← Back
Predominantly retail with other uses
212-26 JAMAICA AVENUE
QUEENS · Queens Village · BIN 4238775
💬 Discuss this project
1920Year Built
2Stories
K4Building Class
C8-1Zoning
9,990 sfGross Floor Area
5Units
Rent Stabilized
Predominantly retail with other uses · Owner of record: PURA VIDA PARTNERS LLC · 7,875 sf lot · 1.27 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbingFire ProtectionGeneral
Roof2p · 1 filing · 16 docs
Floor 221p · 3 filings · 20 docs
Floor 140p · 5 filings · 20 docs
Cellar31p · 3 filings · 20 docs
Filed — no permit issued6p · 1 filing · 6 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
GERALD CALIENDO ARCHITECTS607/20/2026
BUILDING ENGINEERING SYSTEMS PLLC201/28/2026
BSA ENGINEERS1102/14/2025
Nothing on file for this building.
Nothing on file for this building.
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 11
DateTypeResultReport
04/21/2026Fail-Final CND-Occupancy InspectionFailView ↗
12/09/2025Pass-Final CND-Occupancy InspectionPassView ↗
10/29/2025Fail-Final CND-Occupancy InspectionFailView ↗
09/30/2024Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
09/30/2024Certified Sprinkler - SP - RoughingCertifiedView ↗
10/11/2023Pass-Final CND-Occupancy InspectionPassView ↗
07/17/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
07/10/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
10/07/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
08/01/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
07/21/2022Fail-Final PL - Up to 3 Requested FloorsFailView ↗
▾Special Inspection Requirements (DOB NOW) — 35
DateRequirementInspectorRole
06/01/2026Fire-Resistant Penetrations and JointsFAHAD FATEHspecial
06/01/2026Air barrier — testing FAHAD FATEHenergy_progress
06/01/2026Air barrier - visual inspectionFAHAD FATEHenergy_progress
06/01/2026Fire-Resistance Rated ConstructionFAHAD FATEHprogress
06/01/2026Energy Code Compliance InspectionsFAHAD FATEHprogress
06/01/2026Structural Stability – Alterations of existing buildingsFAHAD FATEHspecial
01/30/2026HVAC-R and service water heating system controlsSEBERT DYERenergy_progress
01/30/2026Maintenance informationSEBERT DYERenergy_progress
01/30/2026HVAC-R and service water heating equipmentSEBERT DYERenergy_progress
01/30/2026Mechanical SystemsSEBERT DYERspecial
01/30/2026Fire-Resistant Penetrations and JointsSEBERT DYERspecial
01/30/2026FinalSEBERT DYERprogress
01/30/2026Energy Code Compliance InspectionsSEBERT DYERprogress
01/30/2026HVAC-R and service water piping design and insulationSEBERT DYERenergy_progress
06/10/2025Public Assembly Emergency LightingFAHAD FATEHprogress
05/07/2025Public Assembly Emergency LightingFAHAD FATEHprogress
04/10/2025Fire-Resistant Penetrations and JointsFAHAD FATEHspecial
04/10/2025Structural Stability – Alterations of existing buildingsFAHAD FATEHspecial
04/10/2025Energy Code Compliance InspectionsFAHAD FATEHprogress
04/10/2025Fire-Resistance Rated ConstructionFAHAD FATEHprogress
04/10/2025Air barrier — testing FAHAD FATEHenergy_progress
04/10/2025Air barrier - visual inspectionFAHAD FATEHenergy_progress
01/09/2024Fire-Resistant Penetrations and JointsFAHAD FATEHspecial
01/09/2024Sprinkler SystemsFAHAD FATEHspecial
12/28/2023Fire-Resistant Penetrations and JointsFAHAD FATEHspecial
Latest 25 of 35.
Nothing on file for this building.