23/2026M01264172-I1Open ↗
Showing 3 of 4 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
01/15/2019123154905Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
01/15/2019123154905Open ↗
▸Trade Schedules & Equipment3
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE3
01/06/2020123154905Open ↗
12/23/2019123154905Open ↗
01/15/2019123154905Open ↗
▸Safety & Tenant Protection11
▸BISTENANT PROTECTION PLAN AND NOTES6
01/14/2021140946975Open ↗
08/26/2020140944405Open ↗
02/26/2020140889000Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWTenant Protection Plan5
09/04/2026M00390419-I1Open ↗
08/13/2026M00239692-P1Open ↗
08/13/2026M00322898-I1Open ↗
Showing 3 of 5 on file for this type
▸Environmental & Asbestos15
▸DOB NOWDEP ACP-5: Asbestos Assessment Report9
09/05/2026M00239692-P1Open ↗
09/05/2026M00239692-P2Open ↗
09/05/2026M00239692-I1Open ↗
Showing 3 of 9 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)6
09/02/2020140946975Open ↗
08/26/2020140944405Open ↗
02/26/2020140889000Open ↗
Showing 3 of 6 on file for this type
▸Energy Compliance24
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY12
05/06/2021140946975Open ↗
05/06/2021140946975Open ↗
02/10/2021140881491Open ↗
Showing 3 of 12 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS6
05/06/2021140946975Open ↗
04/19/2021140946975Open ↗
02/10/2021140881491Open ↗
Showing 3 of 6 on file for this type
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS5
09/02/2020140946975Open ↗
08/26/2020140944405Open ↗
02/26/2020140889000Open ↗
Showing 3 of 5 on file for this type
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
01/15/2019123154905Open ↗
▸Inspections & Test Reports12
▸BISTECHNICAL REPORT: RESPONSIBILITY12
05/06/2021140946975Open ↗
04/19/2021140946975Open ↗
02/10/2021140881491Open ↗
Showing 3 of 12 on file for this type
▸Approvals, Objections & Sign-offs5
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST5
05/06/2021140946975Open ↗
02/10/2021140881491Open ↗
01/06/2021140944405Open ↗
Showing 3 of 5 on file for this type
▸Cost, Insurance & Ownership17
▸BISCOST AFFIDAVIT12
05/06/2021140946975Open ↗
04/19/2021140946975Open ↗
02/10/2021140881491Open ↗
Showing 3 of 12 on file for this type
▸BISHIC LICENSE OR AFFIDAVIT5
09/02/2020140946975Open ↗
08/26/2020140944405Open ↗
02/26/2020140889000Open ↗
Showing 3 of 5 on file for this type
▸Filing & Intake Forms14
▸BISEFILING JOB APPLICATION COVER SHEET5
09/02/2020140946975Open ↗
08/26/2020140944405Open ↗
02/26/2020140889000Open ↗
Showing 3 of 5 on file for this type
▸BISADDITIONAL INFORMATION5
01/14/2021140946975Open ↗
03/11/2020140871821Open ↗
01/15/2020123154905Open ↗
Showing 3 of 5 on file for this type
▸BISBOROUGH INTAKE FORM3
12/23/2019123154905Open ↗
06/27/2019123154905Open ↗
06/20/2019123154905Open ↗
▸BISEFILING COVER SHEET1
01/15/2019123154905Open ↗