← Back
Two stories - detached, small or mid-size
211-28 45 DRIVE
QUEENS · BIN 4156925
💬 Discuss this project
1920Year Built
2.5Stories
A1Building Class
R3AZoning
1,335 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
Two stories - detached, small or mid-size · 2,500 sf lot · 0.53 FAR built · Flood zone X
Locations of Work
Architecture
Cellar1p · 1 filing · 20 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
MADRIAGA ENGINEERING P.C.509/09/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
BERNARDO GAMBA403/21/2026
Building Lifecycle
All (33)Filed (5)Violation (2)Objection (4)Special Inspection (22)
10/14/2025
Objection raised — Zoning
10/14/2025
Objection raised — Plumbing
09/09/2025
Filed — Alteration CO
MH APPLICATION FILED IN CONJUNCTION WITH DOB NOW APPLICATION Q01105457 -I1
Q01105457-S6
09/03/2025
Special inspection requirement — HVAC-R and service water heating equipment
07/28/2025
Special inspection requirement — Final
07/28/2025
Special inspection requirement — Mechanical Systems
07/28/2025
Special inspection requirement — HVAC-R and service water heating equipment
07/28/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
07/28/2025
Special inspection requirement — HVAC-R and service water heating system controls
06/20/2025
Objection resolved — Addressed
05/22/2025
Objection raised — Other
05/13/2025
Special inspection requirement — Maintenance information
05/13/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
12/14/2024
Filed — Alteration CO
MH APPLICATION FILED IN CONJUNCTION WITH DOB NOW APPLICATION Q01105457 -I1
Q01105457-S4
11/11/2024
Filed — Alteration CO
MH APPLICATION FILED IN CONJUNCTION WITH DOB NOW APPLICATION Q01105457 -I1
Q01105457-S2
11/11/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
11/11/2024
Special inspection requirement — Energy Code Compliance Inspections
11/11/2024
Special inspection requirement — HVAC-R and service water heating equipment
11/11/2024
Special inspection requirement — HVAC-R and service water heating system controls
11/11/2024
Special inspection requirement — Energy Code Compliance Inspections
11/10/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
11/10/2024
Special inspection requirement — Permanent certificate
11/10/2024
Special inspection requirement — Insulation placement and R values
11/10/2024
Special inspection requirement — Air barrier - visual inspection
11/10/2024
Special inspection requirement — Fenestration areas
09/11/2024
Filed — Alteration CO
MH APPLICATION FILED IN CONJUNCTION WITH DOB NOW APPLICATION Q01105457 -I1
Q01105457-I1
09/10/2024
Filed — Alteration
Q01105556-I1
09/03/2024
Special inspection requirement — Footing and Foundation
09/03/2024
Special inspection requirement — Final
09/03/2024
Special inspection requirement — Wood – Prefabricated I-Joists
09/03/2024
Special inspection requirement — Construction Utilizing CLT or SCL, Type IV
05/06/2005
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/26/2004
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
BISPLISSUEDSUNSET PLUMBING & FIRE PROTECTIO01/31/2005
1 project · most recent 09/09/2025
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
09/09/2025——Heating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Goodman GSXC16-0361F 36,000 BTU · Furnace ×1
Ventilation
Panasonic FV-0511 VKSL2 80 CFM · Exhaust Fan ×5
FV-1115VQL1 150 CFM · Kitchen Exhaust ×2
▾Special Inspection Requirements (DOB NOW) — 22
DateRequirementInspectorRole
09/03/2025HVAC-R and service water heating equipment—energy_progress
07/28/2025Final—progress
07/28/2025Mechanical Systems—special
07/28/2025HVAC-R and service water heating equipment—energy_progress
07/28/2025HVAC-R and service water piping design and insulation—energy_progress
07/28/2025HVAC-R and service water heating system controls—energy_progress
05/13/2025Maintenance information—energy_progress
05/13/2025HVAC-R and service water piping design and insulation—energy_progress
11/11/2024Fire-Resistant Penetrations and Joints—special
11/11/2024Energy Code Compliance Inspections—progress
11/11/2024HVAC-R and service water heating equipment—energy_progress
11/11/2024HVAC-R and service water heating system controls—energy_progress
11/11/2024Energy Code Compliance Inspections—progress
11/10/2024Fenestration and door U-factor and product ratings—energy_progress
11/10/2024Permanent certificate—energy_progress
11/10/2024Insulation placement and R values—energy_progress
11/10/2024Air barrier - visual inspection—energy_progress
11/10/2024Fenestration areas—energy_progress
09/03/2024Footing and Foundation—progress
09/03/2024Final—progress
09/03/2024Wood – Prefabricated I-Joists—special
09/03/2024Construction Utilizing CLT or SCL, Type IV—special
▾Documents — 26 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch6
08/21/2026Q01105556-I1Request digital key ↗
08/19/2026Q01105457-I1Request digital key ↗
08/19/2026Q01105457-S5Request digital key ↗
Showing 3 of 6 on file for this type
▸Zoning, Tax Lot & Property Records2
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026Q01105457-I1Open ↗
▸DOB NOWZD1: DOB Zoning Diagram1
08/13/2026Q01105457-I1Open ↗
▸Seals & Professional Certifications6
▸DOB NOWDPL-1: Design Professional Seal & Signature6
08/21/2026Q01105556-I1Open ↗
08/13/2026Q01105457-S6Open ↗
08/13/2026Q01105457-S5Open ↗
Showing 3 of 6 on file for this type
▸Safety & Tenant Protection1
▸DOB NOWStreet Tree Checklist1
08/13/2026Q01105457-I1Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/13/2026Q01105457-S6Open ↗
08/13/2026Q01105457-S2Open ↗
08/13/2026Q01105457-I1Open ↗
Showing 3 of 4 on file for this type
▸Inspections & Test Reports2
▸DOB NOWGeotechnical Report (BC 1803.6)2
08/13/2026Q01105457-I1Open ↗
08/13/2026Q01105457-S4Open ↗
▸Other Documents5
▸DOB NOWPlot Diagram2
08/13/2026Q01105457-I1Open ↗
08/13/2026Q01105457-S4Open ↗
▸DOB NOWSite Survey: Initial1
08/13/2026Q01105457-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026Q01105457-I1Open ↗
▸DOB NOWProperty Ownership Certification1
08/13/2026Q01105457-I1Open ↗