← Back
Old law tenement
213 EAST 10 STREET
MANHATTAN · East Village · BIN 1006466
💬 Discuss this project
1900Year Built
5Stories
C4Building Class
R8BZoning
8,940 sfGross Floor Area
20Units
Rent Stabilized12 Open Violations 10 unresolved · 2 paperwork only ▸
Old law tenement · Owner of record: RENTAL APARTMENTS · 2,369 sf lot · 3.77 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralPlumbingGeneral
Floor 37p · 1 filing · 8 docs
Floor 27p · 1 filing · 8 docs
Floor 1
Filed — no permit issued4p · 1 filing · 3 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
RENTAL APARTMENTS303/22/2026
NEW YORK REALTY MANAGEMENT303/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ATELIER NEW YORK ARCHITECTURE209/23/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
ATELIER NEW YORK ARCHITECTURE203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
OVERALL RENOVATION INCGeneral Contractor303/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ATELIER NY ARCHITECTURE2438109/23/2021
GREYSTONE ENGINEERING CON2973109/23/2021
Building Lifecycle
All (38)Filed (2)Violation (25)Special Inspection (11)
04/01/2024
Violation issued (HPD, closed)
A
11/15/2023
Violation issued (HPD, closed)
I
09/23/2021
Filed — Alteration
INTERIOR RENOVATION TO COMBINE APARTMENTS 6 & 10 INTO 610. PLUMBING WORK AS PER PLANS. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
M00597063-I1
09/23/2021
Filed — Alteration
INTERIOR RENOVATION TO COMBINE APARTMENTS 6 & 10 INTO 610. PARTITION CHANGES TO NON-LOAD-BEARING WALLS, STRUCTURAL WORK AND MINOR MECHANICAL WORK AS PER PLANS. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
M00585480-I1
09/22/2021
Special inspection requirement — Lighting in dwelling units
Kenneth Hudes
09/22/2021
Special inspection requirement — Fenestration and door U-factor and product ratings
Kenneth Hudes
09/22/2021
Special inspection requirement — Fenestration air leakage
Kenneth Hudes
09/22/2021
Special inspection requirement — Air barrier - visual inspection
Kenneth Hudes
09/22/2021
Special inspection requirement — Electrical motors and elevators
Kenneth Hudes
09/22/2021
Special inspection requirement — Fenestration areas
Kenneth Hudes
09/20/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
Kenneth Hudes
09/20/2021
Special inspection requirement — Energy Code Compliance Inspections
Kenneth Hudes
09/20/2021
Special inspection requirement — Structural Wood Frame
TIMOTHY TWEEDY
08/30/2021
Special inspection requirement — Final
Kenneth Hudes
08/30/2021
Special inspection requirement — Structural Stability – Alterations of existing buildings
TIMOTHY TWEEDY
10/05/2018
Violation issued (HPD, closed)
I
10/24/2016
Violation issued (HPD, closed)
I
02/13/2004
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/19/2003
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/26/2002
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/02/2001
Violation issued (DOB, open)
VW-VIOLATION WORK WITHOUT PERMIT - ACTIVE
03/02/2001
Violation issued (ECB, open)
Construction
02/27/2001
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/07/2000
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/16/1999
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
10/27/1998
Violation issued (ECB, open)
Construction
05/04/1998
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/16/1997
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/10/1997
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
04/22/1996
Violation issued (HPD, open)
C
08/29/1995
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
03/22/1994
Violation issued (HPD, open)
B
03/18/1994
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
08/26/1993
Violation issued (HPD, open)
C
03/18/1993
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
12/22/1988
Violation issued (HPD, open)
C
12/22/1988
Violation issued (HPD, open)
C
12/22/1988
Violation issued (HPD, open)
C
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
BISOTISSUEDBAVARIA CONSTRUCTION CORP10/28/1999
BISOTISSUEDMID TOWN CONST.&DEVELOPMENY CORP08/03/1993
1 project · most recent 09/23/2021
Gas Water/Sanitary
FiledStatusContractorScope
09/23/2021——Gas, Water/Sanitary
1 project · most recent 09/23/2021
Wood
FiledStatusContractorScope
09/23/2021——Wood
▾Special Inspection Requirements (DOB NOW) — 11
DateRequirementInspectorRole
09/22/2021Lighting in dwelling unitsKenneth Hudesenergy_progress
09/22/2021Fenestration and door U-factor and product ratingsKenneth Hudesenergy_progress
09/22/2021Fenestration air leakageKenneth Hudesenergy_progress
09/22/2021Air barrier - visual inspectionKenneth Hudesenergy_progress
09/22/2021Electrical motors and elevatorsKenneth Hudesenergy_progress
09/22/2021Fenestration areasKenneth Hudesenergy_progress
09/20/2021Fire-Resistant Penetrations and JointsKenneth Hudesspecial
09/20/2021Energy Code Compliance InspectionsKenneth Hudesprogress
09/20/2021Structural Wood FrameTIMOTHY TWEEDYprogress
08/30/2021FinalKenneth Hudesprogress
08/30/2021Structural Stability – Alterations of existing buildingsTIMOTHY TWEEDYspecial
▾Documents — 11 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
09/03/2026M00585480-I1Request digital key ↗
09/03/2026M00597063-I1Request digital key ↗
▸Seals & Professional Certifications7
▸DOB NOWProgress Inspector Seal & Signature3
08/24/2026M00585480-I1Open ↗
08/24/2026M00585480-I1Open ↗
08/24/2026M00585480-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature2
09/03/2026M00585480-I1Open ↗
09/03/2026M00597063-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/24/2026M00585480-I1Open ↗
08/24/2026M00585480-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
09/03/2026M00585480-I1Open ↗
09/03/2026M00597063-I1Open ↗