← Back
Primarily 1 family with 1 store or office
214-04 46 ROAD
QUEENS · BIN 4157614
💬 Discuss this project
1950Year Built
2Stories
S1Building Class
R4BZoning
1,600 sfGross Floor Area
2Units
Primarily 1 family with 1 store or office · Owner of record: TAI HUA REALTY LLC · 1,993 sf lot · 0.8 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Floor 210p · 1 filing · 20 docs
Floor 110p · 1 filing · 20 docs
Cellar10p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
TAI HUA REALTY LLC1503/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
09/26/2024$971K—Private party → TAI HUA REALTY LLC$607/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
MEI ARCHITECT PLLC205/31/2025
MEHDI GHAZI, P.E., P.C.303/21/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
ALPHA HOME DESIGN LLC1003/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
L&L CONSTRUCTION DEVELOPGeneral Contractor303/21/2026
ROCK E SMALL PLBG&HTG INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
MEHDI GHAZI, P.E. P.C.7129505/31/2025
Building Lifecycle
All (36)Filed (5)Permit Issued (2)Signed Off (2)Inspection (10)Special Inspection (17)
01/21/2026
Inspection — Fail-Final CND-Occupancy Inspection
Fail
View inspection ↗
12/29/2025
Inspection — Fail-Final CND-Occupancy Inspection
Fail
View inspection ↗
12/04/2025
Inspection — Fail-Final CND-Occupancy Inspection
Fail
View inspection ↗
10/31/2025
Inspection — Fail-Final CND-Occupancy Inspection
Fail
View inspection ↗
07/21/2025
Signed off — Alteration CO
PROPOSED CONVERSION FROM ONE-OFFICE & ONE-FAMILY TO TWO-FAMILY DWELLING UNITS. INTERIOR RENOVATION AS PER PLAN FILED HEREWITH. OBTAIN A NEW CERTIFICATE OF OCCUPANCY.
Q01145436-I1
06/25/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
06/24/2025
Signed off — Alteration CO
PROPOSED CONVERSION FROM ONE-OFFICE & ONE-FAMILY TO TWO-FAMILY DWELLING UNITS. INTERIOR RENOVATION AS PER PLAN FILED HEREWITH. OBTAIN A NEW CERTIFICATE OF OCCUPANCY.
Q01145436-S1
06/18/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
MEHDI GHAZI
06/18/2025
Special inspection requirement — Fire-Resistance Rated Construction
MEHDI GHAZI
06/18/2025
Special inspection requirement — Energy Code Compliance Inspections
MEHDI GHAZI
06/18/2025
Special inspection requirement — Insulation placement and R values
MEHDI GHAZI
06/18/2025
Special inspection requirement — Interior lighting power
MEHDI GHAZI
06/18/2025
Special inspection requirement — Metering
MEHDI GHAZI
06/18/2025
Special inspection requirement — Permanent certificate
MEHDI GHAZI
05/31/2025
Filed — Alteration CO
PROPOSED CONVERSION FROM ONE-OFFICE & ONE-FAMILY TO TWO-FAMILY DWELLING UNITS. INTERIOR RENOVATION AS PER PLAN FILED HEREWITH. OBTAIN A NEW CERTIFICATE OF OCCUPANCY.
Q01145436-P3
03/25/2025
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
03/25/2025
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
03/25/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
03/25/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
03/21/2025
Filed — Alteration CO
PROPOSED CONVERSION FROM ONE-OFFICE & ONE-FAMILY TO TWO-FAMILY DWELLING UNITS. INTERIOR RENOVATION AS PER PLAN FILED HEREWITH. OBTAIN A NEW CERTIFICATE OF OCCUPANCY.
Q01145436-P2
03/21/2025
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
03/21/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
MEHDI GHAZI
03/21/2025
Special inspection requirement — Energy Code Compliance Inspections
MEHDI GHAZI
03/21/2025
Special inspection requirement — HVAC-R and service water heating system controls
MEHDI GHAZI
03/21/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
MEHDI GHAZI
03/21/2025
Special inspection requirement — HVAC-R and service water heating equipment
MEHDI GHAZI
03/20/2025
Filed — Alteration CO
PROPOSED CONVERSION FROM ONE-OFFICE & ONE-FAMILY TO TWO-FAMILY DWELLING UNITS. INTERIOR RENOVATION AS PER PLAN FILED HEREWITH. OBTAIN A NEW CERTIFICATE OF OCCUPANCY.
Q01145436-P1
03/14/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
MEHDI GHAZI
03/14/2025
Special inspection requirement — Energy Code Compliance Inspections
MEHDI GHAZI
03/14/2025
Special inspection requirement — HVAC-R and service water heating equipment
MEHDI GHAZI
03/14/2025
Special inspection requirement — HVAC-R and service water heating system controls
MEHDI GHAZI
03/14/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
MEHDI GHAZI
01/22/2025
Permit issued — Plumbing
Q01145436-S1-PL
01/17/2025
Permit issued — General Construction
Q01145436-I1-GC
01/13/2025
Filed — Alteration CO
PROPOSED CONVERSION FROM ONE-OFFICE & ONE-FAMILY TO TWO-FAMILY DWELLING UNITS. INTERIOR RENOVATION AS PER PLAN FILED HEREWITH. OBTAIN A NEW CERTIFICATE OF OCCUPANCY.
Q01145436-S1
11/21/2024
Filed — Alteration CO
PROPOSED CONVERSION FROM ONE-OFFICE & ONE-FAMILY TO TWO-FAMILY DWELLING UNITS. INTERIOR RENOVATION AS PER PLAN FILED HEREWITH. OBTAIN A NEW CERTIFICATE OF OCCUPANCY.
Q01145436-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offROCK E SMALL PLBG&HTG INC01/22/2025
DOB NOWGeneral ConstructionPermit IssuedL&L CONSTRUCTION DEVELOP01/17/2025
1 project · most recent 05/31/2025
Gas Storm Water/Sanitary
FiledStatusContractorScope
05/31/2025Signed-offROCK E SMALL PLBG&HTG INCGas, Storm, Water/Sanitary
1 project · most recent 03/06/2025
General Wiring
FiledStatusContractorScope
03/06/2025CompleteKJK ELECTRIC INCGeneral Wiring
▾Field Inspections (DOB CAP) — 10
DateTypeResultReport
01/21/2026Fail-Final CND-Occupancy InspectionFailView ↗
12/29/2025Fail-Final CND-Occupancy InspectionFailView ↗
12/04/2025Fail-Final CND-Occupancy InspectionFailView ↗
10/31/2025Fail-Final CND-Occupancy InspectionFailView ↗
06/25/2025Pass-Final CND-Occupancy InspectionPassView ↗
03/25/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
03/25/2025Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
03/25/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
03/25/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
03/21/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 17
DateRequirementInspectorRole
06/18/2025Fire-Resistant Penetrations and JointsMEHDI GHAZIspecial
06/18/2025Fire-Resistance Rated ConstructionMEHDI GHAZIprogress
06/18/2025Energy Code Compliance InspectionsMEHDI GHAZIprogress
06/18/2025Insulation placement and R valuesMEHDI GHAZIenergy_progress
06/18/2025Interior lighting powerMEHDI GHAZIenergy_progress
06/18/2025MeteringMEHDI GHAZIenergy_progress
06/18/2025Permanent certificateMEHDI GHAZIenergy_progress
03/21/2025Fire-Resistant Penetrations and JointsMEHDI GHAZIspecial
03/21/2025Energy Code Compliance InspectionsMEHDI GHAZIprogress
03/21/2025HVAC-R and service water heating system controlsMEHDI GHAZIenergy_progress
03/21/2025HVAC-R and service water piping design and insulationMEHDI GHAZIenergy_progress
03/21/2025HVAC-R and service water heating equipmentMEHDI GHAZIenergy_progress
03/14/2025Fire-Resistant Penetrations and JointsMEHDI GHAZIspecial
03/14/2025Energy Code Compliance InspectionsMEHDI GHAZIprogress
03/14/2025HVAC-R and service water heating equipmentMEHDI GHAZIenergy_progress
03/14/2025HVAC-R and service water heating system controlsMEHDI GHAZIenergy_progress
03/14/2025HVAC-R and service water piping design and insulationMEHDI GHAZIenergy_progress
▾Documents — 38 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
08/20/2026Q01145436-S1Request digital key ↗
08/20/2026Q01145436-P3Request digital key ↗
08/20/2026Q01145436-P2Request digital key ↗
Showing 3 of 5 on file for this type
▸Zoning, Tax Lot & Property Records2
▸DOB NOWHouse Number Verification: TOPO Stamp2
08/13/2026Q01145436-I1Open ↗
08/13/2026Q01145436-P3Open ↗
▸Seals & Professional Certifications22
▸DOB NOWProgress Inspector Seal & Signature14
09/26/2026Q01145436-I1Open ↗
09/26/2026Q01145436-I1Open ↗
09/26/2026Q01145436-I1Open ↗
Showing 3 of 14 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/13/2026Q01145436-P3Open ↗
08/13/2026Q01145436-S1Open ↗
08/13/2026Q01145436-P1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature3
09/26/2026Q01145436-I1Open ↗
09/01/2026Q01145436-P2Open ↗
09/01/2026Q01145436-P1Open ↗
▸Safety & Tenant Protection2
▸DOB NOWStreet Tree Checklist2
08/13/2026Q01145436-I1Open ↗
08/13/2026Q01145436-P3Open ↗
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/13/2026Q01145436-P2Open ↗
08/13/2026Q01145436-I1Open ↗
08/13/2026Q01145436-P3Open ↗
Showing 3 of 5 on file for this type
▸Other Documents2
▸DOB NOWProperty Ownership Certification2
08/13/2026Q01145436-I1Open ↗
08/13/2026Q01145436-P3Open ↗