← Back
Three families
214-04 HILLSIDE AVENUE
QUEENS · Queens Village · BIN 4228711
💬 Discuss this project
1960Year Built
2Stories
C0Building Class
R2Zoning
2,152 sfGross Floor Area
3Units
Rent Stabilized4 Open Violations ▸FDNY Report ↗
Three families · 2,200 sf lot · 0.98 FAR built · Flood zone X
Locations of Work
Architecture
Floor 13p · 1 filing · 9 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
KATARIA607/08/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
03/31/2022$860K—Private party → Private party$400/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
EDWARD C. HICKS RA205/14/2024
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
YAFE MEOD CORPGeneral Contractor107/08/2026
Building Lifecycle
All (29)Filed (2)Permit Issued (1)Violation (6)Inspection (1)Objection (10)Special Inspection (9)
11/25/2025
Violation issued (HPD, open)
I
03/20/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
12/05/2024
Violation issued (HPD, open)
I
05/24/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
05/24/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
05/23/2024
Objection raised — Inspections
05/23/2024
Objection resolved — Addressed
05/23/2024
Objection raised — Fire_Protection
05/23/2024
Objection resolved — Addressed
05/20/2024
Permit issued — General Construction
Q00977526-I1-GC
05/14/2024
Filed — Alteration
FILING HEREWITH PLANS AND APPLICATION FOR INTERIOR RENOVATIONS TO EXISTING TWO FAMILY DWELLING. PROVIDE NEW HOME OCCUPATION OFFIE FOR A DOCTOR HOME OFFICE ON FIRST FLOOR UNIT. RESTORE GARAGE BACK TO LEGAL CONDITIONS. VIEW SEPARATE APP FOR PLUMBING.
Q00977526-S1
05/14/2024
Special inspection requirement — Energy Code Compliance Inspections
01/07/2024
Objection resolved — Addressed
01/07/2024
Objection resolved — Addressed
01/07/2024
Objection resolved — Addressed
12/28/2023
Objection raised — Other
12/28/2023
Objection raised — Inspections
12/28/2023
Objection raised — Other
12/14/2023
Filed — Alteration
FILING HEREWITH PLANS AND APPLICATION FOR INTERIOR RENOVATIONS TO EXISTING TWO FAMILY DWELLING. PROVIDE NEW HOME OCCUPATION OFFIE FOR A DOCTOR HOME OFFICE ON FIRST FLOOR UNIT. RESTORE GARAGE BACK TO LEGAL CONDITIONS. VIEW SEPARATE APP FOR PLUMBING.
Q00977526-I1
12/14/2023
Special inspection requirement — Insulation placement and R values
EDWARD HICKS
12/14/2023
Special inspection requirement — Energy Code Compliance Inspections
EDWARD HICKS
12/14/2023
Special inspection requirement — Interior lighting power
EDWARD HICKS
12/14/2023
Special inspection requirement — Fenestration and door U-factor and product ratings
EDWARD HICKS
12/14/2023
Special inspection requirement — Fire-Resistance Rated Construction
EDWARD HICKS
12/14/2023
Special inspection requirement — Final
EDWARD HICKS
11/29/2023
Violation issued (HPD, open)
I
11/18/2022
Violation issued (HPD, open)
I
04/22/2021
Violation issued (HPD, closed)
I
09/13/1999
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedYAFE MEOD CORP05/20/2024
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 1
DateTypeResultReport
03/20/2025Pass-Final CND-Occupancy InspectionPassView ↗
▾Special Inspection Requirements (DOB NOW) — 9
DateRequirementInspectorRole
05/24/2024Fire-Resistant Penetrations and Joints—special
05/24/2024HVAC-R and service water piping design and insulation—energy_progress
05/14/2024Energy Code Compliance Inspections—progress
12/14/2023Insulation placement and R valuesEDWARD HICKSenergy_progress
12/14/2023Energy Code Compliance InspectionsEDWARD HICKSprogress
12/14/2023Interior lighting powerEDWARD HICKSenergy_progress
12/14/2023Fenestration and door U-factor and product ratingsEDWARD HICKSenergy_progress
12/14/2023Fire-Resistance Rated ConstructionEDWARD HICKSprogress
12/14/2023FinalEDWARD HICKSprogress
▾Documents — 7 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/22/2026Q00977526-S1Request digital key ↗
08/22/2026Q00977526-I1Request digital key ↗
▸Seals & Professional Certifications4
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/22/2026Q00977526-S1Open ↗
08/22/2026Q00977526-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/29/2026Q00977526-I1Open ↗
08/29/2026Q00977526-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/22/2026Q00977526-S1Open ↗