DOB03/09/2026BOROUGH COMMISSIONER HAS ORDERED ALL WORK STOPPED UNDERPERMIT# B01138719-I1 ON 3/6/26. CONSTRUCTION SUPERINTENDENT WITHDRAWAL. UNABLE TO DETERMINE PERCENTAGE OF WORK DUE TO NO ACCESS. STOP ALL WORK FOR JOB # REFERENCED AND MAKE THE SITE SAFE.
ECB04/28/2026RE-ISSUE 35720835L. AT THE TIME OF INSPECTION, THE FOLLOWING EMERGENCYLIGHTS WERE NOT OPERABLE:-BOX #3, #5, #2, #4, #9, 3 LIGHTS IN CAFETERIA. REMEDY: REPAIR AND/OR REPLACE.Nothing owed — awaiting certificate of correction
ECB04/28/2026FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AT THE TIME OF INSPECTION, ALL STAIRS ON THE 1ST FLOOR HAD STORAGE UNDER STAIRS. THE REAR ROOM IN CELLAR HAD LEAKS IN THE CEILING. STEP CRACKS WERE OBSERVENothing owed — awaiting certificate of correction
ECB04/28/2026FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. USE OF PROHIBITED DOOR AND/OR HARDWARE PER BC 1008.1.8; 27-371(J). AT THE TIME OF INSPECTION, THE FOLLOWING DOORS HAD TURN KNOB HANDLES:-101, 205, 207, 304Nothing owed — awaiting certificate of correction
ECB04/28/2026RE-ISSUE 35717406X. AT THE TIME OF INSPECTION, THERE WAS NO C OF O ON FILE FOR P. S. 86. REMEDY: OBTAIN VALID C OF O OR DISCONTINUE ILLEGAL OCCUPANCY.Nothing owed — awaiting certificate of correction
ECB08/14/2025REISSUE #35677517P. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. WATER PENETRATING THROUGH WALL AT BOILER ROOM PAINT POUR AND OTHER VARIOUS AREAS. REMEDY: REPAIRS AND/OR REPLACE.Nothing owed — awaiting certificate of correction
ECB08/14/2025FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. REISSUE 335717405Y. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. SEVERAL EMERGENCY LIGHTS THROUGHOUT THE BUILDING NOT WORKING WHEN TESTED. REMEDYNothing owed — awaiting certificate of correction
ECB08/14/2025REISSUE #35677516N. FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES. OBSERVED AT ROOF TOP BRICK TO CHIMNIES BUT MISSING BRICK ON ALL SIDE ALSO STOP CRACKS. REMEDY: REPAIR AND/OR REPLACE.Nothing owed — awaiting certificate of correction
ECB06/05/2025REISSUE #35677518R: FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER; ILLUMINATION FOR EXITS, EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1-27-381. ILLUMINATION EXITS NOT OPERATIONAL WHEN TESTED @ 1STNothing owed — awaiting certificate of correction
ECB06/05/2025ALTERED/CHANGED BUILDING OCCUPIED WITHOUT A VALID CERTIFICATE OF OCCUPANCY AS PER 28-118.3.1-28-118.3.2. 3 STORY BUILDING OCCUPIED AS PS 86 PUBLIC SCHOOL AND NO JOB RECORD SIGNED OFF OR RECORDS OF C OF O ON RECNothing owed — awaiting certificate of correction
ECB05/02/2024REISSUE #35672517M. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. ILLUMINATION FOR EXITS, EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1: 27-381. AT TIME OF MY INSPECTION I OBSERVED EMERGENCY LIGHTNothing owed — awaiting certificate of correction
ECB05/02/2024REISSUE #. FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES. AT TIME OF INSPECTION I OBSERVED AT THE ROOF TOP BRICK TO CHIMNIES BOTH MISSING BRICK ON ALL SIDE, ALSO AT EXIT 3" STEP CRACK APPROXIMATELY Y2X1Nothing owed — awaiting certificate of correction
ECB05/02/2024REISSUE #35672518Y. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AT TIME OF MY INSPECTION I OBSERVED WATER PENETRATION THROUGH THE WALL AT THE BOILER ROOM AND THE PAINT ROOM IN VARIOUS AREAS OF THE CNothing owed — awaiting certificate of correction
ECB03/14/2023FAILURE TO MAINTAIN BUILDING WALLS OR APPURTENANCES.NOTED AT ROOFTOP BRICK CHIMNIES BOTH MISSING BRICKS ON ALL SIDES.ALSO AT EXIT 3 STEP CRACK APPROX 1/2"X10'L IN THE EXTERIOR WALL.REMEDY:MAKE NECESSARY REPAIRSNothing owed — awaiting certificate of correction
ECB03/14/2023FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTED WATER PENETRATION THROUGH THE WALL AT BOILER ROOM,PAINT ROOM,AND VARIOUS OTHER AREAS OF CELLAR.ALSO AT ROOFTOP BULKHEAD STAIR C.REMEDY:MAKE NECESSARYNothing owed — awaiting certificate of correction
ECB03/14/2023REISSUE#35655077N FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.ILLUMINATION FOR EXITS,EXIT DISCHARGES AND PUBLIC CORRIDORS PER 1006.1;27-381.NOTED DEFECTIVE EMERGENCY EXIT LIGHTING AT 1ST FLOOR MAIN ENNothing owed — awaiting certificate of correction
ECB04/18/2022REISSUE#35557936N.FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.ILLUMINATION FOR EXITS,EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC1006.1;27-381 AT 1ST FLOOR FRONT MAIN ENTRANCE AND BASEMENT STAIR EMERGENothing owed — awaiting certificate of correction
ECB04/13/2021REISSUE#35486741H FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER ILLUMINATION FOR EXIT DISCHARGES & PUBLIC COORIDORS PER BC 1006-1-27-381EXIT LIGHT AT 1ST FL NEAR MAIN ENTRANCE & AT BASEMENT STAIR ENTRANCENothing owed — awaiting certificate of correction
ECB03/26/2020REISSUE #35383860Z FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER ILLUMINATION FOR EXIST EXIT DISCHARGES AND PUBLIC CORRIDOR PER BC 1006.1&27-381 EXIT LIGHT THROUGHOUT NOT WORKING REPAIR AND OR REPLACENothing owed — awaiting certificate of correction
ECB04/01/2019FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER ILLUMINATION FOREXITS,EXIT DISCHARGES AND PUBLIC CORRIDOR PER BC 1006.1;27-381. NOTED AT MULTI PURPOSE ROOM LEFT SIDE AND OUTSIDE CAFETERIA IN STAIRWAY C&DNothing owed — awaiting certificate of correction
ECB03/07/2018OPERATION OF A PLACE OF ASSEMBLY W/O A CURRENT C OF O. NOTED: AT CAFETERIA AREA,NO PLACE OF ASSEMBLY C W/O SIGN. REMEDY: COMPLY W/CODE/OBTAIN A PLACE OF ASSEMBLY C OF O.Nothing owed — awaiting certificate of correction