← Back
Over six families without stores
2110 HONEYWELL AVENUE
BRONX · West Farms · BIN 2013176
💬 Discuss this project
1911Year Built
5Stories
C1Building Class
R7-1Zoning
12,659 sfGross Floor Area
10Units
Rent Stabilized44 Open Violations 41 unresolved · 3 paperwork only ▸
Over six families without stores · Owner of record: HONEYWELL RESIDENTS LLC · 2,993 sf lot · 4.23 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbingFire ProtectionGeneral
Permit Issued — active, not yet Signed-off
RoofUnder Construction25p · 1 filing · 20 docs
Floor 5Under Construction23p · 1 filing · 20 docs
Floor 4Under Construction23p · 1 filing · 20 docs
Floor 3Under Construction26p · 1 filing · 20 docs
Floor 2Under Construction25p · 1 filing · 20 docs
Floor 1Under Construction24p · 1 filing · 20 docs
CellarUnder Construction28p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
RESIDENTS GROUP1209/13/2026
HONEYWELL RESIDENTS LLC103/22/2026
2110 HONEYWELL LLC1103/22/2026
ISLAND REAL ESTATE DVLP L103/22/2026
ALLIAH MANAGEMENT103/22/2026
LIGHTSTONE MANAGEMENT103/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
12/28/2023$1.9M—2110 HONEYWELL LLC → HONEYWELL RESIDENTS LLC$146/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
LESTER KATZ, NCARB705/29/2026
VASILIOS ARTEMIOU PE202/11/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
EXPRESS FILING INC1403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
HILLEL DIAMANTElectrical603/21/2026
MJH CONSTRUCTION CORPGeneral Contractor208/21/2026
ANGELO DOMINGUEZElectrical103/21/2026
QUALITY PIPING, INCFire Protection107/08/2026
NESS MECHANICAL P & H INCPlumbing107/08/2026
YOSEF BLAUElectrical103/21/2026
CURRENT MECHS ELEC CONTSElectrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
HRF SERVICES CORP5616505/29/2026
Building Lifecycle
All (167)Filed (9)Permit Issued (4)Violation (60)Objection (64)Special Inspection (30)
08/20/2026
Permit issued — Mechanical Systems
X01011956-S1-MS
06/17/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
SHAHRIAR QUAYYUM
06/17/2026
Special inspection requirement — Energy Code Compliance Inspections
SHAHRIAR QUAYYUM
06/17/2026
Special inspection requirement — HVAC-R and service water heating system controls
SHAHRIAR QUAYYUM
06/17/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
SHAHRIAR QUAYYUM
06/17/2026
Special inspection requirement — HVAC-R and service water heating equipment
SHAHRIAR QUAYYUM
06/17/2026
Special inspection requirement — Maintenance information
SHAHRIAR QUAYYUM
06/02/2026
Permit issued — General Construction
X01011956-I1-GC
05/29/2026
Filed — Alteration CO
PLUMBING SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION # X01011956-I1.
X01011956-A4
05/28/2026
Permit issued — Sprinklers
X01011956-S4-EW-SP
05/28/2026
Permit issued — Plumbing
X01011956-S2-PL
05/26/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
SHAHRIAR QUAYYUM
05/26/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
SHAHRIAR QUAYYUM
05/26/2026
Special inspection requirement — Energy Code Compliance Inspections
SHAHRIAR QUAYYUM
05/26/2026
Special inspection requirement — HVAC-R and service water heating system controls
SHAHRIAR QUAYYUM
05/26/2026
Special inspection requirement — Maintenance information
SHAHRIAR QUAYYUM
05/26/2026
Special inspection requirement — HVAC-R and service water heating equipment
SHAHRIAR QUAYYUM
05/18/2026
Special inspection requirement — Energy Code Compliance Inspections
SHAHRIAR QUAYYUM
05/18/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
SHAHRIAR QUAYYUM
05/18/2026
Special inspection requirement — Metering
SHAHRIAR QUAYYUM
05/18/2026
Special inspection requirement — Air barrier - visual inspection
SHAHRIAR QUAYYUM
05/18/2026
Special inspection requirement — Lighting controls
SHAHRIAR QUAYYUM
05/18/2026
Special inspection requirement — Fenestration air leakage
SHAHRIAR QUAYYUM
05/18/2026
Special inspection requirement — Exterior lighting power
SHAHRIAR QUAYYUM
05/18/2026
Special inspection requirement — Lighting in dwelling units
SHAHRIAR QUAYYUM
05/18/2026
Special inspection requirement — Fenestration areas
SHAHRIAR QUAYYUM
05/18/2026
Special inspection requirement — Interior lighting power
SHAHRIAR QUAYYUM
05/18/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
SHAHRIAR QUAYYUM
05/18/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
SHAHRIAR QUAYYUM
05/18/2026
Special inspection requirement — Fire-Resistance Rated Construction
SHAHRIAR QUAYYUM
05/13/2026
Objection raised — Cost
05/13/2026
Objection resolved — Addressed
05/13/2026
Objection resolved — Addressed
05/13/2026
Objection resolved — Addressed
05/06/2026
Objection resolved — Resolved
04/30/2026
Violation issued (HPD, open)
A
04/29/2026
Objection raised — Other
04/22/2026
Objection resolved — Addressed
04/20/2026
Objection resolved — Addressed
04/20/2026
Objection resolved — Addressed
04/13/2026
Objection resolved — Addressed
04/08/2026
Objection raised — Other
03/25/2026
Filed — Alteration CO
PLUMBING SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION # X01011956-I1.
X01011956-A2
03/24/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
03/24/2026
Special inspection requirement — HVAC-R and service water heating equipment
03/24/2026
Special inspection requirement — HVAC-R and service water heating system controls
03/24/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
03/24/2026
Special inspection requirement — Energy Code Compliance Inspections
03/16/2026
Objection resolved — Addressed
03/15/2026
Objection resolved — Addressed
02/26/2026
Objection raised — Other
02/26/2026
Objection raised — Other
02/26/2026
Objection raised — Energy
02/26/2026
Objection raised — Scope
02/24/2026
Objection resolved — Addressed
02/23/2026
Objection raised — Other
02/19/2026
Objection raised — Other
02/19/2026
Objection raised — Other
02/19/2026
Objection raised — Scope
02/11/2026
Filed — Alteration CO
PLUMBING SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION # X01011956-I1.
X01011956-A1
Latest 60 of 167 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedMJH CONSTRUCTION CORP08/20/2026
DOB NOWGeneral ConstructionPermit IssuedMJH CONSTRUCTION CORP06/02/2026
DOB NOWSprinklersPermit IssuedQUALITY PIPING, INC05/28/2026
DOB NOWPlumbingPermit IssuedNESS MECHANICAL P & H INC05/28/2026
BISPLISSUEDHAY MECHANICAL SOLUTIONS06/05/2017
BISOTISSUEDAAA HOME IMPROVEMENTS USA05/08/2017
BISBLISSUEDBAYSIDE FUEL12/13/2004
1 project · most recent 05/29/2026
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
05/29/2026Permit IssuedMJH CONSTRUCTION CORPHeating and Air Conditioning Systems
Heat / Cool
Daikin RX12AXVJU 18,000 BTU · Condensing Unit ×12
3MXS24WMVJU9 24,000 BTU · Condensing Unit ×10
2MXM18AVJU9 18,000 BTU · Condensing Unit ×1
2MXS18NMVJU 18,900 BTU · Condensing Unit ×20
1 project · most recent 05/29/2026
Sprinkler System
FiledStatusContractorScope
05/29/2026Permit IssuedQUALITY PIPING, INCSprinkler System
1 project · most recent 05/29/2026
Gas Water/Sanitary
FiledStatusContractorScope
05/29/2026Permit IssuedQUALITY PIPING, INCGas, Water/Sanitary
3 projects · most recent 12/16/2025
General Wiring
FiledStatusContractorScope
12/16/2025Permit IssuedS&R ELECTRICAL & MECHANICGeneral Wiring
05/19/2021CompleteCURRENT MECHS ELEC CONTSGeneral Wiring
12/19/2017Permit IssuedALLTECH ELECL CONTNG CORPGeneral Wiring
1 project · most recent 05/29/2026
Fence
FiledStatusContractorScope
05/29/2026Permit IssuedMJH CONSTRUCTION CORPFence
▾Special Inspection Requirements (DOB NOW) — 34
DateRequirementInspectorRole
06/17/2026Fire-Resistant Penetrations and JointsSHAHRIAR QUAYYUMspecial
06/17/2026Energy Code Compliance InspectionsSHAHRIAR QUAYYUMprogress
06/17/2026HVAC-R and service water heating system controlsSHAHRIAR QUAYYUMenergy_progress
06/17/2026HVAC-R and service water piping design and insulationSHAHRIAR QUAYYUMenergy_progress
06/17/2026HVAC-R and service water heating equipmentSHAHRIAR QUAYYUMenergy_progress
06/17/2026Maintenance informationSHAHRIAR QUAYYUMenergy_progress
05/26/2026HVAC-R and service water piping design and insulationSHAHRIAR QUAYYUMenergy_progress
05/26/2026Fire-Resistant Penetrations and JointsSHAHRIAR QUAYYUMspecial
05/26/2026Energy Code Compliance InspectionsSHAHRIAR QUAYYUMprogress
05/26/2026HVAC-R and service water heating system controlsSHAHRIAR QUAYYUMenergy_progress
05/26/2026Maintenance informationSHAHRIAR QUAYYUMenergy_progress
05/26/2026HVAC-R and service water heating equipmentSHAHRIAR QUAYYUMenergy_progress
05/18/2026Energy Code Compliance InspectionsSHAHRIAR QUAYYUMprogress
05/18/2026Fenestration and door U-factor and product ratingsSHAHRIAR QUAYYUMenergy_progress
05/18/2026MeteringSHAHRIAR QUAYYUMenergy_progress
05/18/2026Air barrier - visual inspectionSHAHRIAR QUAYYUMenergy_progress
05/18/2026Lighting controlsSHAHRIAR QUAYYUMenergy_progress
05/18/2026Fenestration air leakageSHAHRIAR QUAYYUMenergy_progress
05/18/2026Exterior lighting powerSHAHRIAR QUAYYUMenergy_progress
05/18/2026Lighting in dwelling unitsSHAHRIAR QUAYYUMenergy_progress
05/18/2026Fenestration areasSHAHRIAR QUAYYUMenergy_progress
05/18/2026Interior lighting powerSHAHRIAR QUAYYUMenergy_progress
05/18/2026Structural Stability – Alterations of existing buildingsSHAHRIAR QUAYYUMspecial
05/18/2026Fire-Resistant Penetrations and JointsSHAHRIAR QUAYYUMspecial
05/18/2026Fire-Resistance Rated ConstructionSHAHRIAR QUAYYUMprogress
Latest 25 of 34.
▾Documents — 56 on file (BIS + DOB NOW)
▸Plans & Drawings11
▸DOB NOWPlans/Sketch11
08/16/2026X01011956-A4Request digital key ↗
08/16/2026X01011956-S5Request digital key ↗
08/15/2026X01011956-S2Request digital key ↗
Showing 3 of 11 on file for this type
▸Applications & Permits3
▸BISWORK PERMIT APPLICATION2
06/05/2017240182440Open ↗
05/05/2017240182440Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION1
05/05/2017240182440Open ↗
▸Seals & Professional Certifications20
▸DOB NOWDPL-1: Design Professional Seal & Signature8
08/16/2026X01011956-A2Open ↗
08/16/2026X01011956-A1Open ↗
08/16/2026X01011956-P5Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWProgress Inspector Seal & Signature6
09/01/2026X01011956-S2Open ↗
09/01/2026X01011956-S2Open ↗
08/27/2026X01011956-A4Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature3
09/01/2026X01011956-S2Open ↗
08/27/2026X01011956-A4Open ↗
08/23/2026X01011956-I1Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
05/05/2017240182440Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
05/05/2017240182440Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
05/05/2017240182440Open ↗
▸Trade Schedules & Equipment1
▸BISSCHEDULE B - PLUMBING1
05/05/2017240182440Open ↗
▸Safety & Tenant Protection3
▸DOB NOWStreet Tree Checklist2
08/15/2026X01011956-P2Open ↗
08/14/2026X01011956-I1Open ↗
▸BISTENANT PROTECTION PLAN AND NOTES1
05/05/2017240182440Open ↗
▸Environmental & Asbestos11
▸DOB NOWDEP ACP-5: Asbestos Assessment Report10
08/16/2026X01011956-A4Open ↗
08/15/2026X01011956-S2Open ↗
08/15/2026X01011956-S2Open ↗
Showing 3 of 10 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
05/05/2017240182440Open ↗
▸Energy Compliance2
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
05/05/2017240182440Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
05/05/2017240182440Open ↗
▸Inspections & Test Reports1
▸BISTECHNICAL REPORT: RESPONSIBILITY1
05/05/2017240182440Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
05/05/2017240182440Open ↗
▸Filing & Intake Forms1
▸BISEFILING JOB APPLICATION COVER SHEET1
05/05/2017240182440Open ↗
▸Other Documents2
▸DOB NOWProperty Ownership Certification2
08/15/2026X01011956-P2Open ↗
08/14/2026X01011956-I1Open ↗