← Back
Two family frame
2111 HONE AVENUE
BRONX · BIN 2049550
💬 Discuss this project
1908Year Built
2Stories
B2Building Class
R4AZoning
3,050 sfGross Floor Area
2Units
Rent Stabilized0 Open Violations
Two family frame · 5,000 sf lot · 0.61 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Cellar2p · 2 filings · 17 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
S DECISION LLC103/22/2026
1908 HUNT AVE103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
09/11/2020$985K—— → —$323/sf building
04/12/2019$590K—— → —$193/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ROJAS ENGINEERING, PLLC409/20/2024
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MAMC CONSULTING REPS LLCGeneral Contractor303/21/2026
SKY ELECTRIC LLCElectrical103/22/2026
HUDSON RIVER MECH GROUP IPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ROJAS ENGINEERING PLLC6232409/20/2024
Building Lifecycle
All (5)Inspection (5)
01/28/2025
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
09/19/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
08/27/2024
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
07/18/2024
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
07/18/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offHUDSON RIVER MECH GROUP I07/05/2024
DOB NOWGeneral ConstructionSigned-offMAMC CONSULTING REPS LLC04/22/2024
1 project · most recent 05/22/2019
General Wiring
FiledStatusContractorScope
05/22/2019Permit IssuedSKY ELECTRIC LLCGeneral Wiring
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
01/28/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
09/19/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
08/27/2024Fail-Final PL - Up to 3 Requested FloorsFailView ↗
07/18/2024Certified Gas-Gas-Piping-RoughingCertifiedView ↗
07/18/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
09/24/2024Fire-Resistant Penetrations and JointsDarlyn Alvarezspecial
08/27/2024Fire-Resistant Penetrations and JointsDarlyn Alvarezspecial
12/19/2021Fire-Resistant Penetrations and JointsDarlyn Alvarezspecial
12/19/2021Energy Code Compliance InspectionsDarlyn Alvarezprogress
12/19/2021FinalDarlyn Alvarezprogress
▾Documents — 17 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/21/2026X00650512-I1Request digital key ↗
08/21/2026X00650512-P1Request digital key ↗
08/21/2026X00650512-P2Request digital key ↗
Showing 3 of 4 on file for this type
▸Zoning, Tax Lot & Property Records4
▸DOB NOWRestrictive Declaration/Easement 14
08/13/2026X00650512-P1Open ↗
08/13/2026X00650512-I1Open ↗
08/13/2026X00650512-P2Open ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications9
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/24/2026X00650509-I1Open ↗
08/21/2026X00650512-I1Open ↗
08/21/2026X00650512-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature3
08/28/2026X00650512-P1Open ↗
08/28/2026X00650509-I1Open ↗
08/23/2026X00650512-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/28/2026X00650509-I1Open ↗
08/28/2026X00650509-I1Open ↗